56 lines
3.2 KiB
HTML
56 lines
3.2 KiB
HTML
|
<?xml version="1.0" encoding="utf-8"?>
|
||
|
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
|
||
|
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
||
|
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
|
||
|
<head>
|
||
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
||
|
<meta name="dc.language" scheme="rfc1766" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<meta name="dc.date" scheme="iso8601" content="2005-10-17" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2006" />
|
||
|
<meta name="security" content="public" />
|
||
|
<meta name="Robots" content="index,follow"/>
|
||
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
||
|
<title>Re-establish system connections when OptiConnect is installed</title>
|
||
|
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="ic.css" />
|
||
|
</head>
|
||
|
<body>
|
||
|
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
|
||
|
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
|
||
|
|
||
|
|
||
|
<a name="prec"></a>
|
||
|
<h2 id="prec">Re-establish system connections when OptiConnect is installed</h2>
|
||
|
<p>You should always use the Power Down System (PWRDWNSYS) command when you
|
||
|
power down a system that is connected with OptiConnect. If you do not use
|
||
|
the PWRDWNSYS command, you could experience difficulties with system-to-system
|
||
|
connections.</p>
|
||
|
<p>Certain conditions can cause system-to-system connections to become inoperative.
|
||
|
Performing an IPL on one of the systems is the only way to reestablish these
|
||
|
connections.</p>
|
||
|
<p>You can avoid these conditions by using the PWRDWNSYS command. However,
|
||
|
some conditions, such as abnormal operations, or loss of power on one system
|
||
|
in the OptiConnect network, may make it necessary to perform an IPL. Additional
|
||
|
examples are:</p>
|
||
|
<ul>
|
||
|
<li>Emergency power off (EPO)</li>
|
||
|
<li>Utility or uninterruptible power supply failure</li>
|
||
|
<li>Hardware failures</li>
|
||
|
<li>Interrupted IPLs or failure of an IPL</li></ul>
|
||
|
<p>If you suspect one of these conditions has occurred, check the status of
|
||
|
the bus expansion adapter by using the Work with Hardware Resources (WRKHDWRSC)
|
||
|
command. For more information on using this command, see <a href="rzau3whrsc.htm#whrsc">Work with hardware resources (WRKHDWRSC)</a>.
|
||
|
Report hardware failures by contacting your IBM® Service Representative.</p>
|
||
|
<a name="wq60"></a>
|
||
|
<div class="notetitle" id="wq60">Note:</div>
|
||
|
<div class="notebody">Problems can occur if the odd bus on the Optical Link card
|
||
|
was used to connect to a non-OptiConnect expansion unit. See<a href="rzau3spdopticonnect.htm#spdopticonnect">SPD OptiConnect</a> for
|
||
|
more information on OptiConnect configurations.</div>
|
||
|
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
|
||
|
</body>
|
||
|
</html>
|