<meta name="DC.Type" content="task" />
|
||
|
<meta name="DC.Title" content="Remove failed or nonreporting resources" />
|
||
|
<meta name="abstract" content="Any hardware resources that were intended to be unassigned should be assigned to a partition in this step. These resources can then be unassigned as required after the expansion unit conversion." />
|
||
|
<meta name="description" content="Any hardware resources that were intended to be unassigned should be assigned to a partition in this step. These resources can then be unassigned as required after the expansion unit conversion." />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzamdexpanupgradelpardoc.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzamdexpanupgradelpardoc.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="../rzamh/rzamhwhatuserids.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzamdhwupgradesiteprep.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzamdhwupgradepreplpar.htm" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
|
||
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1998, 2006" />
|
||
|
<meta name="DC.Format" content="XHTML" />
|
||
|
<meta name="DC.Identifier" content="rzamdrmvresources" />
|
||
|
<meta name="DC.Language" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
||
|
<title>Remove failed or nonreporting resources</title>
|
||
|
</head>
|
||
|
<body id="rzamdrmvresources"><a name="rzamdrmvresources"><!-- --></a>
|
||
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
||
|
<h1 class="topictitle1">Remove failed or nonreporting resources</h1>
|
||
|
<div><p>Any hardware resources that were intended to be unassigned should be assigned to a partition in this step. These resources can then be unassigned as required after the expansion unit conversion. </p>
|
||
|
<div class="section"><p>To assign unassigned I/O resources, complete the following steps on the <strong>primary partition</strong>:</p>
|
||
|
<div class="attention"><span class="attentiontitle">Attention:</span> Any hardware problems must be resolved before continuing. I/O resources
|
||
|
that are nonreporting because they are switched between partitions and currently are not owned by the partition you are working in should not be removed by you at this time. Careful planning is required
|
||
|
when switched I/O is involved.</div>
|
||
|
</div>
|
||
|
<ol><li class="stepexpand"><span>Enter STRSST on a command line to start system service tools (SST) on the partition. Sign on to SST.</span> <div class="note"><span class="notetitle">Note:</span> To use system service tools, you need a valid service tools user ID.</div>
|
||
|
</li>
|
||
|
<li class="stepexpand"><span>Select option 1 (Start a Service Tool).</span></li>
|
||
|
<li class="stepexpand"><span>Select option 7 (Hardware Service Manager (HSM)).</span></li>
|
||
|
<li class="stepexpand"><span>Select option 4 (Failed and nonreporting hardware resources), and press Enter. Identify and record all resources that are switched between partitions. You may need to reassign or rename these
|
||
|
resources following the expansion unit conversion.</span></li>
|
||
|
<li class="stepexpand"><span>Type option 4 (remove) to remove any failed or nonreporting resources. If you receive a message saying <samp class="codeph">No failed or nonreporting logical hardware resources found</samp>, skip to step <a href="#rzamdrmvresources__rmvresourceconfirm">6</a>.</span></li>
|
||
|
<li class="stepexpand" id="rzamdrmvresources__rmvresourceconfirm"><a name="rzamdrmvresources__rmvresourceconfirm"><!-- --></a><span>Confirm removal of failed or nonreporting resources.</span></li>
|
||
|
<li class="stepexpand"><span>Press F6 (Print) to print the system configuration list.</span></li>
|
||
|
</ol>
|
||
|
</div>
|
||
|
<div>
|
||
|
<div class="familylinks">
|
||
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzamdexpanupgradelpardoc.htm" title="Ensure that the currently installed server and logical partitions are fully documented before the service representative arrives to perform the expansion unit conversion. Make sure that these documents represent the most recent configuration of the server and that no hardware changes have been made since printing the documentation. If changes are made before the service representative arrives, print the server and LPAR partition documentation again.">Document and prepare the server</a></div>
|
||
|
</div>
|
||
|
<div class="relconcepts"><strong>Related concepts</strong><br />
|
||
|
<div><a href="../rzamh/rzamhwhatuserids.htm">Service tools user ID</a></div>
|
||
|
</div>
|
||
|
<div class="reltasks"><strong>Related tasks</strong><br />
|
||
|
<div><a href="rzamdexpanupgradelpardoc.htm" title="Ensure that the currently installed server and logical partitions are fully documented before the service representative arrives to perform the expansion unit conversion. Make sure that these documents represent the most recent configuration of the server and that no hardware changes have been made since printing the documentation. If changes are made before the service representative arrives, print the server and LPAR partition documentation again.">Document and prepare the server</a></div>
|
||
|
<div><a href="rzamdhwupgradesiteprep.htm" title="Describes how to prepare for the server upgrade.">Prepare to upgrade the server</a></div>
|
||
|
<div><a href="rzamdhwupgradepreplpar.htm" title="Describes how to prepare for the server upgrade.">Prepare to upgrade the partitioned server</a></div>
|
||
|
</div>
|
||
|
</div>
|
||
|
</body>
|
||
|
</html>
|