Where allowed to run: All environments (*ALL) Threadsafe: No |
Parameters Examples Error messages |
The Create Controller Description (Virtual Work Station) (CRTCTLVWS) command creates a controller description for a virtual work station (pass-through) controller. For more information about using this command, see the Communications Configuration book, SC41-5401.
Top |
Keyword | Description | Choices | Notes |
---|---|---|---|
CTLD | Controller description | Name | Required, Positional 1 |
ONLINE | Online at IPL | *YES, *NO | Optional |
TEXT | Text 'description' | Character value, *BLANK | Optional |
DEV | Attached devices | Values (up to 255 repetitions): Name | Optional |
DEVWAITTMR | Device wait timer | 2-120, 20 | Optional |
MSGQ | Message queue | Single values: *SYSVAL, *SYSOPR Other values: Qualified object name |
Optional |
Qualifier 1: Message queue | Name | ||
Qualifier 2: Library | Name | ||
AUT | Authority | Name, *CHANGE, *ALL, *USE, *EXCLUDE, *LIBCRTAUT | Optional |
Top |
This is a required parameter.
Specifies the name of the controller description.
Top |
Specifies whether this object is automatically varied on at initial program load (IPL).
The controller is automatically varied on at IPL.
The controller is not automatically varied on at IPL.
Top |
Specifies the text that briefly describes the object.
No text is specified.
Specify no more than 50 characters of text, enclosed in apostrophes.
Top |
Specifies the names of the devices that are attached to this controller. The device descriptions must already exist.
A maximum of 255 devices can be specified.
Top |
Specifies the device wait timeout value. This is used to limit the amount of time that a subsystem takes for the work station input/output to complete. The timeout value that is used for each device is obtained from the controller that it is attached to at vary on time. A change in this parameter value takes effect for attached devices when they are next varied on.
For local controllers, the subsystem waits a maximum of 10 seconds for the completion of the input/output of each work station attached to this controller.
Specify a value ranging from 2 through 600 that specifies the maximum number of seconds that the subsystem waits for work station input/output to complete for all work stations attached to this controller.
When selecting a value for this parameter, the types of devices attached to the controller should be taken into account. Locally attached work stations should have a low value for this parameter (10 seconds or less).
Top |
Specifies the message queue to which operational messages are sent.
Qualifier 1: Message queue
Qualifier 2: Library
For more information about using this command, see the Communcations Management book, SC41-5406.
Top |
Specifies the authority you are giving to users who do not have specific authority for the object, who are not on an authorization list, and whose group profile or supplemental group profiles do not have specific authority for the object.
Top |
CRTCTLVWS CTLD(VRTCTL325) TEXT('S/325 virtual controller')
This command creates a controller description named VRTCTL325.
Top |
*ESCAPE Messages