<?xml version="1.0" encoding="UTF-8"?>
|
||
|
<!DOCTYPE html
|
||
|
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
||
|
<html lang="en-us" xml:lang="en-us">
|
||
|
<head>
|
||
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
||
|
<meta name="security" content="public" />
|
||
|
<meta name="Robots" content="index,follow" />
|
||
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
||
|
<meta name="DC.Type" content="task" />
|
||
|
<meta name="DC.Title" content="Preparing your console for software installation" />
|
||
|
<meta name="abstract" content="Before you install a new software release, consider this information on consoles." />
|
||
|
<meta name="description" content="Before you install a new software release, consider this information on consoles." />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzahcrequiredtasks.htm" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2004, 2006" />
|
||
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2004, 2006" />
|
||
|
<meta name="DC.Format" content="XHTML" />
|
||
|
<meta name="DC.Identifier" content="rzahcswsdspport" />
|
||
|
<meta name="DC.Language" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
||
|
<title>Preparing your console for software installation</title>
|
||
|
</head>
|
||
|
<body id="rzahcswsdspport"><a name="rzahcswsdspport"><!-- --></a>
|
||
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
||
|
<h1 class="topictitle1">Preparing your console for software installation</h1>
|
||
|
<div><p>Before you install a new software release, consider this information
|
||
|
on consoles.</p>
|
||
|
<div class="section"> <p>Although you can use twinaxial console on most servers, IBM recommends
|
||
|
for V5R4 that you use either Operations Console or Hardware Management Console.
|
||
|
For requirements on twinaxial console, Operations Console, and PCs, refer
|
||
|
to the category, <a href="../rzahg/rzahgicinterface.htm">Connecting
|
||
|
to iSeries</a> .
|
||
|
If you are moving from twinaxial console to Operations Console, use the <cite>iSeries
|
||
|
Setup and Operations CD-ROM, <span>SK3T-4098-02</span></cite>, to install Operations
|
||
|
Console before you install the new release. </p>
|
||
|
<p>If you are using twinaxial
|
||
|
console, the software installation process expects the system console device
|
||
|
to be attached at port 0 and address 0 of the first workstation controller.
|
||
|
In most cases, your hardware should be defined in this way. You should verify
|
||
|
that the console is attached at port 0 address 0.</p>
|
||
|
<p>If you are
|
||
|
planning on migrating your Operations Console, do so either before or after
|
||
|
you upgrade. If you are planning on migrating your Hardware Management Console
|
||
|
(HMC), do so only after you have completely installed your system. For more
|
||
|
information about using the HMC as your <span class="keyword">i5/OS™</span> console,
|
||
|
see <a href="../icbase/iphb7/i5osconsoles.htm" target="_blank">Managing <span class="keyword">i5/OS</span> consoles</a> .</p>
|
||
|
<p>For
|
||
|
all servers, verify that the console mode value is set correctly for your
|
||
|
console. In addition, you can specify that an i5/OS LAN console or Hardware Management
|
||
|
Console be taken over by another console in the event your console is disconnected.
|
||
|
To verify the console mode value, follow these steps:</p>
|
||
|
</div>
|
||
|
<ol><li class="stepexpand"><span>Access Dedicated Service Tools (DST).</span></li>
|
||
|
<li class="stepexpand"><span>Select <strong>Work with DST environment</strong>.</span></li>
|
||
|
<li class="stepexpand"><span>Select <strong>System Devices</strong>.</span></li>
|
||
|
<li class="stepexpand"><span>Select <strong>Console mode</strong>. </span> <p>The value of the current
|
||
|
console mode is present in the input field. Verify that this is the correct
|
||
|
setting. A value of zero means that the console mode has not been set and
|
||
|
can interfere with the automatic installation process. The console mode value
|
||
|
must be one of the following values.</p>
|
||
|
|
||
|
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><tbody><tr><td valign="top" width="16.751269035532996%">1</td>
|
||
|
<td valign="top" width="83.24873096446701%">Twinaxial console</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" width="16.751269035532996%">2</td>
|
||
|
<td valign="top" width="83.24873096446701%">Operations Console (directly attached)</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" width="16.751269035532996%">3</td>
|
||
|
<td valign="top" width="83.24873096446701%">Operations Console (LAN attached)</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" width="16.751269035532996%">4</td>
|
||
|
<td valign="top" width="83.24873096446701%">Hardware Management Console (HMC)</td>
|
||
|
</tr>
|
||
|
</tbody>
|
||
|
</table>
|
||
|
</div>
|
||
|
<p>During an installation or upgrade to V5R4, the console
|
||
|
type specified by this value is used. </p>
|
||
|
<p>The console mode display also
|
||
|
includes the option to allow your 5250 console (does not include twinaxial
|
||
|
console) to be taken over by another console. When this option is turned on,
|
||
|
the system does not stop with a failure but continues to run uninterrupted.
|
||
|
For more information, see the topic <a href="../icbase/iphbx/consoletakeoverandrecover.htm" target="_blank">Console takeover and recovery</a> .</p>
|
||
|
</li>
|
||
|
</ol>
|
||
|
<div class="section"> <div class="p">If you use Operations Console, do the following before you install <span>V5R4</span> on your server: <ul><li>Review the <a href="../rzajr/rzajropconoverview.htm">Operations
|
||
|
Console</a> topic. To review the most recent information on the Operations
|
||
|
Console client, go to the <a href="http://www.ibm.com/eserver/iseries/access/console/" target="_blank">Operations Console Web site</a> <img src="www.gif" alt="Link outside information center" /> </li>
|
||
|
<li>IBM recommends that you update IBM<sup>®</sup> eServer™ iSeries™ Access for Windows<sup>®</sup> to <span>V5R4</span> before you upgrade the <span class="keyword">i5/OS</span> operating
|
||
|
system. For more information, see <a href="../rzaij/rzaijrzaijinstall.htm">iSeries
|
||
|
Access for Windows: Installation and setup</a> .</li>
|
||
|
<li>If you use the Operations Console configuration, <samp class="codeph">Local
|
||
|
console directly attached to the server</samp>, and the adapter used for
|
||
|
the cable connection is 2771, the adapter must be in a specific position.
|
||
|
For independent or primary partitions only, the position is based on the server
|
||
|
model shown in the following table. <div class="note"><span class="notetitle">Note:</span> This applies only to <span class="keyword">iSeries</span> 270 and 8xx models. This does
|
||
|
not apply to <span>IBM <span class="keyword">System i5</span>,
|
||
|
System p5, and IBM eServer i5
|
||
|
and p5 systems</span>.</div>
|
||
|
|
||
|
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" class="singleborder" frame="border" border="1" rules="all"><caption>Table 1. Card position</caption><thead align="left"><tr class="tablemainheaderbar"><th valign="bottom" id="d0e185">Server model</th>
|
||
|
<th valign="bottom" id="d0e187">Operations Console asynchronous card position for the
|
||
|
cable</th>
|
||
|
</tr>
|
||
|
</thead>
|
||
|
<tbody><tr><td valign="top" headers="d0e185 ">270</td>
|
||
|
<td valign="top" headers="d0e187 ">C07</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e185 ">800 or 810</td>
|
||
|
<td valign="top" headers="d0e187 ">C07</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e185 ">820</td>
|
||
|
<td valign="top" headers="d0e187 ">C06</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e185 ">825</td>
|
||
|
<td valign="top" headers="d0e187 ">C06</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e185 ">830 or SB2</td>
|
||
|
<td valign="top" headers="d0e187 ">C02</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e185 ">840 or SB3</td>
|
||
|
<td valign="top" headers="d0e187 ">C02</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e185 ">870 or 890</td>
|
||
|
<td valign="top" headers="d0e187 ">C02</td>
|
||
|
</tr>
|
||
|
</tbody>
|
||
|
</table>
|
||
|
</div>
|
||
|
</li>
|
||
|
<li>When you receive the <span class="keyword">i5/OS</span> release
|
||
|
upgrade, the shipped service tools user IDs (except 11111111) are expired.
|
||
|
For all upgrades and installations, you need to establish a connection between <span>the
|
||
|
server and Operations Console PC by using</span> 11111111 (eight 1's) for both
|
||
|
the service tools user ID and the default password. This ensures a successful
|
||
|
authentication of the subsequent connection of the client to the server. This
|
||
|
is especially important for automatic installations.</li>
|
||
|
</ul>
|
||
|
</div>
|
||
|
<p>Failure to comply with the above actions can prevent the console
|
||
|
from working correctly during the upgrade or installation. </p>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div>
|
||
|
<div class="familylinks">
|
||
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzahcrequiredtasks.htm" title="Complete these initial installation tasks, which include saving the server. Several of these initial tasks are required for a successful software upgrade.">Performing initial upgrade or replacement tasks</a></div>
|
||
|
</div>
|
||
|
</div>
|
||
|
</body>
|
||
|
</html>
|