ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzahc_5.4.0.1/lpp.htm

248 lines
15 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="Replacing the licensed programs" />
<meta name="abstract" content="Follow these steps to replace licensed programs." />
<meta name="description" content="Follow these steps to replace licensed programs." />
<meta name="DC.Relation" scheme="URI" content="manual.htm" />
<meta name="DC.Relation" scheme="URI" content="boss.htm" />
<meta name="DC.Relation" scheme="URI" content="ver3.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2004, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2004, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="lpp" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Replacing the licensed programs</title>
</head>
<body id="lpp"><a name="lpp"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Replacing the licensed programs</h1>
<div><p>Follow these steps to replace licensed programs.</p>
<div class="section"></div>
<ol><li class="stepexpand"><span>Begin this task at the Sign On display.</span> <div class="p"><pre class="screen"> Sign On
System. . . . . . : XXXX
Subsystem . . . . : XXXX
Display . . . . . : XXXXXXXX
User. . . . . . . . . . . . . . . . <span>QSECOFR</span>
Password . . . . . . . . . . . . .
Program/procedure . . . . . . . . . ________
Menu . . . . . . . . . . . . . . . ________
Current library . . . . . . . . . . ________
</pre>
Type the following and press Enter: <ul class="simple"><li>User: <samp class="codeph">QSECOFR</samp></li>
<li>Password: (Enter password, if required.)</li>
</ul>
</div>
</li>
<li class="stepexpand" id="lpp__iploptm"><a name="lpp__iploptm"><!-- --></a><span>The IPL Options display appears.</span> <pre class="screen"> IPL Options
Type choices, press Enter.
System date . . . . . . . . . . . . . . . XX / XX / XX MM / DD / YY
System time . . . . . . . . . . . . . . . XX : XX : XX HH : MM : SS
System time zone . . . . . . . . . . . . <span>Q0000UTC</span> F4 for list
Clear job queues. . . . . . . . . . . . . <span>N</span> Y=Yes, N=No
Clear output queues . . . . . . . . . . . <span>N</span> Y=Yes, N=No
Clear incomplete job logs . . . . . . . . <span>N</span> Y=Yes, N=No
Start print writers . . . . . . . . . . . <span>Y</span> Y=Yes, N=No
Start system to restricted state . . . . <span>N</span> Y=Yes, N=No
Set major system options. . . . . . . . . <span>N</span> Y=Yes, N=No
Define or change system at IPL. . . . . . <span>N</span> Y=Yes, N=No
<strong>Last power-down operation was ABNORMAL</strong>
</pre>
<div class="note"><span class="notetitle">Notes:</span> <ol type="a"><li>Ignore the message on the bottom of the IPL Options display.</li>
<li>If you need to change system values, you can do so now. One example of
a system value that you might change is the value for the security level (QSECURITY)
system value. <p>Another example is the scan control (QSCANFSCTL)
system value. If you have not already done so, consider specifying *NOPOSTRST
for the QSCANFSCTL system value to minimize future scanning of some objects
that are restored during the installation of licensed programs in the following
steps. For more information on scanning and the system value settings, see
the topic <a href="../ifs/rzaaxscan.htm">Scanning
support</a> .</p>
<p>Type <samp class="codeph">Y</samp> for
the <em>Define or change the system at IPL</em> prompt. Follow the instructions
on the displays.</p>
</li>
</ol>
</div>
<div class="p">Type the following and press Enter: <ul><li>System date: (Use the current date.)</li>
<li>System time: (Use the current time, 24-hour clock.)</li>
<li>System time zone: (Verify that it is correct or press F4 to select a time
zone.)</li>
<li>Set major system options: <samp class="codeph">N</samp></li>
</ul>
</div>
</li>
<li class="stepexpand"><span>The Edit Rebuild of Access Paths display could
be shown. If it is, press Enter to continue.</span></li>
<li class="stepexpand"><span>Additional display messages could be shown.
</span> <p>Press Enter after each message to continue.</p>
</li>
<li class="stepexpand"><span>The <span class="keyword">i5/OS™</span> Main
Menu (or the menu you chose as an initial menu) appears on your console.</span> <div class="p"><ol type="a"><li>Type <samp class="codeph">CHGMSGQ QSYSOPR *BREAK SEV(60)</samp> and press Enter.</li>
<li>A message display could appear. Press Enter.</li>
<li>Type <samp class="codeph">ENDSBS *ALL *IMMED</samp> and press Enter.</li>
<li>When the following message appears, press Enter to continue: <pre>ENDSBS SBS(*ALL) command being processed</pre>
</li>
<li>The message <samp class="codeph">System ended to restricted condition</samp> appears.
Press Enter to continue.</li>
<li>Type <samp class="codeph">CHGMSGQ QSYSOPR SEV(95)</samp> and press Enter.</li>
<li>A message display could appear. Press Enter.</li>
</ol>
</div>
</li>
<li class="stepexpand"><span>The <span class="keyword">i5/OS</span> Main
Menu (or the menu you chose as an initial menu) appears on your console.</span> <p>Type <samp class="codeph">GO LICPGM</samp> and press Enter.</p>
</li>
<li class="stepexpand"><span>The Work with Licensed Programs display appears. </span> <pre class="screen"> LICPGM Work with Licensed Programs
System: XXXX
Select one of the following:
Manual Install
1. Install all
</pre>
<p>Type <samp class="codeph">1</samp>, and press Enter.</p>
</li>
<li class="stepexpand"><span>The Manual Install display appears. </span> <pre class="screen"> Manual Install
System: XXXX
Type choices, press Enter.
Install option . . . <span>1</span> 1=Installed products
2=All products
3=New products
Installation device <span>OPT01</span> Name
Replace if current <span>N</span> Y=Yes
N=No
Nonaccepted agreement <span>2</span> 1=Do not install licensed program
2=Display software agreement
Automatic IPL . . . <span>N</span> Y=Yes
N=No
</pre>
<div class="p">Type
the following and press Enter: <ul><li>Install option: <samp class="codeph">1</samp></li>
<li>Installation device: <samp class="codeph">OPT01</samp> (See notes that follow.)</li>
<li>Replace if current: <samp class="codeph">N</samp></li>
<li>Nonaccepted agreement: <samp class="codeph">2</samp> (See note that follows.)</li>
<li>Automatic IPL: <samp class="codeph">N</samp></li>
</ul>
<div class="note"><span class="notetitle">Notes:</span> <ul><li>If you created a customized installation list, select install option 4
(Installed and additionally selected products). This option only appears if
you used the LICPGM menu option to Prepare for Install, which is described
in <a href="rzahcswsvfycustlist.htm#rzahcswsvfycustlist">Required: Creating a custom list of software to install</a>.</li>
<li>In this example, the installation device is OPT01. If you are using a
different naming convention, use the name you have assigned to the installation
device.</li>
<li>If you are using your own distribution media, select <samp class="codeph">2</samp> for
the <em>Install option</em> field. For the <em>Replace if current</em> field,
type <samp class="codeph">Y</samp>. </li>
<li>If you have not previously accepted software agreements for licensed programs
that you plan to install, option 2 displays the software agreements for acceptance
as each licensed program is installed. This will increase the length of your
installation time. If you want to accept the software agreements now, go to
step <a href="contlp.htm#contlp__wrklpdisplay">5</a> and then return
here. </li>
</ul>
</div>
</div>
</li>
<li class="stepexpand"><span>Status displays might appear. These displays
show the status of the licensed programs and language objects as they install
on the system. You do not need to respond to these status displays. </span> <pre class="screen"> Installing Licensed Programs
System: XXXX
Licensed programs processed . . . . . . . . . . : 0 of XXX
Licensed program install in progress
</pre>
<p>The following display is an example of the display that appears
during the installation process.</p>
<pre class="screen"> Installing Licensed Programs
System: XXXX
Licensed programs processed . . . . . . . . . . : X of XXX
Licensed
Program Option Description Type
5722SS1 2 Online Information 2924
</pre>
<p>This
display shows which licensed programs and optional parts of licensed programs
are being processed. After the *PGM objects and *LNG objects are processed,
the display shows the total number of licensed programs processed.</p>
</li>
<li class="stepexpand"><span>If a message similar to the following appears, load the next media
volume that contains licensed program products, and continue the installation.
When you are installing from optical media, wait for the In Use indicator
to go out before you respond to the message.</span> <pre class="screen"> Display Messages
System: XXXX
Queue . . . . . : QSYSOPR Program . . . . : *DSPMSG
Library . . . : QSYS Library . . . :
Severity . . . . : 95 Delivery . . . : *BREAK
Type reply (if required), press Enter.
Load the next volume in optical device OPT01 (X G)
Reply . . . . <strong>G</strong>
</pre>
<p>Type <samp class="codeph">G</samp> and press Enter. </p>
<p>After you load
each volume, type <samp class="codeph">G</samp> and press Enter. If there are no more
volumes to load that contain licensed programs, or if you want to end the
loading process, type <samp class="codeph">X</samp> and press Enter.</p>
</li>
<li class="stepexpand" id="lpp__requireacceptance"><a name="lpp__requireacceptance"><!-- --></a><span>If a licensed program requires acceptance
of a software agreement, the Software Agreements display appears. Do either
of the following:</span> <ul><li>Press F14 to accept the agreement and allow the licensed program to continue
installing.</li>
<li>Press F16 to decline the agreement and end the installation of that licensed
program.</li>
</ul>
</li>
<li class="stepexpand"><span>The Work with Licensed Programs display appears on your console
when the installation process is completed. One of the following messages
appears on the bottom of the Work with Licensed Programs display: </span> <ul><li><samp class="codeph">Work with licensed programs function has completed.</samp></li>
<li><samp class="codeph">Work with licensed programs function not complete.</samp></li>
</ul>
</li>
</ol>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="manual.htm" title="Follow these instructions to use the manual installation method to replace the Licensed Internal Code, IBM i5/OS, and licensed programs currently installed on your system with the V5R4 release.">Upgrading or replacing software using manual installation</a></div>
<div class="previouslink"><strong>Previous topic:</strong> <a href="boss.htm" title="Follow these steps to replace the IBM i5/OS operating system.">Replacing the operating system</a></div>
<div class="nextlink"><strong>Next topic:</strong> <a href="ver3.htm" title="Follow these steps to verify that you have successfully completed the installation.">Verifying completion of manual installation</a></div>
</div>
</div>
</body>
</html>