Using the same configuration example above (LAN to direct) and
assuming all hardware and configurations have been done, you would disconnect
the existing console (LAN-connected); use the console service functions (65+21),
native macro, or SST from another workstation to set the console mode to a
2 for directly attached consoles, then connect the local console directly
attached. However, if you used the native macro or SST from another workstation,
you may also have to activate the asynchronous communications adapter. Using
the console service functions (65+21) or native macro OPSCONSOLE RESTART automatically
activates the adapter.
Note: There are several console service functions (65+21)
that might be needed to recover or debug an Operations Console problem depending
on the problem, connectivity used for the current console, the target console
type, and the current state of the system.
If you are unsure of any function or recovery action contact your service
provider for assistance.