80 lines
5.0 KiB
HTML
80 lines
5.0 KiB
HTML
|
<?xml version="1.0" encoding="utf-8"?>
|
||
|
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
|
||
|
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
||
|
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
|
||
|
<head>
|
||
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
||
|
<meta name="dc.language" scheme="rfc1766" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<meta name="dc.date" scheme="iso8601" content="2005-10-17" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2006" />
|
||
|
<meta name="security" content="public" />
|
||
|
<meta name="Robots" content="index,follow"/>
|
||
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
||
|
<title>HSL OptiConnect</title>
|
||
|
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="ic.css" />
|
||
|
</head>
|
||
|
<body>
|
||
|
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
|
||
|
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
|
||
|
|
||
|
|
||
|
<a name="hsl"></a>
|
||
|
<h3 id="hsl">HSL OptiConnect</h3>
|
||
|
<p>HSL OptiConnect is the term used to refer to the OptiConnect licensed software
|
||
|
providing high speed server-to-server connectivity between two or three servers
|
||
|
which are connected to each other through an HSL OptiConnect loop. It also
|
||
|
refers to the HSL Loop technology used to connect two or three physical servers
|
||
|
together on a single loop. Each server may have one or more LPAR partitions
|
||
|
participating in the OptiConnect network.</p>
|
||
|
<p>While each HSL OptiConnect loop is limited to three servers, OptiConnect
|
||
|
software will support multiple HSL OptiConnect loops between servers, providing
|
||
|
loop redundancy in addition to the hardware redundancy provided within each
|
||
|
HSL loop. It should be noted that any LPAR partition on the server may be
|
||
|
allowed to participate in the HSL OptiConnect loop functions without additional
|
||
|
cost.</p>
|
||
|
<p>To activate Virtual OptiConnect communications between LPAR partitions,
|
||
|
the OptiConnect licensed software must be installed on all of the partitions
|
||
|
where you want to use Virtual OptiConnect and the OptiConnect subsystem must
|
||
|
be started on each of these partitions.</p>
|
||
|
<p>On 5xx models, from the Hardware Management Console (HMC), select Server
|
||
|
Management and then select the local partition profile properties. Under the
|
||
|
OptiConnect tab select Use High Speed Link (HSL) OptiConnect. In order for
|
||
|
the change to take effect, you must activate the partition from the HMC.</p>
|
||
|
<p>On 8xx models, use the dedicated service tools (DST) or system service
|
||
|
tools (SST) to configure each LPAR partition into the HSL OptiConnect loop
|
||
|
environment. From the primary partition set the communication option "Connect
|
||
|
to HSL OptiConnect" to "yes" for each partition (in addition to the primary)
|
||
|
that uses the OptiConnect function.</p>
|
||
|
<p>The following figure shows an example of two servers that are connected
|
||
|
through an HSL OptiConnect loop. When OptiConnect software is installed and
|
||
|
running, a high-speed server-to-server connection is maintained. Two servers
|
||
|
can have more than one HSL loop that connects them together, providing the
|
||
|
server model supports more than one HSL OptiConnect loop.</p>
|
||
|
<a name="hslopti"></a>
|
||
|
<div class="fignone" id="hslopti"><span class="figcap">Figure 1. HSL OptiConnect</span>
|
||
|
<div class="mmobj">
|
||
|
<img src="rzaeb504.gif" alt="HSL OptiConnect Example" /></div></div>
|
||
|
<p>There are two HSL cabling types: HSL and HSL-2. Servers and expansion units
|
||
|
may have HSL or HSL-2 cable ports, depending on the model. Both types are
|
||
|
supported on an HSL OptiConnect loop by using an HSL to HSL-2 cable.</p>
|
||
|
<p>HSL OptiConnect loops also support the use of HSL fiber-optic cables. This
|
||
|
technology is offered on some models. The entire HSL OptiConnect loop must
|
||
|
use the fiber-optic cables.</p>
|
||
|
<p>The following figure shows an example of a three-server HSL OptiConnect
|
||
|
loop. All servers in a three-server HSL OptiConnect loop must be at the minimum
|
||
|
operating system release level of the most current hardware.</p>
|
||
|
<a name="wq3"></a>
|
||
|
<div class="fignone" id="wq3"><span class="figcap">Figure 2. Three server HSL OptiConnect Loop</span>
|
||
|
<div class="mmobj">
|
||
|
<img src="rzaeb502.gif" alt="Three server HSL OptiConnect Loop" /></div></div>
|
||
|
<p>Additional information about HSL cabling can also be found on the <a href="http://www.ibm.com/servers/eserver/iseries/ha/" target="_blank">High Availability and Clusters Web Site</a> (www.ibm.com/servers/eserver/iseries/ha).
|
||
|
<img src="www.gif" alt="Link outside Information Center" /></p>
|
||
|
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
|
||
|
</body>
|
||
|
</html>
|