1 | Session handle | Input | Binary(4) |
2 | Input buffer handle | Input | Binary(4) |
3 | CCSID | Input | Binary(4) |
4 | Number of bytes read | Output | Binary(4) |
5 | Error code | I/O | Char(*) |
Number of bytes read | Output | Binary(4) |
The Read Data from Session with CCSID (QsnReadSsnDtaCC) API is used to read data from a session. A QsnReadInp operation is implicitly performed to read any field data. If the session has a DSM-defined input line, an implicit Clear Field Table (QsnClrFldTbl) operation is issued prior to redefining the session input line on each input operation. The data returned consists of only the data entered. That is, only the data from the cursor position within the field up to the last nonblank input character when an AID generating key is pressed is returned. If the session does not have a DSM-defined input line, data is read from any input fields defined on the screen, and all data, including blanks, is returned. In other respects, the processing of these user-defined input fields will be equivalent with the processing of the DSM-defined input line.
If the previous input operation was a call to QsnReadSsnDta, the session input line will be changed to support the CCSID requested.
If an AID key is pressed for which a corresponding function has been defined, this function will be called. Depending upon the return action specified, control would then return to the caller or another input operation will occur. See Command Key Action Routines for details.
This command is not supported by all control units. A CPFA306 error occurs if an attempt is made to issue this command to a control unit that does not support it.
The CCSID value given must be supported by the device or emulator, otherwise a CPF3BDE will be signaled.
If the device supports CCSID-based I/O and the session was not defined with an input line and the application defines input fields on the screen, DSM is not able to determine if the fields are CCSID-capable or what the CCSID is. Since CCSID-based data requires special datastream commands, DSM could send invalid data to the device, or otherwise corrupt or misinterpret the input data. Because of this, the data read from any application defined input fields on the screen will not be echoed to the scroller. Also, the default command key exit routines will not use this data.
None
A handle for the session from which to read input. The session being read from must be the current window. You can use the Set Current Window (QsnSetCurWin) API to change the current window.
A handle for the input buffer to receive the result of the input operations if a direct operation is specified. The input buffer must have been created with the Create Input Buffer (QsnCrtInpBuf) API. The format of the data returned is the same as that of the Read Input Fields (QsnReadInp) API.
The CCSID of the data to read. The session input line will be changed to support a CCSID-based read, unless a previous QsnReadSsnDtaCC was performed for this CCSID.
If the CCSID given is not supported by the device, a CPF3BDE is signaled.
If this parameter is omitted (zero is passed in as the CCSID), the job CCSID is used. If the job CCSID is 65535, the default job CCSID is used instead.
The number of bytes of data read. On a successful read operation, this value is the same as that returned by the Retrieve Length of Field Data in Buffer (QsnRtvFldDtaLen) API if passed the input buffer resulting from this operation.
The structure in which to return error information. For the format of the structure, see Error Code Parameter. If this parameter is omitted, diagnostic and escape messages are issued to the application.
This API returns the value for the number of bytes read parameter if the operation was successful, -1 if there was a general failure, or -2 if the invite active flag is on in the associated environment and the read from invited device operation timed out.
Message ID | Error Message Text |
---|---|
CPF24B4 E | Severe error while addressing parameter list. |
CPF3BDE E | CCSID &1 not supported by API. |
CPF3CF1 E | Error code parameter not valid. |
CPF3CF2 E | Error(s) occurred during running of &1 API. |
CPFA31E E | Required parameter &1 omitted. |
CPFA343 E | Output operation not done. |
CPFA344 E | The file &2 in library &3 is not valid. |
CPFA345 E | The invite active flag is not valid. |
CPFA3A4 E | Specified window is not active. |
CPFA3D6 E | Session handle is incorrect. |
CPFA3D9 E | Error calling the command key action routine. |
For examples of Read Data from Session APIs, see Create Session and Read Data--Example.
Top | Dynamic Screen Manager APIs | APIs by category |