Where allowed to run: All environments (*ALL) Threadsafe: No |
Parameters Examples Error messages |
The Change Device Description (BSC) (CHGDEVBSC) command changes a device description for a binary synchronous communications (BSC) device.
Top |
Keyword | Description | Choices | Notes |
---|---|---|---|
DEVD | Device description | Name | Required, Key, Positional 1 |
LOCADR | Local location address | *SAME, 00, 01, 02, 03, 04, 05, 06, 07, 08, 09, 0A, 0B, 0C, 0D, 0E, 0F, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 2A, 2B, 2C, 2D, 2E, 2F, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 3A, 3B, 3C, 3D, 3E, 3F, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 4A, 4B, 4C, 4D, 4E, 4F, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 5A, 5B, 5C, 5D, 5E, 5F, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D, 6E, 6F, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 7A, 7B, 7C, 7D, 7E, 7F, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 8A, 8B, 8C, 8D, 8E, 8F, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 9A, 9B, 9C, 9D, 9E, 9F, A0, A1, A2, A3, A4, A5, A6, A7, A8, A9, AA, AB, AC, AD, AE, AF, B0, B1, B2, B3, B4, B5, B6, B7, B8, B9, BA, BB, BC, BD, BE, BF, C0, C1, C2, C3, C4, C5, C6, C7, C8, C9, CA, CB, CC, CD, CE, CF, D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, DA, DB, DC, DD, DE, DF, E0, E1, E2, E3, E4, E5, E6, E7, E8, E9, EA, EB, EC, ED, EE, EF, F0, F1, F2, F3, F4, F5, F6, F7, F8, F9, FA, FB, FC, FD, FE | Optional |
ONLINE | Online at IPL | *SAME, *YES, *NO | Optional |
CTNWIN | Contention resolution winner | *SAME, *SEC, *PRI | Optional |
BLOCK | Blocking type | *SAME, *NONE, *ITB, *IRS, *NOSEP, *USER, *SEP | Optional |
SEPCHAR | Separator character | *SAME, 00, 04, 05, 06, 07, 08, 09, 0A, 0B, 0C, 0D, 0E, 0F, 11, 12, 13, 14, 15, 16, 17, 18, 19, 1A, 1B, 1C, 1E, 20, 21, 22, 23, 24, 25, 27, 28, 29, 2A, 2B, 2C, 2E, 2F, 30, 31, 33, 34, 35, 36, 38, 39, 3A, 3B, 3C, 3E, 3F, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 4A, 4B, 4C, 4D, 4E, 4F, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 5A, 5B, 5C, 5D, 5E, 5F, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D, 6E, 6F, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 7A, 7B, 7C, 7D, 7E, 7F, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 8A, 8B, 8C, 8D, 8E, 8F, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 9A, 9B, 9C, 9D, 9E, 9F, A0, A1, A2, A3, A4, A5, A6, A7, A8, A9, AA, AB, AC, AD, AE, AF, B0, B1, B2, B3, B4, B5, B6, B7, B8, B9, BA, BB, BC, BD, BE, BF, C0, C1, C2, C3, C4, C5, C6, C7, C8, C9, CA, CB, CC, CD, CE, CF, D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, DA, DB, DC, DD, DE, DF, E0, E1, E2, E3, E4, E5, E6, E7, E8, E9, EA, EB, EC, ED, EE, EF, F0, F1, F2, F3, F4, F5, F6, F7, F8, F9, FA, FB, FC, FD, FE, FF | Optional |
RMTBSCEL | Remote BSCEL | *SAME, *NO, *YES | Optional |
RCDLEN | Record length | 1-8192, *SAME | Optional |
BLKLEN | Block length | 1-8192, *SAME | Optional |
TRNSPY | Transmit in transparent mode | *SAME, *YES, *NO | Optional |
DTACPR | Compress and decompress data | *SAME, *YES, *NO | Optional |
TRUNC | Truncate trailing blanks | *SAME, *YES, *NO | Optional |
GRPSEP | Group separator type | *SAME, *EOT, *OFCSYS, *DEV3740 | Optional |
EMLDEV | Emulated device | *SAME, 3278, 3284, 3286, 3287, 3288, 3289 | Optional |
EMLKBD | Emulated keyboard | *SAME, *UPPER, *LOWER | Optional |
EMLNUMLCK | Emulated numeric lock | *SAME, *YES, *NO | Optional |
EMLWRKSTN | Emulation work station | Name, *SAME, *ANY | Optional |
TEXT | Text 'description' | Character value, *SAME, *BLANK | Optional |
Top |
Specifies the name of the device description being changed.
This is a required parameter.
Top |
Specifies the local location address for this device.
Valid values range from 00 to FE.
Top |
Specifies whether this object is automatically varied on at initial program load (IPL).
Top |
Specifies which BSC station will gain control when line contention occurs.
Top |
Specifies if the system or user blocks and deblocks transmitted records.
Top |
Specifies a unique one-byte record separator character.
Valid values range from 00 to FF; BSC control characters are not allowed.
Top |
Specifies the type of BSCEL session with the remote system.
Top |
Specifies the maximum record length allowed when communicating with this device.
The value must be at least the size of the largest record to be sent, but must not exceed the buffer size specified on the line description (MAXBUFFER parameter) to which this device is attached.
Top |
Specifies the maximum block length allowed when communicating with this device.
The value must be at least the size of the largest record to be sent, but must not exceed the buffer size specified on the line description (MAXBUFFER parameter) to which this device is attached.
Note: This parameter is valid only if APPTYPE(*BSCEL) or APPTYPE(*RPGT) is specified.
Top |
Specifies whether the text transparency feature is used when sending blocked records. This feature permits the transmission of all 256 EBCDIC character codes; you should use this feature when transmitting packed or binary data fields.
Top |
Specifies whether data compression is performed.
Note: DTACPR(*YES) cannot be specified if TRNSPY(*YES) or TRUNC(*YES) is specified. This parameter is valid only if APPTYPE(*BSCEL) or APPTYPE(*RPGT) is specified.
Top |
Specifies whether trailing blanks are removed from output records.
Top |
Specifies a separator for groups of data, such as data sets and documents.
Top |
Specifies that this program device entry is used to send and receive 3270 data streams. The emulation device parameter consists of an emulation device type and an emulation device data format. The emulation device data format specifies the format of the type 3270 data stream being sent or received. A 20- or 32-byte common header that contains type 3270 command and data flow information is located at the start of the I/O buffer that is sending or receiving the type 3270 data stream. This parameter applies only to SNUF communications. This parameter can be specified as a list of two values (elements) or as a single value (*NONE).
Top |
Specifies the type of 3278 display keyboard that is emulated. This parameter is valid only when *EML is specified for the Application type (APPTYPE) parameter.
Top |
Specifies whether numeric input fields only allow numeric data on a 5250 keyboard. The value can be specified for this parameter only if *EML is specified for the Application type (APPTYPE) parameter.
Top |
The emulation work station associates an emulation device with a real display or printer device. The device address is reserved for use exclusively by that work station. If no device or *ANY is specified, any work station can use the emulation device.
Top |
Top |
CHGDEVBSC DEVD(BSC001) EMLDEV(3278) EMLKBD(*LOWER)
This command changes the device description for the BSC device named BSC001 so it emulates a 3278 display station with both uppercase and lowercase characters.
Top |