Use this record-level keyword on the subfile control record format to specify that the Enter key is to be used as a Page Up key. This allows the i5/OS™ operating system to page through a subfile of more than one page when the Enter key is pressed.
SFLENTER(CAnn | CFnn)
This optional keyword is valid only for the subfile control record format.
If a subfile is not currently displayed or you cannot page through the subfiles displayed (they have one page or less) after you press the Enter key, control is returned to your program. The parameter value with this keyword is required. Use it to specify a function key to replace the Enter key while this function is active. This keyword is normally used when the subfile is entirely entered by the workstation user or when the user changes some records in the subfile and adds others.
Option indicators are not valid for this keyword.
If more than one subfile using SFLENTER is displayed at the same time, the only CA or CF key in effect as an Enter key is the CA or CF key specified for SFLENTER on the most recently displayed subfile. The cursor position at the time the Enter key is pressed determines which subfile is affected.
The following example shows how to specify the SFLENTER keyword.
|...+....1....+....2....+....3....+....4....+....5....+....6....+....7....+....8 00010A R SFLR SFL 00020A* 00030A* (at least one displayable field) 00040A R SFLCTLR SFLCTL(SFLR) 00050A SFLPAG(17) 00060A SFLSIZ(51) 00070A SFLDSP SFLDSPCTL 00080A SFLENTER(CF01) A
The Enter key is used as a Page Up key. To enter data, the workstation user presses CF01.