ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzak3_5.4.0.1/rzak3rzak3pollitv.htm

59 lines
3.7 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="reference" />
<meta name="DC.Title" content="Parameters that control exchanges of information over local management interface" />
<meta name="abstract" content="This topic provides information about the polling interval (POLLITV) and full inquiry interval (FULLINQITV) parameters." />
<meta name="description" content="This topic provides information about the polling interval (POLLITV) and full inquiry interval (FULLINQITV) parameters." />
<meta name="DC.Relation" scheme="URI" content="rzak3rzak3lmi.htm" />
<meta name="DC.Relation" scheme="URI" content="rzak3rzak3lmixchng.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzak3pollitv" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Parameters that control exchanges of information over local management
interface</title>
</head>
<body id="rzak3pollitv"><a name="rzak3pollitv"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Parameters that control exchanges of information over local management
interface</h1>
<div><p>This topic provides information about the polling interval (POLLITV)
and full inquiry interval (FULLINQITV) parameters.</p>
<div class="section"><p>The POLLITV and FULLINQITV parameters control the
exchange of information over the local management interface (LMI).</p>
</div>
<div class="section"> <ul><li>The POLLITV parameter represents the frame-relay T391
timer. It sets the interval at which the terminal equipment (TE) sends a status
inquiry message to the frame handler (FH). You can set the POLLITV parameter
to any value between 5 and 30 seconds. The default value is 10 seconds.</li>
<li>The FULLINQITV parameter represents the frame-relay N391 count. The FULLINQITV
parameter sets the interval at which the TE requests full status from the
FH. You can set the FULLINQITV parameter to any value between 1 and 255 cycles.
The default value is 6 cycles.</li>
</ul>
</div>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzak3rzak3lmi.htm" title="This topic provides information about parameters specifying how status information is exchanged between the frame-relay network and the systems attached to it.">Local management interface</a></div>
</div>
<div class="relref"><strong>Related reference</strong><br />
<div><a href="rzak3rzak3lmixchng.htm" title="This topic provides information about the keep-alive exchange and permanent virtual circuit (PVC) status change.">Local management interface exchanges</a></div>
</div>
</div>
</body>
</html>