Build Separator Pages (QSPBSEPP) API


  Required Parameter Group:

1 Receiver variable Output Char(*)
2 Length of receiver variable Input Binary(4)
3 Format name Input Char(8)
4 Printer device name Input Char(10)
5 Printer data stream type Input Char(10)
6 Type of separator page Input Char(10)
7 Qualified name of separator page program Input Char(20)
8 Writer handle Input Char(16)
9 Spooled file handle Input Char(10)
10 Drawer for separator page Input Binary(4)
11 Error code I/O Char(*)

  Default Public Authority: *USE

  Threadsafe: No

The Build Separator Pages (QSPBSEPP) API builds the system separator page to be printed for the spooled file. A user exit program is called to build the separator page or the system default is used. The separator page is returned in the receiver variable parameter. This data can then be sent to the printer. This API is only valid when called from a program that was called by a printer writer program. This API is not valid when called from a program that was called by a remote writer program.

If Build Separator Pages (QSPBSEPP) API encounters a problem when running a separator exit program, the default system separator will be returned. No error will be signalled or returned in the error code parameter.


Authorities and Locks

If a qualified separator page program is specified or implied the user must have *EXECUTE authority to the program and the library the program is stored in.

The user must have *USE authority to the printer device description.


Required Parameter Group

Receiver variable
OUTPUT; CHAR(*)

The receiver variable that receives the information requested. You can specify the size of the area to be smaller than the format requested as long as you specify the length parameter correctly. As a result, the API returns only the data that the area can hold.

Length of receiver variable
INPUT; BINARY(4)

The length of the receiver variable. The amount of data is truncated if the receiver variable is too small. Anything less than 8 bytes is not valid.

Format name
INPUT; CHAR(8)

The format of the information returned in the receiver variable.

The valid format name is:

SEPP0100 The formatted separator page data.

Printer device name
INPUT; CHAR(10)

The name of the printer device description for the writer that was started.

Print data stream type
INPUT; CHAR(10)

The type of data stream recognized by the printer writer. This is used to determine the type of data to generate for the separator page.

The valid special value is:

*SCS Systems Network Architecture (SNA) character string

Type of separator
INPUT; CHAR(10)

The type of separator page to be built.

Valid values are:

*FILE A file separator page is returned in the separator page data. This separator is printed before each copy of a spooled file.
*JOB A job separator page is returned in the separator page data. This separator is printed between spooled files created by different jobs.

Qualified name of separator page program
INPUT; CHAR(20)

The name of the separator page exit program to use to build the separator page. The first 10 characters contain the separator page program name and the second 10 characters contain the name of the library in which the separator page program is located.

The following special values are supported for the program name:

*SYSDFT The system default separator page is generated.
*DEVD The separator program specified in the device description for the printer is used.

The following special values are supported for the library name:

*LIBL The library list of the writer job is used to locate the message file.
*CURLIB The current library for the writer job is used to locate the message file.

Writer handle
INPUT;CHAR(16)

The handle to the writer job. This handle is provided to the driver program on a writer call to the driver exit program at initialization time (the initialize option).

Spooled file handle
INPUT;CHAR(10)

The spooled file handle to the current file that is being processed by the writer. This handle is provided to the driver program on a writer call to the driver exit program (using the process file option).

Drawer for separator page
INPUT; BINARY(4)

The following values are allowed:

0 The separator drawer specified in the device description for the printer device name is used.
1 - 255 The drawer from which the separator page is printed.

Error code
I/O; CHAR(*)

The structure in which to return error information. For the format of the structure, see Error Code Parameter.


SEPP0100 Format

The following table shows the information returned for the SEPP0100 format. For more details about the fields in the following table see, Field Descriptions.

Offset Type Field
Dec Hex
0 0 BINARY(4) Bytes returned
4 4 BINARY(4) Bytes available
8 8 BINARY(4) Offset to separator page data
12 C BINARY(4) Size of separator page data
16 10 CHAR(*) Separator page data

Field Descriptions

Bytes available. The number of bytes of data available to be returned. All available data is returned if enough space is provided.

Bytes returned. The number of bytes of data returned.

Offset to separator page data. The byte offset to the separator page data (from the beginning of the format).

Separator page data. The separator page data, which includes printer commands and the data to be printed.

Size of separator page data. The size of the separator page data, in bytes.


Error Messages

Message ID Error Message Text
CPF2207 E Not authorized to use object &1 in library &3 type *&2.
CPF24B4 E Severe error while addressing parameter list.
CPF2702 E Device description &1 not found.
CPF3CF1 E Error code parameter not valid.
CPF3C19 E Error occurred with receiver variable specified.
CPF3C21 E Format name &1 is not valid.
CPF3C24 E Length of the receiver variable is not valid.
CPF3C40 E Spooled file &4 not found.
CPF3C90 E Literal value cannot be changed.
CPF33CC E No writer found for specified handle &1.
CPF33CD E No file found for specified handle &1.
CPF3309 E No files named &1 are active.
CPF334C E Value &1 not valid for print data stream type.
CPF334D E Value &1 not valid for type of separator.
CPF334E E Value &1 not valid for separator drawer.
CPF3344 E File &1 number &2 no longer in the system.
CPF9810 E Library &1 not found.
CPF9811 E Program &1 in library &2 not found.
CPF9872 E Program or service program &1 in library &2 ended. Reason code &3.


API introduced: V3R7