80 lines
4.8 KiB
HTML
80 lines
4.8 KiB
HTML
|
<?xml version="1.0" encoding="utf-8"?>
|
||
|
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
|
||
|
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
||
|
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
|
||
|
<head>
|
||
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
||
|
<meta name="dc.language" scheme="rfc1766" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<meta name="dc.date" scheme="iso8601" content="2005-09-13" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
|
||
|
<meta name="security" content="public" />
|
||
|
<meta name="Robots" content="index,follow"/>
|
||
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
||
|
<title>Hot spare between server hardware</title>
|
||
|
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="ic.css" />
|
||
|
</head>
|
||
|
<body>
|
||
|
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
|
||
|
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
|
||
|
|
||
|
<img src="delta.gif" alt="Start of change" />
|
||
|
<a name="rzahqhotsparebetw"></a>
|
||
|
<h2 id="rzahqhotsparebetw">Hot spare between server hardware</h2>
|
||
|
<p>iSeries™ and xSeries® integration and storage virtualization provide
|
||
|
options that can enable you to enhance the reliability and recoverability
|
||
|
of your Windows server environment. If a Windows server fails, you can quickly
|
||
|
and easily switch the server's storage spaces to another hot spare xSeries server without
|
||
|
restarting your iSeries server. This may reduce the total number of Intel® servers
|
||
|
needed to provide increased availability. It also adds flexibility by enabling
|
||
|
one spare server to be used to protect multiple production servers.</p>
|
||
|
<a name="wq276"></a>
|
||
|
<div class="notetitle" id="wq276">Note:</div>
|
||
|
<div class="notebody">For iSCSI attached servers, the iSCSI local host adapters
|
||
|
can also take advantage of hot spare support. See <a href="rzahqhotsparebetweeniscsi.htm#rzahqhotsparebetweeniscsi">Hot spare between iSCSI local host adapters</a>.</div>
|
||
|
<p>The procedures for hot sparing an integrated server's hardware are shown
|
||
|
below.</p>
|
||
|
<p><span class="bold">Using iSeries Navigator:</span></p>
|
||
|
<ol type="1">
|
||
|
<li>Expand <span class="bold">Integrated Server Administration</span>.</li>
|
||
|
<li>Select <span class="bold">Servers</span>.</li>
|
||
|
<li>If the server for which you want to swap hardware is not already shut
|
||
|
down:
|
||
|
<ul>
|
||
|
<li>Right-click the server and select <span class="bold">Shut Down</span>.</li>
|
||
|
<li>Click <span class="bold">Shut Down</span> on the confirmation panel.</li></ul></li>
|
||
|
<li>Change the server configuration to point to the hot spare server hardware.
|
||
|
<ol type="a">
|
||
|
<li>Right-click the server and select <span class="bold">Properties</span>.</li>
|
||
|
<li>Select the <span class="bold">System</span> tab and change one of the following:
|
||
|
<ul>
|
||
|
<li>For non-iSCSI servers, select the new <span class="bold">Resource name and
|
||
|
type</span>.</li>
|
||
|
<li>For iSCSI servers select the new <span class="bold">Remote system configuration
|
||
|
name</span>.</li></ul></li></ol>Click <span class="bold">OK</span>.</li>
|
||
|
<li>To start the integrated server, right-click the server and select <span class="bold">Start</span>.</li></ol>
|
||
|
<p><span class="bold">Using the character-based interface:</span></p>
|
||
|
<ol type="1">
|
||
|
<li>If the server for which you want to swap hardware is not already varied
|
||
|
off, use the <span class="bold">Vary Configuration (VRYCFG)</span> command to
|
||
|
vary it off.</li>
|
||
|
<li>To change the server configuration to point to the hot spare server hardware,
|
||
|
use the <span class="bold">Change Network Server Desc (CHGNWSD)</span> command
|
||
|
to change one of the following:
|
||
|
<ul>
|
||
|
<li>For non-iSCSI servers, change the value for the <span class="bold">Resource
|
||
|
name (RSRCNAME)</span> parameter to specify the new IXS or IXA hardware resource
|
||
|
name.</li>
|
||
|
<li>For iSCSI servers, change the value for the <span class="bold">Remote system
|
||
|
name</span> element of the <span class="bold">Network server configuration (NWSCFG)</span> parameter to specify the new remote system network server configuration
|
||
|
object name.</li></ul></li>
|
||
|
<li>To start the integrated server, use the <span class="bold">Vary Configuration
|
||
|
(VRYCFG)</span> command.</li></ol><img src="deltaend.gif" alt="End of change" />
|
||
|