ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzati_5.4.0.1/rzatidst2hours.htm

78 lines
4.8 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="System time adjusted 2 hours for DST rather than 1 hour" />
<meta name="DC.Relation" scheme="URI" content="rzatitroubleshooting.htm" />
<meta name="DC.Relation" scheme="URI" content="../rzakz/rzakzqtimzon.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzatidst2hours" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>System time adjusted 2 hours for DST rather than 1 hour</title>
</head>
<body id="rzatidst2hours"><a name="rzatidst2hours"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">System time adjusted 2 hours for DST rather than 1 hour</h1>
<div><div class="section"><p><strong>Problem</strong></p>
<p>If the current time zone (QTIMZON) system
value observes daylight saving time (DST), the system automatically updates
the system time for DST. If the system is also set to use other automatic
adjustments for DST, more than 1 time adjustment might occur.</p>
<p>For example,
if your time zone (QTIMZON) system value is set to Eastern Standard Time (EST),
your system time will adjust 1 hour forward the first Sunday in April to observe
Eastern Daylight Time (EDT). In addition, you can have the i5/OS™ job scheduler
of iSeries™ Navigator
set to automatically adjust the system time 1 hour forward on the first Sunday
of April. With this environment, the system time adjusts a total of 2 hours
forward on the first Sunday of April rather than 1 hour.</p>
<p><strong>Recovery
steps</strong></p>
<p>If your system time was adjusted by other automatic methods
(such as the i5/OS job
scheduler), you need to disable the automatic adjustments and adjust the system
time 1 hour to compensate for the additional hour. To do this, complete the
following steps:</p>
</div>
<ol><li class="stepexpand"><span>Disable any other automatic time adjustments, if the time zone
that you are using observes DST.</span> <div class="note"><span class="notetitle">Note:</span> The steps to disable automatic
adjustments are unique to the application in use.</div>
</li>
<li class="stepexpand"><span>Adjust the system time by 1 hour by completing the following steps:</span><ol type="a"><li><span>In iSeries Navigator,
expand <span class="menucascade"><span class="uicontrol">My Connections</span> &gt; <span class="uicontrol">server-name</span> &gt; <span class="uicontrol">Configuration and Service</span> &gt; <span class="uicontrol">Time Management</span> &gt; <span class="uicontrol">Time Adjustment</span></span>.</span></li>
<li><span>Click <span class="uicontrol">Start New Time Adjustment</span>. If a
time adjustment is in progress, the current time adjustment will be stopped.
Before proceeding, ensure that you should stop the current adjustment.</span></li>
<li><span>Specify one hour positive or negative, depending on whether
you are starting or ending DST.</span></li>
<li><span>Click <span class="uicontrol">OK</span> to start the time adjustment.</span></li>
<li><span>If a time adjustment is already in progress, click <span class="uicontrol">OK</span> to
stop the current adjustment and to begin the new adjustment.</span></li>
</ol>
</li>
</ol>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzatitroubleshooting.htm" title="View this topic to troubleshoot problems your system might encounter. This topic describes a variety of problems and specifies recovery steps.">Troubleshooting</a></div>
</div>
<div class="relref"><strong>Related reference</strong><br />
<div><a href="../rzakz/rzakzqtimzon.htm">Time zone (QTIMZON) system value</a></div>
</div>
</div>
</body>
</html>