Under certain circumstances a directly attached console will fail to connect.
This may be the result of the server's communications adapter being deactivated for some reason, such as an exception that took place. This most likely will appear during an IPL and may have an associated system reference code (SRC) on the control panel along with the attention light. You can reset the communications line by performing a function 65 followed by a function 66 on the control panel or remote control panel. To reset the asynchronous communications adapter, do the following:
To deactivate the asynchronous communications line on the server, do the following:
The system attempts to initialize the line. If it is successful, the Function/Data window displays D1008066. If it could not initialize the line, it displays D1008065.