<a name="CHGLINSDLC.Top_Of_Page"></a>
<h2>Change Line Desc (SDLC) (CHGLINSDLC)</h2>
<table width="100%">
<tr>
<td valign="top" align="left"><b>Where allowed to run: </b>All environments (*ALL)<br>
<b>Threadsafe: </b>No
</td>
<td valign="top" align="right">
<a href="#CHGLINSDLC.PARAMETERS.TABLE">Parameters</a><br>
<a href="#CHGLINSDLC.COMMAND.EXAMPLES">Examples</a><br>
<a href="#CHGLINSDLC.ERROR.MESSAGES">Error messages</a></td>
</tr>
</table>
<div> <a name="CHGLINSDLC"></a>
<p>The Change Line Description (SDLC) (CHGLINSDLC) command changes a line description for an SDLC line.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div>
<h3><a name="CHGLINSDLC.PARAMETERS.TABLE">Parameters</a></h3>
<table border="1" cellpadding="4" cellspacing="0">
<!-- col1="10" col2="15" col3="30" col4="10" -->
<tr>
<th bgcolor="aqua" valign="bottom" align="left">Keyword</th>
<th bgcolor="aqua" valign="bottom" align="left">Description</th>
<th bgcolor="aqua" valign="bottom" align="left">Choices</th>
<th bgcolor="aqua" valign="bottom" align="left">Notes</th>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.LIND"><b>LIND</b></a></td>
<td valign="top">Line description</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Required, Key, Positional 1</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.RSRCNAME"><b>RSRCNAME</b></a></td>
<td valign="top">Resource names</td>
<td valign="top">Single values: <b><u>*SAME</u></b><br>Other values (up to 6 repetitions): <i>Name</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.ONLINE"><b>ONLINE</b></a></td>
<td valign="top">Online at IPL</td>
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.ACTSNBU"><b>ACTSNBU</b></a></td>
<td valign="top">Activate swt network backup</td>
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.VRYWAIT"><b>VRYWAIT</b></a></td>
<td valign="top">Vary on wait</td>
<td valign="top">15-180, <b><u>*SAME</u></b>, *NOWAIT</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.NRZI"><b>NRZI</b></a></td>
<td valign="top">NRZI data encoding</td>
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.MAXCTL"><b>MAXCTL</b></a></td>
<td valign="top">Maximum controllers</td>
<td valign="top">1-254, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.CLOCK"><b>CLOCK</b></a></td>
<td valign="top">Clocking</td>
<td valign="top"><b><u>*SAME</u></b>, *MODEM, *LOOP, *INVERT</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.LINESPEED"><b>LINESPEED</b></a></td>
<td valign="top">Line speed</td>
<td valign="top"><b><u>*SAME</u></b>, 600, 1200, 2400, 4800, 7200, 9600, 14400, 19200, 48000, 56000, 57600, 64000, 112000, 128000, 168000, 192000, 224000, 256000, 280000, 320000, 336000, 384000, 392000, 448000, 504000, 512000, 560000, 576000, 616000, 640000, 672000, 704000, 728000, 768000, 784000, 832000, 840000, 896000, 952000, 960000, 1008000, 1024000, 1064000, 1088000, 1120000, 1152000, 1176000, 1216000, 1232000, 1280000, 1288000, 1344000, 1400000, 1408000, 1456000, 1472000, 1512000, 1536000, 1568000, 1600000, 1624000, 1664000, 1680000, 1728000, 1736000, 1792000, 1856000, 1920000, 1984000, 2048000</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.MODEM"><b>MODEM</b></a></td>
<td valign="top">Modem type supported</td>
<td valign="top"><b><u>*SAME</u></b>, *NORMAL, *V54, *IBMWRAP, *IBMLPDA1, *IBMLPDA2</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.MODEMRATE"><b>MODEMRATE</b></a></td>
<td valign="top">Modem data rate select</td>
<td valign="top"><b><u>*SAME</u></b>, *FULL, *HALF</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SWTCNN"><b>SWTCNN</b></a></td>
<td valign="top">Switched connection type</td>
<td valign="top"><b><u>*SAME</u></b>, *BOTH, *ANS, *DIAL</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.AUTOANS"><b>AUTOANS</b></a></td>
<td valign="top">Autoanswer</td>
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.AUTODIAL"><b>AUTODIAL</b></a></td>
<td valign="top">Autodial</td>
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.MDMINZCMD"><b>MDMINZCMD</b></a></td>
<td valign="top">Modem init command string</td>
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *NONE</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.DIALCMD"><b>DIALCMD</b></a></td>
<td valign="top">Dial command type</td>
<td valign="top"><b><u>*SAME</u></b>, *NONE, *V25BIS</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.ACRSRCNAME"><b>ACRSRCNAME</b></a></td>
<td valign="top">Autocall resource name</td>
<td valign="top"><i>Name</i>, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SHMCALLTMR"><b>SHMCALLTMR</b></a></td>
<td valign="top">SHM call timer</td>
<td valign="top">1-60, <b><u>*SAME</u></b>, *NONE</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SHMMAXCNN"><b>SHMMAXCNN</b></a></td>
<td valign="top">SHM maximum connect timer</td>
<td valign="top">1-254, *NOMAX, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SHMANSDLY"><b>SHMANSDLY</b></a></td>
<td valign="top">SHM answer delay timer</td>
<td valign="top">1-254, *NOMAX, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SHMCALLFMT"><b>SHMCALLFMT</b></a></td>
<td valign="top">SHM call format</td>
<td valign="top">0-15, <b><u>*SAME</u></b>, *DNIC, *DCC</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SHMACC"><b>SHMACC</b></a></td>
<td valign="top">SHM access code</td>
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *NONE</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.CALLNBR"><b>CALLNBR</b></a></td>
<td valign="top">Calling number</td>
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *NONE</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.STNADR"><b>STNADR</b></a></td>
<td valign="top">Station address</td>
<td valign="top">01-FE, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.CNNPOLLRTY"><b>CNNPOLLRTY</b></a></td>
<td valign="top">Connect poll retry</td>
<td valign="top">0-64, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.CNNTMR"><b>CNNTMR</b></a></td>
<td valign="top">Connect timer</td>
<td valign="top">1-32767, <b><u>*SAME</u></b>, *NOMAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SHORTTMR"><b>SHORTTMR</b></a></td>
<td valign="top">Short timer</td>
<td valign="top">10-600, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.LONGTMR"><b>LONGTMR</b></a></td>
<td valign="top">Long timer</td>
<td valign="top">100-6000, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SHORTRTY"><b>SHORTRTY</b></a></td>
<td valign="top">Short retry</td>
<td valign="top">0-254, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.LONGRTY"><b>LONGRTY</b></a></td>
<td valign="top">Long retry</td>
<td valign="top">0-254, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.CPSRTY"><b>CPSRTY</b></a></td>
<td valign="top">Call progress signal retry</td>
<td valign="top">Single values: <b><u>*SAME</u></b>, *NONE<br>Other values (up to 11 repetitions): *CPS41, *CPS42, *CPS43, *CPS44, *CPS45, *CPS46, *CPS47, *CPS48, *CPS49, *CPS71, *CPS72</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.MAXFRAME"><b>MAXFRAME</b></a></td>
<td valign="top">Maximum frame size</td>
<td valign="top"><b><u>*SAME</u></b>, 265, 521, 1033, 2057</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.THRESHOLD"><b>THRESHOLD</b></a></td>
<td valign="top">Error threshold level</td>
<td valign="top"><b><u>*SAME</u></b>, *OFF, *MIN, *MED, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.DUPLEX"><b>DUPLEX</b></a></td>
<td valign="top">Duplex</td>
<td valign="top"><b><u>*SAME</u></b>, *HALF, *FULL</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.MODULUS"><b>MODULUS</b></a></td>
<td valign="top">Modulus</td>
<td valign="top"><b><u>*SAME</u></b>, 8, 128</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.MAXOUT"><b>MAXOUT</b></a></td>
<td valign="top">Maximum outstanding frames</td>
<td valign="top">1-28, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.INACTTMR"><b>INACTTMR</b></a></td>
<td valign="top">Inactivity timer</td>
<td valign="top">150-4200, <b><u>*SAME</u></b>, *NOMAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.POLLRSPDLY"><b>POLLRSPDLY</b></a></td>
<td valign="top">Poll response delay</td>
<td valign="top">0-2048, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.NPRDRCVTMR"><b>NPRDRCVTMR</b></a></td>
<td valign="top">Nonproductive receive timer</td>
<td valign="top">160-4200, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.IDLTMR"><b>IDLTMR</b></a></td>
<td valign="top">Idle timer</td>
<td valign="top">5-300, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.CNNPOLLTMR"><b>CNNPOLLTMR</b></a></td>
<td valign="top">Connect poll timer</td>
<td valign="top">2-300, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.POLLPAUSE"><b>POLLPAUSE</b></a></td>
<td valign="top">Poll cycle pause</td>
<td valign="top">0-2048, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.FRAMERTY"><b>FRAMERTY</b></a></td>
<td valign="top">Frame retry</td>
<td valign="top">0-64, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.FAIRPLLTMR"><b>FAIRPLLTMR</b></a></td>
<td valign="top">Fair polling timer</td>
<td valign="top">5-60, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.DSRDRPTMR"><b>DSRDRPTMR</b></a></td>
<td valign="top">Data Set Ready drop timer</td>
<td valign="top">3-60, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.AUTOANSTYP"><b>AUTOANSTYP</b></a></td>
<td valign="top">Autoanswer type</td>
<td valign="top"><b><u>*SAME</u></b>, *DTR, *CDSTL</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.CTSTMR"><b>CTSTMR</b></a></td>
<td valign="top">Clear To Send timer</td>
<td valign="top">10-60, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.RMTANSTMR"><b>RMTANSTMR</b></a></td>
<td valign="top">Remote answer timer</td>
<td valign="top"><b><u>*SAME</u></b>, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.LINKSPEED"><b>LINKSPEED</b></a></td>
<td valign="top">Link speed</td>
<td valign="top"><b><u>*SAME</u></b>, *INTERFACE, *MIN, 1200, 2400, 4800, 7200, 9600, 14400, 19200, 48000, 56000, 64000, 112000, 128000, 168000, 192000, 224000, 256000, 280000, 320000, 336000, 384000, 448000, 499000, 576000, 614000, 691000, 768000, 845000, 922000, 998000, 1075000, 1152000, 1229000, 1382000, 1536000, 1690000, 1843000, 1997000, 4M, 10M, 16M, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.COSTCNN"><b>COSTCNN</b></a></td>
<td valign="top">Cost/connect time</td>
<td valign="top">0-255, <b><u>*SAME</u></b>, *CNN</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.COSTBYTE"><b>COSTBYTE</b></a></td>
<td valign="top">Cost/byte</td>
<td valign="top">0-255, <b><u>*SAME</u></b>, *CNN</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.SECURITY"><b>SECURITY</b></a></td>
<td valign="top">Security for line</td>
<td valign="top"><b><u>*SAME</u></b>, *NONSECURE, *PKTSWTNET, *UNDGRDCBL, *SECURECND, *GUARDCND, *ENCRYPTED, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.PRPDLY"><b>PRPDLY</b></a></td>
<td valign="top">Propagation delay</td>
<td valign="top"><b><u>*SAME</u></b>, *MIN, *LAN, *TELEPHONE, *PKTSWTNET, *SATELLITE, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.USRDFN1"><b>USRDFN1</b></a></td>
<td valign="top">User-defined 1</td>
<td valign="top">0-255, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.USRDFN2"><b>USRDFN2</b></a></td>
<td valign="top">User-defined 2</td>
<td valign="top">0-255, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.USRDFN3"><b>USRDFN3</b></a></td>
<td valign="top">User-defined 3</td>
<td valign="top">0-255, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CHGLINSDLC.CMNRCYLMT"><b>CMNRCYLMT</b></a></td>
<td valign="top">Recovery limits</td>
<td valign="top">Single values: <b><u>*SAME</u></b>, *SYSVAL<br>Other values: <i>Element list</i></td>
<td valign="top" rowspan="3">Optional</td>
</tr>
<tr>
<td valign="top">Element 1: Count limit</td>
<td valign="top">
0-99</td>
</tr>
<tr>
<td valign="top">Element 2: Time interval</td>
<td valign="top">
0-120</td>
</tr>
<tr>
<td valign="top"><a href="#CHGLINSDLC.TEXT"><b>TEXT</b></a></td>
<td valign="top">Text 'description'</td>
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *BLANK</td>
<td valign="top">Optional</td>
</tr>
</table>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
</div>
<div> <a name="CHGLINSDLC.LIND"></a>
<h3>Line description (LIND)</h3>
<p>Specifies the name of the line description
</p>
<p>This is a required parameter.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.RSRCNAME"></a>
<h3>Resource names (RSRCNAME)</h3>
<p>Specifies the resource name that identifies the hardware this description represents. Use the WRKHDWRSC command to determine the resource name.
</p>
<p>This is a required parameter.
</p>
<p>You can enter multiple values for this parameter.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.ONLINE"></a>
<h3>Online at IPL (ONLINE)</h3>
<p>Specifies whether this object is automatically varied on at initial program load (IPL).
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*YES</b></dt>
<dd>The line is automatically varied on at initial program load (IPL).
</dd>
<dt><b>*NO</b></dt>
<dd>This line is not automatically varied on at IPL.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.ACTSNBU"></a>
<h3>Activate swt network backup (ACTSNBU)</h3>
<p>Specifies, for modems that support the switched network backup (SNBU) feature and that are not IBM 386x, 586x, or 786x models, whether the SNBU feature is activated or deactivated. The local modem and remote modem must both support the SNBU to activate it. IBM 386x, 586x, and 786x models are activated with a hardware switch only. This feature lets you bypass a broken nonswitched connection (nonswitched line) by establishing a switched connection.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>This value does not change from the value previously specified either on this parameter or on the SNBU parameter of the command creating the line description.
</dd>
</dl>
<dl>
<dt><b>*NO</b></dt>
<dd>The SNBU feature is not used.
</dd>
</dl>
<dl>
<dt><b>*YES</b></dt>
<dd>The SNBU feature is activated. You must also specify a value of *YES for the <b>Activate swt network backup (ACTSNBU)</b> parameter for the controller.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.VRYWAIT"></a>
<h3>Vary on wait (VRYWAIT)</h3>
<p>Specifies whether the line is varied on asynchronously or synchronously. For synchronous vary on, this parameter specifies how long the system waits for the vary on to complete.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NOWAIT</b></dt>
<dd>The system does not wait for vary on completion. The line is varied on asynchronously.
</dd>
<dt><b><i>vary-on-wait</i></b></dt>
<dd>Specify the time (in seconds) to wait. Valid values range from 15 through 180. The system waits until the line is varied on, or until the specified time passes, before completing the Vary Configuration (VRYCFG) command.
</dd>
</dl>
<p><b>Notes:</b>
</p>
<ol>
<li>When ONLINE(*YES) is used, specifying a wait time in the line description affects system IPL time. In such cases, system IPL time is influenced by the amount of time required to synchronously vary on the line or reach the wait-time value.
</li>
<li>The time required to vary on a line is the time it takes to:
<ul>
<li>Put tasks in place to manage the line
</li>
<li>Activate the communications I/O processor (IOP), including downloading the IOP model-unique Licensed Internal Code
</li>
<li>Establish the communications tasks and processes
</li>
</ul>
</li>
</ol>
<p>Normal vary-on time ranges from 5 through 45 seconds, but can be longer, depending on the system, line protocol, and other factors.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.NRZI"></a>
<h3>NRZI data encoding (NRZI)</h3>
<p>Specifies whether non-return-to-zero-inverted (NRZI) data coding is to be used for modems that are sensitive to certain bit patterns in the data stream. This ensures that the signal does not remain the same for an extended period of time.
</p>
<p>
<b>Note: </b>All data communications equipment on the line must use the same transmission method.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*YES</b></dt>
<dd>NRZI data coding is used.
</dd>
<dt><b>*NO</b></dt>
<dd>NRZI data coding is not used.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.MAXCTL"></a>
<h3>Maximum controllers (MAXCTL)</h3>
<p>Specifies the maximum number of controllers that the line supports.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>1</b></dt>
<dd>One controller is supported. Use the default (1) for:
<ul>
<li>Nonswitched point-to-point and switched point-to-point connection types
</li>
<li>Nonswitched point-to-point and multipoint connection types communicating with a host system using duplex, two-way simultaneous data transfer. (The host system specifies duplex data transfer in its NCP generation by specifying LINE ADDRESS=(nnn,FULL) on the LINE macroinstruction.)
</li>
<li>Short-hold mode lines specified with ROLE(*SEC) and SHMNODE(*T20)
</li>
</ul>
<p>Short-hold mode lines specified with ROLE(*PRI) or ROLE(*NEG) can support up to 64 controllers.
</p>
</dd>
<dt><b><i>maximum-controllers</i></b></dt>
<dd>Specify value ranging from 1 to 254. The number must be large enough to account for all of the controllers that are currently active to this line, and for those controllers you know will be attached in the near future.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CLOCK"></a>
<h3>Clocking (CLOCK)</h3>
<p>Specifies how the clocking function for the line is provided.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*MODEM</b></dt>
<dd>The clocking function for the line is provided by the modem.
</dd>
<dt><b>*LOOP</b></dt>
<dd>The receiving clock provided by the modem data circuit-terminating equipment (DCE) is looped back to the modem DCE on the system data terminal equipment (DTE) transmitting clock. This option can be used to provide high speed data transmission when the modem DCE supports such an option. The valid interfaces for *LOOP are *V35, *X21BISV35, and *RS449V36.
</dd>
<dt><b>*INVERT</b></dt>
<dd>The transmit clock provided by the modem data circuit-terminating equipment (DCE) is inverted before use. This option can be used when having problems with high speed data transmission and the modem (DCE) does not support looped clocking. The valid interfaces for *INVERT are *V35, *X21, *X21BISV35, and *RS449V36.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.LINESPEED"></a>
<h3>Line speed (LINESPEED)</h3>
<p>Specifies the line speed in bits per second (bps).
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>9600</b></dt>
<dd>9600 bps is used.
</dd>
<dt><b><i>line-speed</i></b></dt>
<dd>Specify the line speeds. Valid lines speeds are: 600, 1200, 2400 4800, 7200, 9600, 14400, 19200, 48000, 56000, 57600, 64000, 112000, 128000, 168000, 192000, 224000, 256000, 280000, 320000, 336000, 384000, 392000, 448000, 504000, 512000, 560000, 576000, 616000, 640000, 672000, 704000, 728000, 768000, 784000, 832000, 840000, 896000, 952000, 960000, 1008000, 1024000, 1064000, 1088000, 1120000, 1152000, 1176000, 1216000, 1232000, 1280000, 1288000, 1344000, 1400000, 1408000, 1456000, 1472000, 1512000, 1536000, 1568000, 1600000, 1624000, 1664000, 1680000, 1728000, 1736000, 1792000, 1856000, 1920000, 1984000, or 2048000 bits per second.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.MODEM"></a>
<h3>Modem type supported (MODEM)</h3>
<p>Specifies the type of modem supported on the communications line. Refer to the modem manual to determine the appropriate value to select.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NORMAL</b></dt>
<dd>No attempt is made to run diagnostic tests to your modem.
</dd>
<dt><b>*V54</b></dt>
<dd>Certain types of diagnostic tests (as defined by the CCITT recommendations) are run to your modem. This system supports CCITT V.54 loop 3, (a local loop back,) and loop 2, (which is a remote loop back).
</dd>
<dt><b>*IBMWRAP</b></dt>
<dd>An IBM modem with wrap test capabilities is used on the communications line.
</dd>
<dt><b>*IBMLPDA1</b></dt>
<dd>An IBM modem with Link Problem Determination Aid-1 (LPDA-1) is used on the line.
</dd>
</dl>
<dl>
<dt><b>*IBMLPDA2</b></dt>
<dd>An IBM modem with Link Problem Determination Aid-2 (LPDA-2) is used on the line.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.MODEMRATE"></a>
<h3>Modem data rate select (MODEMRATE)</h3>
<p>Specifies the speed at which the line operates if the modem has the data rate select feature.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*FULL</b></dt>
<dd>The line operates at the full rate of the modem.
</dd>
<dt><b>*HALF</b></dt>
<dd>The line operates at half the full rate of the modem.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SWTCNN"></a>
<h3>Switched connection type (SWTCNN)</h3>
<p>Specifies whether the switched (Async, BSC, SDLC, or IDLC) line or switched network backup (Async, BSC, or SDLC) line is used for incoming calls, outgoing calls, or both.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*BOTH</b></dt>
<dd>The line is used for both incoming and outgoing calls.
</dd>
</dl>
<dl>
<dt><b>*ANS</b></dt>
<dd>The line is used for incoming calls only.
</dd>
</dl>
<dl>
</dl>
<dl>
<dt><b>*DIAL</b></dt>
<dd>The line is used for outgoing calls only.
</dd>
</dl>
<dl>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.AUTOANS"></a>
<h3>Autoanswer (AUTOANS)</h3>
<p>Specifies, for switched or switched network backup lines (Async, BSC, SDLC, or X.25 line), whether the system automatically answers a call from a remote system to establish the connection, or whether the system operator manually answers the call and places the modem in data mode.
</p>
<p>
<b>Note: </b>*YES is a valid option only if the modem has the automatic answer feature.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*YES</b></dt>
<dd>The incoming call is automatically answered by the automatic answer feature.
</dd>
<dt><b>*NO</b></dt>
<dd>The incoming call must be manually answered.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.AUTODIAL"></a>
<h3>Autodial (AUTODIAL)</h3>
<p>Specifies, for switched lines, whether the system automatically calls a remote system to establish a connection or if the system operator must manually place the call.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NO</b></dt>
<dd>The line connection is made by manually dialing the X.25 network.
</dd>
<dt><b>*YES</b></dt>
<dd>The line connection is made by the system automatically dialing the X.25 network.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.MDMINZCMD"></a>
<h3>Modem init command string (MDMINZCMD)</h3>
<p>Specifies the modem initialization command string sent to set the modem.
</p>
<p>
<b>Note: </b>Valid only when INTERFACE(*INTMODEM) or INFTRFTYPE(*SYNCMODEM) is specified.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NONE</b></dt>
<dd>No command string is sent to the modem.
</dd>
</dl>
<dl>
<dt><b><i>command-string</i></b></dt>
<dd>Specifies up to 60 characters that represent the command string sent to the modem. Valid characters are upper case A thru Z, lower case a thru z, numbers 0 thru 9, and special characters:
</dd>
</dl>
<p>
<pre>
Period
Less than sign
Left parenthesis
Plus sign
Ampersand
Asterisk
Right parenthesis
Semicolon
Minus sign
Slash
Comma
Underline
Greater than sign
Question mark
Colon
Equal sign
Spaces
Number sign
Double quote
Exclamation point
At sign
Hat symbol
Percent
Left square bracket
Right square bracket
Back slash
</pre>
</p>
<p>
<b>Note: </b>The modem initialization string must begin with the two characters 'AT'.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.DIALCMD"></a>
<h3>Dial command type (DIALCMD)</h3>
<p>Specifies the type of dial command used to establish a switched connection with a remote system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NONE</b></dt>
<dd>No dial command is used. (An automatic call unit is used to establish the connection.)
</dd>
</dl>
<dl>
<dt><b>*V25BIS</b></dt>
<dd>V.25 bis is a recommendation which allows the use of one physical interface for call establishment and data transmission. It is referred to as a serial automatic call interface because the digits are presented serially on the link from the system to the modem.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.ACRSRCNAME"></a>
<h3>Autocall resource name (ACRSRCNAME)</h3>
<p>Specifies the automatic call resource name that describes the automatic call unit port that is used to establish a connection with a remote system. Use the Work with Hardware Resources (WRKHDWRSC) command to determine the resource name.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SHMCALLTMR"></a>
<h3>SHM call timer (SHMCALLTMR)</h3>
<p>Specifies the interval at which a connection is re-established on an X.21 short hold mode (SHM) line to verify the state of the remote system if no SHM reconnection has occurred in the specified interval. This parameter is valid only if *SHM is specified on the <b>Connection type (CNN)</b> parameter.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NONE</b></dt>
<dd>No call is made to verify the connection.
</dd>
<dt><b><i>short-hold-mode-call-timer</i></b></dt>
<dd>Specify an interval, from 1 to 60 minutes, at which a call is made to verify the connection.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SHMMAXCNN"></a>
<h3>SHM maximum connect timer (SHMMAXCNN)</h3>
<p>Specifies the amount of time the system allows a connection to continue if there are more controllers than there are available ports. The system clears the connection after the specified amount of time, delays further calls for the amount of time specified on the <b>SHM answer delay timer (SHMANSDLY)</b> parameter, and then makes any calls that had been waiting before re-calling the controller that was interrupted.
</p>
<p>
<b>Note: </b>This parameter is valid only if *PRI or *NEG is specified on the <b>Data link role (ROLE)</b> parameter and if *SHM is specified on the <b>Connection type (CNN)</b> parameter.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>8</b></dt>
<dd>The system waits eight seconds before checking for other controllers.
</dd>
</dl>
<dl>
<dt><b>*NOMAX</b></dt>
<dd>The timer is disabled.
</dd>
</dl>
<dl>
<dt><b><i>maximum-connect-timeout</i></b></dt>
<dd>Specify a value ranging from 1 through 254 seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SHMANSDLY"></a>
<h3>SHM answer delay timer (SHMANSDLY)</h3>
<p>Specifies the amount of time the system waits for controllers to call in before making outgoing calls. The SHM answer delay timer is started when one of the following is true:
</p>
<ul>
<li>The time specified by the SHM maximum connect timer (SHMMAXCNN parameter) has expired.
</li>
<li>A period of time equal to twice the value of the SHMMAXCNN parameter has elapsed with no opportunities for incoming calls to be received.
</li>
</ul>
<p>
<b>Note: </b>This parameter is valid only if *PRI or *NEG is specified on the <b>Data link role (ROLE)</b> parameter and if *SHM is specified on the <b>Connection type (CNN)</b> parameter.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>11</b></dt>
<dd>The system waits 1.1 seconds before making outgoing calls.
</dd>
</dl>
<dl>
<dt><b>*NOMAX</b></dt>
<dd>The timer is disabled.
</dd>
</dl>
<dl>
<dt><b><i>ans-delay-timeout</i></b></dt>
<dd>Specify a value ranging from 1 through 254 tenths of seconds. For example, 10 seconds equal 100 tenths of seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SHMCALLFMT"></a>
<h3>SHM call format (SHMCALLFMT)</h3>
<p>Specifies the format for the X.21 short hold mode line call number. This parameter is valid only if *SHM is specified on the <b>Connection type (CNN)</b> parameter.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*DNIC</b></dt>
<dd>The Data Network Identification Code (DNIC) is used.
</dd>
<dt><b>*DCC</b></dt>
<dd>The Data Country Code (DCC) is used.
</dd>
<dt><b><i>call-format</i></b></dt>
<dd>The length of the area code or country or region code portion of the SHM calling number. Specify a number from 0 to 15.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SHMACC"></a>
<h3>SHM access code (SHMACC)</h3>
<p>Specifies the access code for the X.21 short hold mode line. This parameter is valid only if *SHM is specified on the <b>Connection type (CNN)</b> parameter.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CALLNBR"></a>
<h3>Calling number (CALLNBR)</h3>
<p>Specifies the local telephone number of the line that is used for the V.25 bis Call Request with Identification (CRI) dial command. When V.25 bis CRI dialing is used, the system takes the called (connection) number (CNNNBR parameter ), adds a separator character (;), and puts the calling number at the end. The default, *NONE, indicates that Call Request Normal (CRN) is used.
</p>
<p>Specify the calling number only when the modem and network support the CRI dial command.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NONE</b></dt>
<dd>Call Request Normal (CRN) is used. CRN dialing sends only the connection number to the V.25 bis modem.
</dd>
</dl>
<dl>
<dt><b><i>calling-number</i></b></dt>
<dd>Specify the local telephone number if V.25 bis CRI dialing is required. The number can be up to 32 characters in length. See your modem documentation to determine the values allowed by the modem.
</dd>
</dl>
<p>
<b>Note: </b>Specify the calling number only if both the modem and network support the V.25 bis CRI dial command.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.STNADR"></a>
<h3>Station address (STNADR)</h3>
<p>Specifies, for a switched secondary or negotiable line, the hexadecimal station address to which the local system responds when polled by the remote system if it answers a call.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>station-address</i></b></dt>
<dd>Specify a hexadecimal value from 01 to FE.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CNNPOLLRTY"></a>
<h3>Connect poll retry (CNNPOLLRTY)</h3>
<p>Specifies, for a switched primary line or a negotiable line, the number of connection polling retries to make before indicating the error and making the station inoperative.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>connect-poll-retry</i></b></dt>
<dd>Specify a value from 0 through 64 for the number of retries.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CNNTMR"></a>
<h3>Connect timer (CNNTMR)</h3>
<p>Specifies, for an X.21 circuit switched interface, the amount of time an automatic answer connect request waits for an incoming call to be accepted.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NOMAX</b></dt>
<dd>The system waits indefinitely.
</dd>
</dl>
<dl>
<dt><b><i>connect-timer</i></b></dt>
<dd>Specify a value from 1 to 32767 in 0.1 second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SHORTTMR"></a>
<h3>Short timer (SHORTTMR)</h3>
<p>Specifies, for X.21 circuit switched interface or short hold mode, the short timer used during bursts of retry operations. The system waits between connection attempts for this timeout period.
</p>
<ol>
<li>The SHORTTMR parameter is used only for X.21 circuit-switched or short-hold mode lines.
</li>
<li>The default meets most countries' or regions' requirements relative to call retries and call delays. In the event that the default does not meet your country's or region's requirements, the value must be configured in accordance with the country or region requirement. Before changing this value, ensure that the new value is in accordance with your country's or region's requirements.
<p>If you are not aware of your country's or region's requirement, your IBM representative or IBM-approved remarketer can provide this information.
</p>
</li>
</ol>
<p>This parameter is used to control retries when you are attempting to make a call over an X.21 circuit-switched or short-hold mode network. Call attempts are characterized by bursts of retries. A single burst of retries is controlled by the short timer and short retry value. If all short retries are completed, the system delays for a longer time (the long timer) before attempting another burst of retries. The total number of these bursts of retries is based on the long retry value.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>50</b></dt>
<dd>The system waits five seconds.
</dd>
<dt><b><i>short-timer</i></b></dt>
<dd>Specify a value from 10 to 600 in 0.1 second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.LONGTMR"></a>
<h3>Long timer (LONGTMR)</h3>
<p>Specifies for an X.21 circuit switched interface or short hold mode, the long timer used between bursts of retry operations. After a burst of retry attempts, the system waits for this timeout period before the next attempt.
</p>
<p>This parameter is used to control retries when you are attempting to make a call over an X.21 circuit-switched or short-hold mode network. Call attempts are characterized by &amp;odq.bursts&amp;cdq. of retries. A single burst of retries is controlled by the short timer and short retry value. If all short retries are completed, the system delays for a longer time (the long timer) before attempting another burst of retries. The total number of these bursts of retries is based on the long retry value.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>600</b></dt>
<dd>The system waits 60 seconds.
</dd>
<dt><b><i>long-timer</i></b></dt>
<dd>Specify a value from 100 to 6000 in 0.1 second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SHORTRTY"></a>
<h3>Short retry (SHORTRTY)</h3>
<p>Specifies for an X.21 circuit switched interface or short hold mode, the number of retry attempts that are made during a burst of retries.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>short-retry</i></b></dt>
<dd>Specify a value from 0 to 254 for the number of retries.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.LONGRTY"></a>
<h3>Long retry (LONGRTY)</h3>
<p>Specifies, for an X.21 circuit switched interface or short hold mode, the number of burst retry attempts when processing a connect request.
</p>
<p>This parameter is used to control retries when you are attempting to make a call over an X.21 circuit-switched or short-hold mode network. Call attempts are characterized by &amp;odq.bursts&amp;cdq. of retries. A single burst of retries is controlled by the short timer and short retry value. If all short retries are completed, the system delays for a longer time (the long timer) before attempting another burst of retries. The total number of these bursts of retries is based on the long retry value.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>1</b></dt>
<dd>One retry is attempted.
</dd>
<dt><b><i>long-retry</i></b></dt>
<dd>Specify a value from 0 to 254 for the number of retries.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CPSRTY"></a>
<h3>Call progress signal retry (CPSRTY)</h3>
<p>Specifies which call progress signals are retried for X.21 circuit switched interface or X.21 short hold mode lines. Up to 11 values can be specified; duplicate values are ignored.
</p>
<p>Valid values are: *CPS41, *CPS42, *CPS43, *CPS44, *CPS45, *CPS46, *CPS47, *CPS48, *CPS49, *CPS71, and *CPS72.
</p>
<p>This parameter can be specified only if *SHM or *SWTPP is specified for the <b>Connection type (CNN)</b> parameter and *X21 is specified on the <b>Physical interface (INTERFACE)</b> parameter.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.MAXFRAME"></a>
<h3>Maximum frame size (MAXFRAME)</h3>
<p>Specifies the maximum frame size that can be transmitted and received on this line description.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>frame-size</i></b></dt>
<dd>The standard frame sizes are:
<ul>
<li>265 (All line types)
</li>
<li>521 (All line types)
</li>
<li>1033 (All line types)
</li>
<li>1994 (Token-ring only)
</li>
<li>2057 (SDLC or Token-ring)
</li>
<li>4105 (TDLC or Token-ring)
</li>
<li>4060 (Token-ring only)
</li>
<li>8156 (Token-ring only)
</li>
<li>16393 (Token-ring only)
</li>
</ul>
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.THRESHOLD"></a>
<h3>Error threshold level (THRESHOLD)</h3>
<p>Specifies the temporary error threshold level being monitored by the system. A permanent error is reported only if the errors occurred consecutively and exceeded the retry limit.
</p>
<p>
<b>Note: </b>Specifying the THRESHOLD parameter affects all threshold errors. They cannot be specified individually.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*OFF</b></dt>
<dd>No threshold errors are reported.
</dd>
</dl>
<dl>
<dt><b>*MIN</b></dt>
<dd>The threshold for errors is set to a minimum monitoring level.
</dd>
</dl>
<dl>
<dt><b>*MED</b></dt>
<dd>The threshold for errors is set to a medium monitoring level.
</dd>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>The threshold for errors is set to a maximum monitoring level.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.DUPLEX"></a>
<h3>Duplex (DUPLEX)</h3>
<p>Specifies whether request-to-send (RTS) is permanently turned on (for duplex modems) or turned on only when transmission is required (for half duplex modems).
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*HALF</b></dt>
<dd>Request-to-send (RTS) is turned on only when transmission is required (for half duplex modems). You can choose to run half duplex even if the modem can support duplex communication.
</dd>
<dt><b>*FULL</b></dt>
<dd>Request-to-send (RTS) is permanently set on (for duplex modems).
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.MODULUS"></a>
<h3>Modulus (MODULUS)</h3>
<p>Specifies whether the extended sequence numbers are used.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>8</b></dt>
<dd>Extended sequence numbers are not used (Modulus 8).
</dd>
<dt><b><i>128</i></b></dt>
<dd>Extended sequence numbers are used (Modulus 128).
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.MAXOUT"></a>
<h3>Maximum outstanding frames (MAXOUT)</h3>
<p>Specifies the maximum number of frames that can be sent to a remote system before the remote system must respond back. For modulus 8, the maximum number of frames must be 1 to 7. For modulus 128, the maximum number of frames must be 8 to 28.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>maximum-outstanding-frames</i></b></dt>
<dd>Specify a value from 1 to 28 for the number of outstanding frames.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.INACTTMR"></a>
<h3>Inactivity timer (INACTTMR)</h3>
<p>Specifies, for a secondary or negotiable line, the time (in tenths of a second) the system waits for a valid frame to flow before reporting the error and disconnecting the line. This timer is started at connection time and restarted when any frame is sent, and then reset when a frame with a valid frame check sequence is received.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>300</b></dt>
<dd>The system waits 30 seconds (300 tenths of a second) for a valid frame.
</dd>
<dt><b><i>inactivity-timer</i></b></dt>
<dd>Specify a value from 150 to 4200 in 0.1 second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.POLLRSPDLY"></a>
<h3>Poll response delay (POLLRSPDLY)</h3>
<p>Specifies, for a secondary or negotiable line, the minimum time the system must wait before it responds to a data poll if there is no frame to transmit.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>poll-response-delay</i></b></dt>
<dd>Specify a value from 1 to 2048 in 0.0001 second intervals, or 0 to indicate no delay.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.NPRDRCVTMR"></a>
<h3>Nonproductive receive timer (NPRDRCVTMR)</h3>
<p>Specifies, for a primary or negotiable line, the time the system waits for either a final frame or an idle signal while the secondary station is continuously sending. If this timer expires, the nonproductive receive condition is reported.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>nonproductive-receive-timer</i></b></dt>
<dd>Specify a value from 160 to 4200 in 0.1 second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.IDLTMR"></a>
<h3>Idle timer (IDLTMR)</h3>
<p>Specifies, for a primary or negotiable line, the time (in 0.1 second intervals) that the system waits before sampling the line for an idle signal. If an idle signal is detected, error recovery procedures are started.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>idle-timer</i></b></dt>
<dd>Specify a value from 5 to 300 in 0.1 second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CNNPOLLTMR"></a>
<h3>Connect poll timer (CNNPOLLTMR)</h3>
<p>Specifies, for a primary or negotiable line, the time the system waits for the response to a connect poll before resending the poll.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>connect-poll-timer</i></b></dt>
<dd>Specify a value from 2 to 300 in 0.1 second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.POLLPAUSE"></a>
<h3>Poll cycle pause (POLLPAUSE)</h3>
<p>Specifies, for a primary or negotiable line, the time the system pauses after the last remote system in the poll list is polled.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>poll-cycle-pause</i></b></dt>
<dd>Specify a value from 1 to 2048 in 0.0001 second intervals, or 0 to indicate no pause.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.FRAMERTY"></a>
<h3>Frame retry (FRAMERTY)</h3>
<p>Specifies, for a primary, negotiable, or X.25 line, the number of retries for an unanswered command frame or unacknowledged information frame before indicating the error.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>frame-retry</i></b></dt>
<dd>Specify a value from 0 to 64 for the number of retries.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.FAIRPLLTMR"></a>
<h3>Fair polling timer (FAIRPLLTMR)</h3>
<p>Specifies, for a multipoint line, the number of seconds the system waits before resuming polling of stations without pending data transfer requests.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>fair-poll-timer</i></b></dt>
<dd>Specify a value from 5 to 60 in one second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.DSRDRPTMR"></a>
<h3>Data Set Ready drop timer (DSRDRPTMR)</h3>
<p>Specifies the amount of time that the system waits for the modem to exit the Data Set Ready (DSR) state before signaling an error.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>drop-timer</i></b></dt>
<dd>Specify a value ranging from 3 through 60 seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.AUTOANSTYP"></a>
<h3>Autoanswer type (AUTOANSTYP)</h3>
<p>Specifies the method that the system uses to answer incoming calls.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*DTR</b></dt>
<dd>The system enters the Data Terminal Ready state, signals the modem to answer calls, and waits for the modem to enter the Data Set Ready (DSR) state.
</dd>
<dt><b>*CDSTL</b></dt>
<dd>The system enters the Connect Data Set to Line (CDSTL) state after monitoring the Ring Indicator to signal the modem to answer the call.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CTSTMR"></a>
<h3>Clear To Send timer (CTSTMR)</h3>
<p>Specifies the amount of time the system waits for the modem to enter or exit the Clear to Send (CTS) state before signaling an error.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>cts-timer</i></b></dt>
<dd>Specify a value ranging from 10 through 60 seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.RMTANSTMR"></a>
<h3>Remote answer timer (RMTANSTMR)</h3>
<p>Specifies the amount of time that system waits for the modem to enter the Data Set Ready (DSR) state after dialing before signaling an error.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>answer-timer</i></b></dt>
<dd>Specify a value ranging from 30 through 120 seconds in 5-second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.LINKSPEED"></a>
<h3>Link speed (LINKSPEED)</h3>
<p>Specifies the link speed in bits per second (bps). This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*INTERFACE (SDLC and X.25 only)</b></dt>
<dd>The link speed is based on the physical interface type: 9600 bps for RS-232/V.24 and X.21 bis/V.24, 48000 bps for V.35 and X.21 bis/V.35, and 64000 bps for X.21 and RS-449V.36.
</dd>
</dl>
<dl>
<dt><b>*MIN</b></dt>
<dd>A link speed of less than 1200 bps is used.
</dd>
</dl>
<dl>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>A link speed greater than 100M bps is used.
</dd>
</dl>
<dl>
<dt><b><i>link-speed</i></b></dt>
<dd>Specify a link speed. The valid link speeds are 1200, 2400, 4800, 7200, 9600, 14400, 19200, 48000, 56000, 64000, 112000, 128000, 168000, 192000, 224000, 256000, 280000, 320000, 336000, 384000, 448000, 499000, 576000, 614000, 691000, 768000, 845000, 922000, 998000, 1075000, 1152000, 1229000, 1382000, 1536000, 1690000, 1843000, 1997000, 4M, 10M and 16M bps.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.COSTCNN"></a>
<h3>Cost/connect time (COSTCNN)</h3>
<p>Specifies the relative cost of being connected on the line. Zero implies a low cost while 255 indicates a high cost. This parameter is valid only if APPN is used on the system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*CNN (SDLC and IDLC only)</b></dt>
<dd>The cost per connection time is based on the connection type: Zero for nonswitched connections and 128 for switched connections.
</dd>
<dt><b><i>cost-per-connect-time</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.COSTBYTE"></a>
<h3>Cost/byte (COSTBYTE)</h3>
<p>Specifies the relative cost per byte for sending and receiving data on the line. Zero implies a low cost while 255 indicates a high cost. This parameter is valid only if APPN is used on the system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*CNN (SDLC and IDLC only)</b></dt>
<dd>The cost per byte is based on the connection type: Zero for nonswitched connections and 128 for switched connections.
</dd>
<dt><b><i>cost-per-byte</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.SECURITY"></a>
<h3>Security for line (SECURITY)</h3>
<p>Specifies the security level of the physical line. This parameter is valid only if APPN is used on the system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*NONSECURE</b></dt>
<dd>There is no security on the line.
</dd>
<dt><b>*PKTSWTNET</b></dt>
<dd>A packet switched network is used. Data does not always follow the same path through the network.
</dd>
<dt><b>*UNDRGRDCBL</b></dt>
<dd>An underground cable is used.
</dd>
<dt><b>*SECURECND</b></dt>
<dd>A secure, but unguarded, conduit is used.
</dd>
<dt><b>*GUARDCND</b></dt>
<dd>A guarded conduit, protected against physical tapping, is used.
</dd>
<dt><b>*ENCRYPTED</b></dt>
<dd>Data flowing on the line is encrypted.
</dd>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>A guarded conduit, protected against physical and radiation tapping is used.
</dd>
</dl>
<dl>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.PRPDLY"></a>
<h3>Propagation delay (PRPDLY)</h3>
<p>Specifies the level of propagation delay on the line. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system. The order of the values from shortest to longest delay is *MIN, *LAN, *TELEPHONE, *PKTSWTNET, and *SATELLITE.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*MIN</b></dt>
<dd>The minimum propagation delay is used.
</dd>
</dl>
<dl>
<dt><b>*LAN</b></dt>
<dd>Propagation delay using a local area network.
</dd>
<dt><b>*TELEPHONE</b></dt>
<dd>Propagation delay using telephone lines.
</dd>
<dt><b>*PKTSWTNET</b></dt>
<dd>Propagation delay using a packet switched network.
</dd>
<dt><b>*SATELLITE</b></dt>
<dd>Propagation delay using satellite communications.
</dd>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>The maximum propagation delay is used.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.USRDFN1"></a>
<h3>User-defined 1 (USRDFN1)</h3>
<p>This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>user-defined-1</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.USRDFN2"></a>
<h3>User-defined 2 (USRDFN2)</h3>
<p>This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>user-defined-2</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.USRDFN3"></a>
<h3>User-defined 3 (USRDFN3)</h3>
<p>This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>user-defined-3</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.CMNRCYLMT"></a>
<h3>Recovery limits (CMNRCYLMT)</h3>
<p>Specifies the second-level communications recovery limits to be used for this line description.
</p>
<p>The possible <b>count-limit</b> values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*SYSVAL</b></dt>
<dd>The value in the QCMNRCYLMT system value is used.
</dd>
</dl>
<dl>
<dt><b><i>count-limit</i></b></dt>
<dd>Specify the number of recovery attempts to be performed by the system. Valid values range from 0 through 99.
</dd>
</dl>
<p>The possible <b>time-interval</b> values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b><i>time-interval</i></b></dt>
<dd>Specify the number of minutes within which recovery attempts are made. Valid values range from 0 through 120 in 1-minute intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGLINSDLC.TEXT"></a>
<h3>Text 'description' (TEXT)</h3>
<p>Specifies text that briefly describes the line description.
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value does not change.
</dd>
</dl>
<dl>
<dt><b>*BLANK</b></dt>
<dd>Text is not specified.
</dd>
<dt><b><i>character-value</i></b></dt>
<dd>Specify no more than 50 characters of text, enclosed in apostrophes.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div><h3><a name="CHGLINSDLC.COMMAND.EXAMPLES">Examples</a> </h3>
<p>
<pre>
CHGLINSDLC LIND(TUESDAY) RSRCNAME(LIN031)
</pre>
</p>
<p>This command changes the resource name for line description TUESDAY to LIN031.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div><h3><a name="CHGLINSDLC.ERROR.MESSAGES">Error messages</a> </h3>
<p><b><u>*ESCAPE Messages</u></b>
</p>
<dl>
<dt><b>CPF261E</b></dt>
<dd>Line description &amp;1 not changed.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGLINSDLC.Top_Of_Page">Top</a></td></tr>
</table>
</body>
</html>