<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Match iSeries system parameters for 3684 retail controllers</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="rzajt-cfg400to3684-rf"></a>
<h4 id="rzajt-cfg400to3684-rf">Match iSeries system parameters for 3684 retail controllers</h4>
<p>You must coordinate parameters with the iSeries&trade; system and the 3684 retail controller.
The following table lists those parameters.</p>
<p>iSeries parameters are listed in alphabetical order; the commands on
which the parameters are specified are included in the rightmost column of
the table.</p>
<p>To configure the iSeries server to a 3684 controller, use the following
table.</p>
<p></p>
<a name="wq140"></a>
<table id="wq140" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
<thead valign="bottom">
<tr>
<th id="wq141" width="14%" align="center" valign="bottom">iSeries Prompt</th>
<th id="wq142" width="14%" align="center" valign="bottom">iSeries Parameter</th>
<th id="wq143" width="14%" align="center" valign="bottom">3684 Definition Statement</th>
<th id="wq144" width="57%" align="center" valign="bottom">3684 Parameter</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left" valign="top" headers="wq141">Connection type</td>
<td align="left" valign="top" headers="wq142">CNN</td>
<td align="left" valign="top" headers="wq143">QFSFGLNK</td>
<td align="left" valign="top" headers="wq144">LINECON
<p>Value specified for the iSeries CNN parameter
on the CRTLINSDLC command must match the values specified for bits 2 and 3
of the 3684 LINECON parameter.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq141">Duplex</td>
<td align="left" valign="top" headers="wq142">DUPLEX</td>
<td align="left" valign="top" headers="wq143">QFSFGLNK</td>
<td align="left" valign="top" headers="wq144">LINECON
<p>Value specified for the iSeries DUPLEX parameter
on the CRTLINSDLC command must match the value specified for bit 6 of the
3684 LINECON parameter.</p></td>
</tr>
<tr>
<td rowspan="2" align="left" valign="top" headers="wq141">Exchange identifier</td>
<td rowspan="2" align="left" valign="top" headers="wq142">EXCHID</td>
<td rowspan="2" align="left" valign="top" headers="wq143">QVSFGLNK</td>
<td align="left" valign="top" headers="wq144">SENDID
<p>3684 SENDID parameter must match
the last 5 digits of the EXCHID parameter specified on the iSeries CRTCTLRTL
command.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq144">RECVID
<p>3684 RECVID parameter must match
the last 5 digits of the EXCHID parameter specified on the iSeries CRTLINSDLC
command. (This parameter is used only for switched line communications.)</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq141">Modem data rate</td>
<td align="left" valign="top" headers="wq142">MODEMRATE</td>
<td align="left" valign="top" headers="wq143">QFSFGLNK</td>
<td align="left" valign="top" headers="wq144">LINECON
<p>Value specified for the iSeries MODEMRATE
parameter on the CRTLINSDLC command must match the value specified for bit
5 of the 3684 LINECON parameter.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq141">NRZI data encoding</td>
<td align="left" valign="top" headers="wq142">NRZI</td>
<td align="left" valign="top" headers="wq143">QFSFGLNK</td>
<td align="left" valign="top" headers="wq144">LINECON
<p>Value specified for the iSeries NRZI parameter
on the CRTLINSDLC command must match the value specified for bit 1 of the
3684 LINECON parameter.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq141">Switched network backup</td>
<td align="left" valign="top" headers="wq142">SNBU</td>
<td align="left" valign="top" headers="wq143">QFSFGLNK</td>
<td align="left" valign="top" headers="wq144">LINECON
<p>Value specified for the iSeries SNBU parameter
on the CRTLINSDLC command must match the value specified for bit 4 of the
3684 LINECON parameter.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq141">SSCP identifier</td>
<td align="left" valign="top" headers="wq142">SSCPID</td>
<td align="left" valign="top" headers="wq143">QVSFGLNK</td>
<td align="left" valign="top" headers="wq144">SSCPID
<p>3684 SSCPID parameter must match
the SSCPID parameter specified on the iSeries CRTCTLRTL command.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq141">Station address</td>
<td align="left" valign="top" headers="wq142">STNADR</td>
<td align="left" valign="top" headers="wq143">QVSFGLNK</td>
<td align="left" valign="top" headers="wq144">POLCHAR
<p>3684 POLCHAR parameter must match
the 2-digit hexadecimal address specified for the STNADR parameter on the iSeries CRTCTLRTL command. Allowed values are in the range 01 through FE.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq141">Switched connection</td>
<td align="left" valign="top" headers="wq142">SWITCHED</td>
<td align="left" valign="top" headers="wq143">QFSFGLNK</td>
<td align="left" valign="top" headers="wq144">LINECON
<p>Value specified for the iSeries SWITCHED
parameter on the CRTCTLRTL command must match the values specified for bits
2 and 3 of the 3684 LINECON parameter.</p></td>
</tr>
<tr>
<td colspan="4" align="left" valign="top" headers="wq141 wq142 wq143 wq144">
<a name="wq145"></a>
<div class="notetitle" id="wq145">Note:</div>
<div class="notebody">For the iSeries server, the 3684 QVSFGLNK, QVSFCOMM, and QVSFSESN definitions
must each specify DATALNK=SDLC.
<p>Values specified for the iSeries parameters
on the CRTCTLRTL and CRTLINSDLC commands must match the values specified on
the 3684 LINECON parameter.</p></div></td>
</tr>
</tbody>
</table>
<p>For information about the LINECON parameter, see <a href="rzajtrzajtcfg400to3684sdlcrf.htm#rzajt-cfg400to3684sdlc-rf">Specify the LINECON parameter for 3684 retail controllers</a>.</p>
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
</body>