ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzajr_5.4.0.1/rzajrmanualipl.htm

110 lines
7.3 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="Start the system using a manual IPL" />
<meta name="abstract" content="Use this section to start your server by performing a manual initial program load (IPL)." />
<meta name="description" content="Use this section to start your server by performing a manual initial program load (IPL)." />
<meta name="DC.Relation" scheme="URI" content="rzajrcommonservertasks.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="manualipl" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Start the system using a manual IPL</title>
</head>
<body id="manualipl"><a name="manualipl"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Start the system using a manual IPL</h1>
<div><p>Use this section to start your server by performing a manual initial
program load (IPL). </p>
<div class="section"> <p>These instructions assume the server is powered off. If the server
is powered on, use one of the various methods available to start the manual
IPL. </p>
<p>To perform a manual IPL, follow these steps:</p>
</div>
<ol><li class="stepexpand"><span>Look at the Function/Data display on the iSeries control panel.</span> Systems with a keystick should show the mode as <samp class="codeph">Manual</samp> and <samp class="codeph">01
B</samp> in the Function/Data display.<p>Systems without a keystick should
show as <samp class="codeph">01 BM</samp> in the Function/Data display.</p>
</li>
<li class="stepexpand"><span>If the system is in <samp class="codeph">Manual</samp> mode and will IPL on
the B side, then go to step 8. If the system is not in Manual mode or not
set to IPL on the B side, then continue with step 3.</span></li>
<li class="stepexpand"><span>If the Function/Data display is lit, then, continue with step 4.</span> If the Function/Data display is not lit, do the following before calling
your hardware service representative: <ul><li>Confirm that the electrical outlet is functioning by plugging in a suitable
device for the voltage.</li>
<li>Ensure that the power cord is securely plugged into the system unit and
electrical outlet.</li>
</ul>
</li>
<li class="stepexpand"><span>Press <span class="uicontrol">Up</span> or <span class="uicontrol">Down</span> until <samp class="codeph">02</samp> appears
in the Function/Data display.</span> <div class="note"><span class="notetitle">Note:</span> If your system uses a keystick,
insert it now and select <span class="uicontrol">Manual</span> by using the <span class="uicontrol">Mode</span> button.</div>
</li>
<li class="stepexpand"><span>Press <span class="uicontrol">Enter</span> on the iSeries control panel.</span></li>
<li class="stepexpand"><span>Press Up or Down until <samp class="codeph">B M</samp> appears in the Function/Data
display. If your system uses a keystick, select <span class="uicontrol">B</span>.
The Function/Data display should show <samp class="codeph">02 B</samp>.</span></li>
<li class="stepexpand"><span>Press <span class="uicontrol">Enter</span> on the iSeries control panel.</span></li>
<li class="stepexpand" id="manualipl__sgofas400su"><a name="manualipl__sgofas400su"><!-- --></a><span>Press <span class="uicontrol">Power</span> on the iSeries
control panel.</span> The system takes approximately 10 to 45 minutes
to power on and progress through an IPL far enough to continue with these
instructions. You should see that the data changes in the Function/Data display.
The last step of the IPL may take up to 30 minutes to complete or the <span class="uicontrol">Attention</span> light
may turn on.</li>
<li class="stepexpand"><span>Reference code x6004031 or x6004508 (where x can be any letter)
will appear in the Function/Data display and remain for up to 30 minutes.</span></li>
<li class="stepexpand"><span>When the system has completed the initial phase of the manual IPL
it should show <samp class="codeph">01 B </samp> and you have a console.</span> <div class="note"><span class="notetitle">Note:</span> There
are other SRC codes that may be displayed without the attention light being
on. One example is x6xx450x (where the x can be any letter or number). These
SRC codes usually indicate the server detected an unexpected condition and
the console may have data indicating this condition. This condition and the
resulting console data precede the IPL or Install the System screen.</div>
<p>If
the <span class="uicontrol">Attention</span> light is lit, then go to step 11.</p>
<p>If
the <span class="uicontrol">Attention</span> light is not lit and you
do not have a console, then, consider the following: </p>
<ul><li>Your system may not have progressed through an IPL far enough to continue
with these instructions. Wait at least 30 minutes before going any further.</li>
<li>If, after 30 minutes, you do not see any system activity and the Attention
light did not light: See the information about handling and reporting system
problems in <a href="../rzahg/rzahgictroub2.htm">Troubleshooting
and service</a>.</li>
<li>When the problem has been resolved, start at the beginning of this section
again.</li>
</ul>
</li>
<li class="stepexpand"><span>If you see System Reference Code (SRC) x6xx500x (where the x can
be any letter or number) in the Function/Data display, then, go to <a href="rzajrtroublesrc.htm#troublesrc">Troubleshoot
system reference code (SRC) data</a>.</span> If you do not see System
Reference Code (SRC) x6xx500x (where the x can be any letter or number) in
the Function/Data display, then, see the information about handling and reporting
system problems in <a href="../rzahg/rzahgictroub2.htm">Troubleshooting
and service</a>.<div class="note"><span class="notetitle">Note:</span> If you are working with a console related problem
the most common SRC code reported would be A6005008. If you see any reference
code of A600500x (where x can be any number) then you can proceed with any
console service functions (65+21) to debug or make changes. </div>
</li>
</ol>
</div>