ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzajr_5.4.0.1/rzajrtroublesrccoded.htm

159 lines
8.9 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="reference" />
<meta name="DC.Title" content="System reference code A6005008" />
<meta name="abstract" content="Use this table if you received reference codes A6005008. If an IPL did not find a console and if the console type is set to anything except a 1, the system will display code A6005008." />
<meta name="description" content="Use this table if you received reference codes A6005008. If an IPL did not find a console and if the console type is set to anything except a 1, the system will display code A6005008." />
<meta name="DC.Relation" scheme="URI" content="rzajrtroublesrc.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="troublesrccoded" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>System reference code A6005008</title>
</head>
<body id="troublesrccoded"><a name="troublesrccoded"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">System reference code A6005008</h1>
<div><p>Use this table if you received reference codes A6005008. If an
IPL did not find a console and if the console type is set to anything except
a 1, the system will display code A6005008.</p>
<div class="section"><ul><li>If you are attempting to use a twinaxial console the only data relevant
in this SRC is word 16. Use the table below to determine the twinaxial failure.
The first 4 characters of this word contains the last 4 characters of the
original failure type. For example, if word 16 contained 50010001, the twinaxial-related
SRC code would be A6005001 and the console type is set to use a twinaxial
console. Refer to that SRC code.</li>
<li>If you are attempting to use Operations Console select the appropriate
section in the table below as follows: <ul><li>Local console on a network uses words 13, 14, and 15.</li>
<li>Local console directly attached to the server uses words 17, 18, and 19.</li>
</ul>
</li>
</ul>
<div class="note"><span class="notetitle">Note:</span> If you just replaced the LAN adapter associated with Operations
Console (LAN), you need to wait at least 35 minutes for the server to find
and use the new LAN adapter card. In this case, once the server is satisfied
it will start using the new adapter, the console should start and the reference
code will go away. </div>
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><thead align="left"><tr><th colspan="4" align="center" valign="top" id="d0e33">LAN</th>
</tr>
<tr><th valign="top" id="d0e36">If Word 13 value is:</th>
<th valign="top" id="d0e38">Failure</th>
<th valign="top" id="d0e40">Word 14 means:</th>
<th valign="top" id="d0e42">Word 15 means:</th>
</tr>
</thead>
<tbody><tr><td align="center" valign="top" headers="d0e33 d0e36 ">1</td>
<td valign="top" headers="d0e33 d0e38 ">No supported HW detected or HW detected is not expected
(for example, you replaced the LAN IOA so the serial number is different)</td>
<td valign="top" headers="d0e33 d0e40 ">&nbsp;</td>
<td valign="top" headers="d0e33 d0e42 ">In some cases the serial number of the expected adapter
may be shown.</td>
</tr>
<tr><td align="center" valign="top" headers="d0e33 d0e36 ">2</td>
<td valign="top" headers="d0e33 d0e38 ">LAN IOA failed to report</td>
<td valign="top" headers="d0e33 d0e40 ">&nbsp;</td>
<td valign="top" headers="d0e33 d0e42 ">&nbsp;</td>
</tr>
<tr><td align="center" valign="top" headers="d0e33 d0e36 ">3</td>
<td valign="top" headers="d0e33 d0e38 ">Hardware error</td>
<td valign="top" headers="d0e33 d0e40 ">Common error codes: 53001A80,53002AC0 Network, cable
or the LAN adapter may not be operational. Error code: 00000000 . This error
code indicates the adapter reported but has not been initialized yet. This
is not considered an error, at this time. The adapter should be activated
shortly. For other error codes contact your service provider.</td>
<td valign="top" headers="d0e33 d0e42 ">Card position or serial number of adapter</td>
</tr>
<tr><td align="center" valign="top" headers="d0e33 d0e36 ">4</td>
<td valign="top" headers="d0e33 d0e38 ">BOOTP status: If attempts are zero, then BOOTP is ready,
when called. If attempts have a value, then the PC did not respond</td>
<td valign="top" headers="d0e33 d0e40 ">Attempts</td>
<td valign="top" headers="d0e33 d0e42 ">Card position or serial number of adapter</td>
</tr>
<tr><td align="center" valign="top" headers="d0e33 d0e36 ">5</td>
<td valign="top" headers="d0e33 d0e38 ">Server's LAN connection is active but the PC failed
to connect - Is the PC &amp; server on the same network? Using the same protocol?
Can the PC ping the server? (<kbd class="userinput">ping serverhostname</kbd>)</td>
<td valign="top" headers="d0e33 d0e40 ">IP address </td>
<td valign="top" headers="d0e33 d0e42 ">Card position or serial number of adapter</td>
</tr>
<tr><td colspan="2" valign="top" headers="d0e33 d0e36 d0e38 ">Word 16</td>
<td colspan="2" valign="top" headers="d0e33 d0e40 d0e42 ">The twinaxial-related SRC is represented
by the first 4 characters. The console type value is represented by the last
4 characters in the form xxxx xxxx. <ul><li>00 = Not defined by user (old default value), see note below.</li>
<li>01 = Twinaxial</li>
<li>02 = Operations Console (direct)</li>
<li>03 = Operations Console (LAN)</li>
</ul>
</td>
</tr>
</tbody>
</table>
</div>
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><thead align="left"><tr><th colspan="4" align="center" valign="top" id="d0e113">Cable</th>
</tr>
<tr><th valign="top" id="d0e116">If Word 17 value is:</th>
<th valign="top" id="d0e118">Failure</th>
<th valign="top" id="d0e120">Word 18 means:</th>
<th valign="top" id="d0e122">Word 19 means:</th>
</tr>
</thead>
<tbody><tr><td align="center" valign="top" headers="d0e113 d0e116 ">1</td>
<td valign="top" headers="d0e113 d0e118 ">Async card not detected</td>
<td valign="top" headers="d0e113 d0e120 ">&nbsp;</td>
<td valign="top" headers="d0e113 d0e122 ">&nbsp;</td>
</tr>
<tr><td align="center" valign="top" headers="d0e113 d0e116 ">2</td>
<td valign="top" headers="d0e113 d0e118 ">No cables detected</td>
<td valign="top" headers="d0e113 d0e120 ">Card position</td>
<td valign="top" headers="d0e113 d0e122 ">Card type</td>
</tr>
<tr><td align="center" valign="top" headers="d0e113 d0e116 ">3</td>
<td valign="top" headers="d0e113 d0e118 ">Wrong cable detected</td>
<td valign="top" headers="d0e113 d0e120 ">Card position</td>
<td valign="top" headers="d0e113 d0e122 ">Cable ID</td>
</tr>
<tr><td align="center" valign="top" headers="d0e113 d0e116 ">4</td>
<td valign="top" headers="d0e113 d0e118 ">Port in use</td>
<td valign="top" headers="d0e113 d0e120 ">Card position</td>
<td valign="top" headers="d0e113 d0e122 ">Card type</td>
</tr>
<tr><td align="center" valign="top" headers="d0e113 d0e116 ">FA</td>
<td valign="top" headers="d0e113 d0e118 ">Not configured for direct cable</td>
<td valign="top" headers="d0e113 d0e120 ">&nbsp;</td>
<td valign="top" headers="d0e113 d0e122 ">&nbsp;</td>
</tr>
</tbody>
</table>
</div>
<div class="note"><span class="notetitle">Note:</span> It is expected that a D-mode IPL with a new load source DASD
will show the console mode value of 00. Examples of when this can occur might
be that the copy of data from a failing DASD did not copy all data or you
are installing a new logical partition. Also, there are times when the DASD
is late reporting an the console mode value was not retrieved in time. In
these cases you can use the console service function to set a console mode
value or attempt to contact the console again. </div>
</div>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzajrtroublesrc.htm" title="Solutions to system reference code (SRC) data received on your server.">Troubleshoot system reference code (SRC) data</a></div>