ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzau3_5.4.0.1/rzau3spdopticonnect.htm

74 lines
4.7 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-10-17" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>SPD OptiConnect</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="spdopticonnect"></a>
<h3 id="spdopticonnect">SPD OptiConnect</h3>
<p>SPD OptiConnect is the term used to refer to OptiConnect licensed software
providing high speed server-to-server connectivity between servers which are
connected to each other through SPD bus technology. SPD OptiConnect requires
a SPD bus which is available on earlier iSeries&trade; server models and supported through
the 5077 SPD migration unit supported on some iSeries 8xx models. iSeries server models
with HSL-2 ports do not support SPD OptiConnect.</p>
<p> The servers in a SPD OptiConnect network share a common external optical
system bus that is located in a dedicated expansion unit or frame (also called
a SPD OptiConnect hub unit). The server that provides this system bus is called
the <span class="bold">hub</span> server. The hardware used to create a hub server
for a SPD OptiConnect network consists of a dedicated system I/O expansion
unit or frame. Each server that plugs into this bus with an OptiConnect Receiver
card is called a <span class="bold">satellite</span> server. Each satellite server
dedicates one of its external system buses to connect to the receiver card
in the hub server's expansion unit or frame.</p>
<p>Redundancy is supported on SPD OptiConnect networks through SPD bus redundancy.
Redundancy requires a second SPD OptiConnect Hub, an extra set of OptiConnect
Receiver cards, and an extra I/O expansion unit or frame, along with another
set of cables.</p>
<a name="wq4"></a>
<div class="notetitle" id="wq4">Note:</div>
<div class="notebody">Servers attached to the hub server do <span class="bold">not</span> use the hub server's CPU resources.</div>
<a name="spdopti"></a>
<div class="fignone" id="spdopti"><span class="figcap">Figure 4. SPD OptiConnect</span>
<div class="mmobj">
<img src="rzaeb506.gif" alt="SPD OptiConnect" /></div></div>
<p><a href="rzau3spdopticonnect.htm#spdopti">Figure 4</a> shows a dual bus configuration, providing full redundancy
in the SPD OptiConnect system area network. If one of the hub servers fail,
the SPD OptiConnect network remains up, and all communications activity is
run through the other hub. When both hubs are operating, the communications
traffic is shared between both. This increases the bandwidth with two paths
available for use.</p>
<p>An SPD OptiConnect network can consist of up to 14 servers (one hub and
13 satellites) with full server-to-server connectivity. A satellite server
can communicate with both hub servers and all satellite servers on the same
shared bus. Interoperability between operating system versions is maintained
so that servers at different release levels can be connected in the same SPD
OptiConnect network. With additional hubs, up to 32 servers can be supported.</p>
<p>iSeries models 840, 830, and 270 can participate in an SPD OptiConnect
environment by using a migration unit.</p>
<p>For more information about SPD OptiConnect (including information about
supported models) see the <a href="http://www.ibm.com/servers/eserver/iseries/ha/" target="_blank">High Availability and Clusters Web Site</a> (www.ibm.com/servers/eserver/iseries/ha).
<img src="www.gif" alt="Link outside Information Center" /></p>
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
</body>
</html>