1232 lines
41 KiB
HTML
1232 lines
41 KiB
HTML
|
|
||
|
<!doctype html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
|
||
|
<html>
|
||
|
<head><META http-equiv="Content-Type" content="text/html; charset=utf-8">
|
||
|
<title>Change Line Desc (Async) (CHGLINASC)</title>
|
||
|
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
|
||
|
</head>
|
||
|
<body bgcolor="white">
|
||
|
<script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
||
|
<a name="CHGLINASC.Top_Of_Page"></a>
|
||
|
<h2>Change Line Desc (Async) (CHGLINASC)</h2>
|
||
|
<table width="100%">
|
||
|
<tr>
|
||
|
<td valign="top" align="left"><b>Where allowed to run: </b>All environments (*ALL)<br>
|
||
|
<b>Threadsafe: </b>No
|
||
|
</td>
|
||
|
<td valign="top" align="right">
|
||
|
<a href="#CHGLINASC.PARAMETERS.TABLE">Parameters</a><br>
|
||
|
<a href="#CHGLINASC.COMMAND.EXAMPLES">Examples</a><br>
|
||
|
<a href="#CHGLINASC.ERROR.MESSAGES">Error messages</a></td>
|
||
|
</tr>
|
||
|
</table>
|
||
|
|
||
|
<div> <a name="CHGLINASC"></a>
|
||
|
<p>The Change Line Description (Async) (CHGLINASC) command changes a line description for an asynchronous line.
|
||
|
</p>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<hr size="2" width="100%">
|
||
|
|
||
|
<div>
|
||
|
<h3><a name="CHGLINASC.PARAMETERS.TABLE">Parameters</a></h3>
|
||
|
<table border="1" cellpadding="4" cellspacing="0">
|
||
|
<!-- col1="10" col2="15" col3="30" col4="10" -->
|
||
|
<tr>
|
||
|
<th bgcolor="aqua" valign="bottom" align="left">Keyword</th>
|
||
|
<th bgcolor="aqua" valign="bottom" align="left">Description</th>
|
||
|
<th bgcolor="aqua" valign="bottom" align="left">Choices</th>
|
||
|
<th bgcolor="aqua" valign="bottom" align="left">Notes</th>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.LIND"><b>LIND</b></a></td>
|
||
|
<td valign="top">Line description</td>
|
||
|
<td valign="top"><i>Name</i></td>
|
||
|
<td valign="top">Required, Key, Positional 1</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.RSRCNAME"><b>RSRCNAME</b></a></td>
|
||
|
<td valign="top">Resource name</td>
|
||
|
<td valign="top"><i>Name</i>, <b><u>*SAME</u></b></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.ONLINE"><b>ONLINE</b></a></td>
|
||
|
<td valign="top">Online at IPL</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.ACTSNBU"><b>ACTSNBU</b></a></td>
|
||
|
<td valign="top">Activate swt network backup</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.VRYWAIT"><b>VRYWAIT</b></a></td>
|
||
|
<td valign="top">Vary on wait</td>
|
||
|
<td valign="top">15-180, <b><u>*SAME</u></b>, *NOWAIT</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.SWTCTLLST"><b>SWTCTLLST</b></a></td>
|
||
|
<td valign="top">Switched controller list</td>
|
||
|
<td valign="top">Single values: <b><u>*SAME</u></b><br>Other values (up to 64 repetitions): <i>Name</i></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.BITSCHAR"><b>BITSCHAR</b></a></td>
|
||
|
<td valign="top">Data bits per character</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, 7, 8</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.PARITY"><b>PARITY</b></a></td>
|
||
|
<td valign="top">Type of parity</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *NONE, *ODD, *EVEN</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.STOPBITS"><b>STOPBITS</b></a></td>
|
||
|
<td valign="top">Stop bits</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, 1, 2</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.DUPLEX"><b>DUPLEX</b></a></td>
|
||
|
<td valign="top">Duplex</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *FULL, *HALF</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.ECHO"><b>ECHO</b></a></td>
|
||
|
<td valign="top">Echo support</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *NONE, *ALL, *CNTL</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.LINESPEED"><b>LINESPEED</b></a></td>
|
||
|
<td valign="top">Line speed</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, 50, 75, 110, 150, 300, 600, 1200, 2400, 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 76800, 115200</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.MODEM"><b>MODEM</b></a></td>
|
||
|
<td valign="top">Modem type supported</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *NORMAL, *V54, *IBMWRAP</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.MODEMRATE"><b>MODEMRATE</b></a></td>
|
||
|
<td valign="top">Modem data rate select</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *FULL, *HALF</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.SWTCNN"><b>SWTCNN</b></a></td>
|
||
|
<td valign="top">Switched connection type</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *BOTH, *ANS, *DIAL</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.AUTOANS"><b>AUTOANS</b></a></td>
|
||
|
<td valign="top">Autoanswer</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.AUTODIAL"><b>AUTODIAL</b></a></td>
|
||
|
<td valign="top">Autodial</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.DIALCMD"><b>DIALCMD</b></a></td>
|
||
|
<td valign="top">Dial command type</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *NONE, *V25BIS, *OTHER</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.SETMDMASC"><b>SETMDMASC</b></a></td>
|
||
|
<td valign="top">Set modem to ASYNC command</td>
|
||
|
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, END, *NONE</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.MDMINZCMD"><b>MDMINZCMD</b></a></td>
|
||
|
<td valign="top">Modem init command string</td>
|
||
|
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *NONE</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.ACRSRCNAME"><b>ACRSRCNAME</b></a></td>
|
||
|
<td valign="top">Autocall resource name</td>
|
||
|
<td valign="top"><i>Name</i>, <b><u>*SAME</u></b></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.CALLNBR"><b>CALLNBR</b></a></td>
|
||
|
<td valign="top">Calling number</td>
|
||
|
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *NONE</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.INACTTMR"><b>INACTTMR</b></a></td>
|
||
|
<td valign="top">Inactivity timer</td>
|
||
|
<td valign="top">150-4200, <b><u>*SAME</u></b>, *NOMAX</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.MAXBUFFER"><b>MAXBUFFER</b></a></td>
|
||
|
<td valign="top">Maximum buffer size</td>
|
||
|
<td valign="top">128-4096, <b><u>*SAME</u></b></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.THRESHOLD"><b>THRESHOLD</b></a></td>
|
||
|
<td valign="top">Error threshold level</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *OFF, *MIN, *MED, *MAX</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.FLOWCNTL"><b>FLOWCNTL</b></a></td>
|
||
|
<td valign="top">Flow control</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *YES, *NO, *HARDWARE</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.XONCHAR"><b>XONCHAR</b></a></td>
|
||
|
<td valign="top">XON character</td>
|
||
|
<td valign="top">01-FF, <b><u>*SAME</u></b></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.XOFFCHAR"><b>XOFFCHAR</b></a></td>
|
||
|
<td valign="top">XOFF character</td>
|
||
|
<td valign="top">01-FF, <b><u>*SAME</u></b></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top" rowspan="3"><a href="#CHGLINASC.EORTBL"><b>EORTBL</b></a></td>
|
||
|
<td valign="top">End-of-Record table</td>
|
||
|
<td valign="top">Single values: <b><u>*SAME</u></b><br>Other values (up to 8 repetitions): <i>Element list</i></td>
|
||
|
<td valign="top" rowspan="3">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top">Element 1: End-of-Record character</td>
|
||
|
<td valign="top">
|
||
|
<b><u>00</u></b>, 01, 02, 03, 04, 05, 06, 07, 08, 09, 0A, 0B, 0C, 0D, 0E, 0F, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 1A, 1B, 1C, 1D, 1E, 1F, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 2A, 2B, 2C, 2D, 2E, 2F, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 3A, 3B, 3C, 3D, 3E, 3F, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 4A, 4B, 4C, 4D, 4E, 4F, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 5A, 5B, 5C, 5D, 5E, 5F, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 6A, 6B, 6C, 6D, 6E, 6F, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 7A, 7B, 7C, 7D, 7E, 7F, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 8A, 8B, 8C, 8D, 8E, 8F, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 9A, 9B, 9C, 9D, 9E, 9F, A0, A1, A2, A3, A4, A5, A6, A7, A8, A9, AA, AB, AC, AD, AE, AF, B0, B1, B2, B3, B4, B5, B6, B7, B8, B9, BA, BB, BC, BD, BE, BF, C0, C1, C2, C3, C4, C5, C6, C7, C8, C9, CA, CB, CC, CD, CE, CF, D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, DA, DB, DC, DD, DE, DF, E0, E1, E2, E3, E4, E5, E6, E7, E8, E9, EA, EB, EC, ED, EE, EF, F0, F1, F2, F3, F4, F5, F6, F7, F8, F9, FA, FB, FC, FD, FE, FF</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top">Element 2: Trailing characters</td>
|
||
|
<td valign="top">
|
||
|
0-4, <b><u>0</u></b></td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.IDLTMR"><b>IDLTMR</b></a></td>
|
||
|
<td valign="top">Idle timer</td>
|
||
|
<td valign="top">0-254, <b><u>*SAME</u></b></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.DSRDRPTMR"><b>DSRDRPTMR</b></a></td>
|
||
|
<td valign="top">Data Set Ready drop timer</td>
|
||
|
<td valign="top">3-60, <b><u>*SAME</u></b></td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.AUTOANSTYP"><b>AUTOANSTYP</b></a></td>
|
||
|
<td valign="top">Autoanswer type</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, *DTR, *CDSTL</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.CTSTMR"><b>CTSTMR</b></a></td>
|
||
|
<td valign="top">Clear To Send timer</td>
|
||
|
<td valign="top">10-120, <b><u>*SAME</u></b>, *NOMAX</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.RMTANSTMR"><b>RMTANSTMR</b></a></td>
|
||
|
<td valign="top">Remote answer timer</td>
|
||
|
<td valign="top"><b><u>*SAME</u></b>, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top" rowspan="3"><a href="#CHGLINASC.CMNRCYLMT"><b>CMNRCYLMT</b></a></td>
|
||
|
<td valign="top">Recovery limits</td>
|
||
|
<td valign="top">Single values: <b><u>*SAME</u></b>, *SYSVAL<br>Other values: <i>Element list</i></td>
|
||
|
<td valign="top" rowspan="3">Optional</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top">Element 1: Count limit</td>
|
||
|
<td valign="top">
|
||
|
0-99</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top">Element 2: Time interval</td>
|
||
|
<td valign="top">
|
||
|
0-120</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td valign="top"><a href="#CHGLINASC.TEXT"><b>TEXT</b></a></td>
|
||
|
<td valign="top">Text 'description'</td>
|
||
|
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *BLANK</td>
|
||
|
<td valign="top">Optional</td>
|
||
|
</tr>
|
||
|
</table>
|
||
|
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
</div>
|
||
|
<div> <a name="CHGLINASC.LIND"></a>
|
||
|
<h3>Line description (LIND)</h3>
|
||
|
<p>Specifies the name of the line description
|
||
|
</p>
|
||
|
<p>This is a required parameter.
|
||
|
</p>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.RSRCNAME"></a>
|
||
|
<h3>Resource names (RSRCNAME)</h3>
|
||
|
<p>Specifies the resource name that identifies the hardware this description represents. Use the WRKHDWRSC command to determine the resource name.
|
||
|
</p>
|
||
|
<p>This is a required parameter.
|
||
|
</p>
|
||
|
<p>You can enter multiple values for this parameter.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.ONLINE"></a>
|
||
|
<h3>Online at IPL (ONLINE)</h3>
|
||
|
<p>Specifies whether this object is automatically varied on at initial program load (IPL).
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*YES</b></dt>
|
||
|
<dd>The line is automatically varied on at initial program load (IPL).
|
||
|
</dd>
|
||
|
<dt><b>*NO</b></dt>
|
||
|
<dd>This line is not automatically varied on at IPL.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.ACTSNBU"></a>
|
||
|
<h3>Activate swt network backup (ACTSNBU)</h3>
|
||
|
<p>Specifies, for modems that support the switched network backup (SNBU) feature and that are not IBM 386x, 586x, or 786x models, whether the SNBU feature is activated or deactivated. The local modem and remote modem must both support the SNBU to activate it. IBM 386x, 586x, and 786x models are activated with a hardware switch only. This feature lets you bypass a broken nonswitched connection (nonswitched line) by establishing a switched connection.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>This value does not change from the value previously specified either on this parameter or on the SNBU parameter of the command creating the line description.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NO</b></dt>
|
||
|
<dd>The SNBU feature is not used.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*YES</b></dt>
|
||
|
<dd>The SNBU feature is activated. You must also specify a value of *YES for the <b>Activate swt network backup (ACTSNBU)</b> parameter for the controller.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.VRYWAIT"></a>
|
||
|
<h3>Vary on wait (VRYWAIT)</h3>
|
||
|
<p>Specifies whether the line is varied on asynchronously or synchronously. For synchronous vary on, this parameter specifies how long the system waits for the vary on to complete.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NOWAIT</b></dt>
|
||
|
<dd>The system does not wait for vary on completion. The line is varied on asynchronously.
|
||
|
</dd>
|
||
|
<dt><b><i>vary-on-wait</i></b></dt>
|
||
|
<dd>Specify the time (in seconds) to wait. Valid values range from 15 through 180. The system waits until the line is varied on, or until the specified time passes, before completing the Vary Configuration (VRYCFG) command.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<p><b>Notes:</b>
|
||
|
</p>
|
||
|
<ol>
|
||
|
<li>When ONLINE(*YES) is used, specifying a wait time in the line description affects system IPL time. In such cases, system IPL time is influenced by the amount of time required to synchronously vary on the line or reach the wait-time value.
|
||
|
</li>
|
||
|
<li>The time required to vary on a line is the time it takes to:
|
||
|
<ul>
|
||
|
<li>Put tasks in place to manage the line
|
||
|
</li>
|
||
|
<li>Activate the communications I/O processor (IOP), including downloading the IOP model-unique Licensed Internal Code
|
||
|
</li>
|
||
|
<li>Establish the communications tasks and processes
|
||
|
</li>
|
||
|
</ul>
|
||
|
</li>
|
||
|
</ol>
|
||
|
<p>Normal vary-on time ranges from 5 through 45 seconds, but can be longer, depending on the system, line protocol, and other factors.
|
||
|
</p>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.SWTCTLLST"></a>
|
||
|
<h3>Switched controller list (SWTCTLLST)</h3>
|
||
|
<p>Specifies the names of up to 64 switched controllers that can establish a connection with this switched line. The controller descriptions must already exist. This parameter is valid only if the line is switched or the nonswitched line has the switched network backup (SNBU) feature.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>switched-controller-list</i></b></dt>
|
||
|
<dd>Specify the switched controller names. Up to 64 switched controllers can be specified.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.BITSCHAR"></a>
|
||
|
<h3>Data bits per character (BITSCHAR)</h3>
|
||
|
<p>Specifies the number of data bits per character (excluding the parity bit if any).
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>8</b></dt>
|
||
|
<dd>8 data bits per character are used.
|
||
|
<p>
|
||
|
<b>Note: </b>8 bits with parity cannot be used with some Input/Output processors.
|
||
|
</p>
|
||
|
</dd>
|
||
|
<dt><b>7</b></dt>
|
||
|
<dd>7 data bits per character are used.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.PARITY"></a>
|
||
|
<h3>Type of parity (PARITY)</h3>
|
||
|
<p>Specifies the type of parity used for error checking (a parity bit is a binary digit inserted in each byte of data to make the arithmetic sum of all the digits, including the parity bit, always odd or always even).
|
||
|
</p>
|
||
|
<p>
|
||
|
<b>Note: </b>The remote system must use the same parity.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NONE</b></dt>
|
||
|
<dd>No parity bit is inserted in the data byte.
|
||
|
</dd>
|
||
|
<dt><b>*ODD</b></dt>
|
||
|
<dd>The arithmetic sum of all the digits, including the parity bit, is odd.
|
||
|
</dd>
|
||
|
<dt><b>*EVEN</b></dt>
|
||
|
<dd>The arithmetic sum of all the digits, including the parity bit, is even.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.STOPBITS"></a>
|
||
|
<h3>Stop bits (STOPBITS)</h3>
|
||
|
<p>Specifies the number of bits added to the end of each character. These bits are used to keep the local and remote ends of the line synchronized.
|
||
|
</p>
|
||
|
<p>
|
||
|
<b>Note: </b>The remote system must use the same number of stop bits as the local system.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>1</b></dt>
|
||
|
<dd>1 stop bit is added to each character.
|
||
|
</dd>
|
||
|
<dt><b>2</b></dt>
|
||
|
<dd>2 stop bits are added to each character.
|
||
|
<p>
|
||
|
<b>Note: </b>At line speeds of 300 bps or lower, 2 stop bits are recommended.
|
||
|
</p>
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.DUPLEX"></a>
|
||
|
<h3>Duplex (DUPLEX)</h3>
|
||
|
<p>Specifies whether request-to-send (RTS) is permanently turned on (for duplex modems) or turned on only when transmission is required (for half duplex modems).
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*HALF</b></dt>
|
||
|
<dd>Request-to-send (RTS) is turned on only when transmission is required (for half duplex modems). You can choose to run half duplex even if the modem can support duplex communication.
|
||
|
</dd>
|
||
|
<dt><b>*FULL</b></dt>
|
||
|
<dd>Request-to-send (RTS) is permanently set on (for duplex modems).
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.ECHO"></a>
|
||
|
<h3>Echo support (ECHO)</h3>
|
||
|
<p>Specifies whether the system sends back (echo) all characters it receives to the remote system, send back all characters except end-of-record characters, or if echo is inhibited.
|
||
|
</p>
|
||
|
<p>
|
||
|
<b>Note: </b>Specify *ALL or *CNTL if this line supports communication with a remote system that requires echo. If you specify *ALL or *CNTL, you must also specify *FULL for the <b>Duplex (DUPLEX)</b> parameter.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NONE</b></dt>
|
||
|
<dd>No characters received are echoed to the remote system.
|
||
|
</dd>
|
||
|
<dt><b>*ALL</b></dt>
|
||
|
<dd>All characters received are echoed to the remote system.
|
||
|
</dd>
|
||
|
<dt><b>*CNTL</b></dt>
|
||
|
<dd>All characters received prior to end-of-record characters are echoed to the remote system.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.LINESPEED"></a>
|
||
|
<h3>Line speed (LINESPEED)</h3>
|
||
|
<p>Specifies the line speed in bits per second (bps).
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>1200</b></dt>
|
||
|
<dd>1200 bps is used.
|
||
|
</dd>
|
||
|
<dt><b><i>line-speed</i></b></dt>
|
||
|
<dd>Specify the line speeds. Valid lines speeds are: 50, 75, 110, 150, 300 600, 1200, 2400 4800, 7200, 9600, 14400, 19200, 28800, 38400, 57600, 76800, or 115200 bits per second.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.MODEM"></a>
|
||
|
<h3>Modem type supported (MODEM)</h3>
|
||
|
<p>Specifies the type of modem supported on the communications line. Refer to the modem manual to determine the appropriate value to select.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NORMAL</b></dt>
|
||
|
<dd>No attempt is made to run a diagnostic test to your modem.
|
||
|
</dd>
|
||
|
<dt><b>*V54</b></dt>
|
||
|
<dd>A certain type of diagnostic test (as defined by the CCITT recommendations) is run to your modem. This system supports CCITT V.54 loop 3, local loop back, and loop 2, which is a remote loop back.
|
||
|
</dd>
|
||
|
<dt><b>*IBMWRAP</b></dt>
|
||
|
<dd>An IBM modem with wrap test capabilities is used on the communications line.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.MODEMRATE"></a>
|
||
|
<h3>Modem data rate select (MODEMRATE)</h3>
|
||
|
<p>Specifies the speed at which the line operates if the modem has the data rate select feature.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*FULL</b></dt>
|
||
|
<dd>The line operates at the full rate of the modem.
|
||
|
</dd>
|
||
|
<dt><b>*HALF</b></dt>
|
||
|
<dd>The line operates at half the full rate of the modem.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.SWTCNN"></a>
|
||
|
<h3>Switched connection type (SWTCNN)</h3>
|
||
|
<p>Specifies whether the switched (Async, BSC, SDLC, or IDLC) line or switched network backup (Async, BSC, or SDLC) line is used for incoming calls, outgoing calls, or both.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*BOTH</b></dt>
|
||
|
<dd>The line is used for both incoming and outgoing calls.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*ANS</b></dt>
|
||
|
<dd>The line is used for incoming calls only.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*DIAL</b></dt>
|
||
|
<dd>The line is used for outgoing calls only.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.AUTOANS"></a>
|
||
|
<h3>Autoanswer (AUTOANS)</h3>
|
||
|
<p>Specifies, for switched or switched network backup lines (Async, BSC, SDLC, or X.25 line), whether the system automatically answers a call from a remote system to establish the connection, or whether the system operator manually answers the call and places the modem in data mode.
|
||
|
</p>
|
||
|
<p>
|
||
|
<b>Note: </b>*YES is a valid option only if the modem has the automatic answer feature.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*YES</b></dt>
|
||
|
<dd>The incoming call is automatically answered by the automatic answer feature.
|
||
|
</dd>
|
||
|
<dt><b>*NO</b></dt>
|
||
|
<dd>The incoming call must be manually answered.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.AUTODIAL"></a>
|
||
|
<h3>Autodial (AUTODIAL)</h3>
|
||
|
<p>Specifies, for switched lines, whether the system automatically calls a remote system to establish a connection or if the system operator must manually place the call.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NO</b></dt>
|
||
|
<dd>The line connection is made by manually dialing the X.25 network.
|
||
|
</dd>
|
||
|
<dt><b>*YES</b></dt>
|
||
|
<dd>The line connection is made by the system automatically dialing the X.25 network.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.DIALCMD"></a>
|
||
|
<h3>Dial command type (DIALCMD)</h3>
|
||
|
<p>Specifies the type of dial command used to establish a switched connection with a remote system.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NONE</b></dt>
|
||
|
<dd>No dial command is used. (An automatic call unit is used to establish the connection.)
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*V25BIS</b></dt>
|
||
|
<dd>V.25 bis is a recommendation which allows the use of one physical interface for call establishment and data transmission. It is referred to as a serial automatic call interface because the digits are presented serially on the link from the system to the modem.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*OTHER</b></dt>
|
||
|
<dd>The IBM command set is one example of another command type that is used by asynchronous protocols. The dial digits and all other call-related data must be placed directly into the data stream by the application program.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.SETMDMASC"></a>
|
||
|
<h3>Set modem to ASYNC command (SETMDMASC)</h3>
|
||
|
<p>Specifies the V25BIS command string to send to the modem to set the modem to ASYNC mode.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NONE</b></dt>
|
||
|
<dd>No V25BIS command string is sent to the modem.
|
||
|
</dd>
|
||
|
<dt><b>END</b></dt>
|
||
|
<dd>The END command string is generally used as the command to set most modems to ASYNC mode. For cases that do not use the END command string, you should enter the command string appropriate for that modem to set it to ASYNC mode.
|
||
|
</dd>
|
||
|
<dt><b><i>command-string</i></b></dt>
|
||
|
<dd>Specify up to 40 characters that represent the command issued. Valid characters are upper case characters A through Z, lower case characters a through z, numbers 0 through 9, and the following special characters:
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>.</b></dt>
|
||
|
<dd>Period
|
||
|
</dd>
|
||
|
<dt><b><</b></dt>
|
||
|
<dd>Less than sign
|
||
|
</dd>
|
||
|
<dt><b>(</b></dt>
|
||
|
<dd>Left parenthesis
|
||
|
</dd>
|
||
|
<dt><b>+</b></dt>
|
||
|
<dd>Plus sign
|
||
|
</dd>
|
||
|
<dt><b>&</b></dt>
|
||
|
<dd>Ampersand
|
||
|
</dd>
|
||
|
<dt><b>*</b></dt>
|
||
|
<dd>Asterisk
|
||
|
</dd>
|
||
|
<dt><b>)</b></dt>
|
||
|
<dd>Right parenthesis
|
||
|
</dd>
|
||
|
<dt><b>;</b></dt>
|
||
|
<dd>Semicolon
|
||
|
</dd>
|
||
|
<dt><b>-</b></dt>
|
||
|
<dd>Minus sign
|
||
|
</dd>
|
||
|
<dt><b>/</b></dt>
|
||
|
<dd>Slash
|
||
|
</dd>
|
||
|
<dt><b>,</b></dt>
|
||
|
<dd>Comma
|
||
|
</dd>
|
||
|
<dt><b>_</b></dt>
|
||
|
<dd>Underline
|
||
|
</dd>
|
||
|
<dt><b>></b></dt>
|
||
|
<dd>Greater than sign
|
||
|
</dd>
|
||
|
<dt><b>?</b></dt>
|
||
|
<dd>Question mark
|
||
|
</dd>
|
||
|
<dt><b>:</b></dt>
|
||
|
<dd>Colon
|
||
|
</dd>
|
||
|
<dt><b>=</b></dt>
|
||
|
<dd>Equal sign
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.MDMINZCMD"></a>
|
||
|
<h3>Modem init command string (MDMINZCMD)</h3>
|
||
|
<p>Specifies the modem initialization command string sent to set the modem.
|
||
|
</p>
|
||
|
<p>
|
||
|
<b>Note: </b>Valid only when INTERFACE(*INTMODEM) or INFTRFTYPE(*SYNCMODEM) is specified.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NONE</b></dt>
|
||
|
<dd>No command string is sent to the modem.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>command-string</i></b></dt>
|
||
|
<dd>Specifies up to 60 characters that represent the command string sent to the modem. Valid characters are upper case A thru Z, lower case a thru z, numbers 0 thru 9, and special characters:
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<p>
|
||
|
<pre>
|
||
|
Period
|
||
|
Less than sign
|
||
|
Left parenthesis
|
||
|
Plus sign
|
||
|
Ampersand
|
||
|
Asterisk
|
||
|
Right parenthesis
|
||
|
Semicolon
|
||
|
Minus sign
|
||
|
Slash
|
||
|
Comma
|
||
|
Underline
|
||
|
Greater than sign
|
||
|
Question mark
|
||
|
Colon
|
||
|
Equal sign
|
||
|
Spaces
|
||
|
Number sign
|
||
|
Double quote
|
||
|
Exclamation point
|
||
|
At sign
|
||
|
Hat symbol
|
||
|
Percent
|
||
|
Left square bracket
|
||
|
Right square bracket
|
||
|
Back slash
|
||
|
</pre>
|
||
|
</p>
|
||
|
<p>
|
||
|
<b>Note: </b>The modem initialization string must begin with the two characters 'AT'.
|
||
|
</p>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.ACRSRCNAME"></a>
|
||
|
<h3>Autocall resource name (ACRSRCNAME)</h3>
|
||
|
<p>Specifies the automatic call resource name that describes the automatic call unit port that is used to establish a connection with a remote system. Use the Work with Hardware Resources (WRKHDWRSC) command to determine the resource name.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.CALLNBR"></a>
|
||
|
<h3>Calling number (CALLNBR)</h3>
|
||
|
<p>Specifies the local telephone number of the line that is used for the V.25 bis Call Request with Identification (CRI) dial command. When V.25 bis CRI dialing is used, the system takes the called (connection) number (CNNNBR parameter ), adds a separator character (;), and puts the calling number at the end. The default, *NONE, indicates that Call Request Normal (CRN) is used.
|
||
|
</p>
|
||
|
<p>Specify the calling number only when the modem and network support the CRI dial command.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NONE</b></dt>
|
||
|
<dd>Call Request Normal (CRN) is used. CRN dialing sends only the connection number to the V.25 bis modem.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>calling-number</i></b></dt>
|
||
|
<dd>Specify the local telephone number if V.25 bis CRI dialing is required. The number can be up to 32 characters in length. See your modem documentation to determine the values allowed by the modem.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<p>
|
||
|
<b>Note: </b>Specify the calling number only if both the modem and network support the V.25 bis CRI dial command.
|
||
|
</p>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.INACTTMR"></a>
|
||
|
<h3>Inactivity timer (INACTTMR)</h3>
|
||
|
<p>Specifies the time (in tenths of a second) the system waits for activity on a switched line before disconnecting the line.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NOMAX</b></dt>
|
||
|
<dd>The system waits indefinitely for activity.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>inactivity-timer</i></b></dt>
|
||
|
<dd>Specify a value from 150 to 4200 units. Each unit represents 0.1 second, which provides a time range of 0.3 to 9.9 seconds.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.MAXBUFFER"></a>
|
||
|
<h3>Maximum buffer size (MAXBUFFER)</h3>
|
||
|
<p>Specifies the maximum size of inbound and outbound data buffers.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.THRESHOLD"></a>
|
||
|
<h3>Error threshold level (THRESHOLD)</h3>
|
||
|
<p>Specifies the temporary error threshold level being monitored by the system. A permanent error is reported only if the errors occurred consecutively and exceeded the retry limit.
|
||
|
</p>
|
||
|
<p>
|
||
|
<b>Note: </b>Specifying the THRESHOLD parameter affects all threshold errors. They cannot be specified individually.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*OFF</b></dt>
|
||
|
<dd>No threshold errors are reported.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*MIN</b></dt>
|
||
|
<dd>The threshold for errors is set to a minimum monitoring level.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*MED</b></dt>
|
||
|
<dd>The threshold for errors is set to a medium monitoring level.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*MAX</b></dt>
|
||
|
<dd>The threshold for errors is set to a maximum monitoring level.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.FLOWCNTL"></a>
|
||
|
<h3>Flow control (FLOWCNTL)</h3>
|
||
|
<p>Specifies whether the hardware controls the data flow.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NO</b></dt>
|
||
|
<dd>Prevents the hardware from generating or recognizing flow control characters, and prevents the use of Request to Send (RTS) and Clear to Send (CTS) flow control signals.
|
||
|
</dd>
|
||
|
<dt><b>*YES</b></dt>
|
||
|
<dd>The system uses the flow control capabilities of the asynchronous protocol. If *YES is specified, the hardware recognizes flow control characters. This means that upon receipt of an XOFF character, the hardware stops transmission until an XON character is received. It also means that the hardware sends an XOFF character to the remote location when it is incapable of receiving characters. When the hardware is again able to receive characters, it sends an XON character to the remote system.
|
||
|
</dd>
|
||
|
<dt><b>*HARDWARE</b></dt>
|
||
|
<dd>If this option is specified, the hardware signals the modem to stop sending data by dropping RTS signals when it is not capabl of receiving characters. When the hardware is able to receive characters again, it raises the RTS signal to the modem. Also, the hardware monitor the CTS and RTS signal from the modem and stops sending data when it is turned off.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<p><b>NOTES:</b>
|
||
|
</p>
|
||
|
<ol>
|
||
|
<li>If *YES or *HARDWARE is specified, DUPLEX(*FULL) must be specified.
|
||
|
</li>
|
||
|
<li>Hardware flow control is performed using the Request To Send (RTS) and Clear To Send (CTS) flow control signals.
|
||
|
</li>
|
||
|
</ol>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.XONCHAR"></a>
|
||
|
<h3>XON character (XONCHAR)</h3>
|
||
|
<p>Specifies the hexadecimal value of the flow control character XON. If the system received an XOFF character while sending data, it automatically stops sending, and it starts sending data again only after receiving an XON character.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>XON-character</i></b></dt>
|
||
|
<dd>The XON-character can be any value from hexadecimal 01 through FF; however, you must specify a different character than the XOFF character and one that does not appear in your normal data stream, such as hexadecimal 20 (ASCII blank).
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.XOFFCHAR"></a>
|
||
|
<h3>XOFF character (XOFFCHAR)</h3>
|
||
|
<p>Specifies the hexadecimal value of the flow control character XOFF. If the system receives an XOFF character while sending data, it automatically stops sending, and starts sending data again only after receiving an XON character.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>XOFF-character</i></b></dt>
|
||
|
<dd>Specify the hexadecimal XOFF character. The XOFF-character can be any value between hexadecimal 01 and FF; however, you must specify a different character than the XON character and one that does not appear in your normal data stream, such as hexadecimal 20 (ASCII blank).
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.EORTBL"></a>
|
||
|
<h3>End-of-Record table (EORTBL)</h3>
|
||
|
<p>Specifies the table which allows the hardware to recognize logical records when receiving data. You can define a line feed (LF) as an end-of-record (EOR) character in the data stream, and have the hardware return the data when the LF character is detected in the data stream.
|
||
|
</p>
|
||
|
<p>The EOR table is specified as a set of paired elements, in which the first element of a pair is the EOR character and the second element specifies the number of characters that follow the EOR character. Up to 8 entries can be specified. A value of 00 indicates that no end-of-record character is defined.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>EOR-character</i></b></dt>
|
||
|
<dd>Specify the end-of-record character(s). Valid end-of-record characters are in the range hexadecimal 01 through 7F (if 7 bits-per-character) or 01 through FF (if 8 bits-per-character). End-of-record characters are specified as they appear on the line after any translation by the Asynchronous communications support.
|
||
|
</dd>
|
||
|
<dt><b><i>trailing-characters</i></b></dt>
|
||
|
<dd>Specify the number of additional characters received after the end-of-record character is detected. The number of trailing characters is 0 through 4.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.IDLTMR"></a>
|
||
|
<h3>Idle timer (IDLTMR)</h3>
|
||
|
<p>Specifies the time (in 0.5 second intervals) that the system waits between characters before the adapter forwards the receive buffer to the system.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>idle-timer</i></b></dt>
|
||
|
<dd>Specify a value from 1 to 254 in 0.5 second intervals, or specify 0 which represents no timer.
|
||
|
<p>
|
||
|
<b>Note: </b>Idle timer is also referred to as inter-character timer.
|
||
|
</p>
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.DSRDRPTMR"></a>
|
||
|
<h3>Data Set Ready drop timer (DSRDRPTMR)</h3>
|
||
|
<p>Specifies the amount of time that the system waits for the modem to exit the Data Set Ready (DSR) state before signaling an error.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>drop-timer</i></b></dt>
|
||
|
<dd>Specify a value ranging from 3 through 60 seconds.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.AUTOANSTYP"></a>
|
||
|
<h3>Autoanswer type (AUTOANSTYP)</h3>
|
||
|
<p>Specifies the method that the system uses to answer incoming calls.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*DTR</b></dt>
|
||
|
<dd>The system enters the Data Terminal Ready state, signals the modem to answer calls, and waits for the modem to enter the Data Set Ready (DSR) state.
|
||
|
</dd>
|
||
|
<dt><b>*CDSTL</b></dt>
|
||
|
<dd>The system enters the Connect Data Set to Line (CDSTL) state after monitoring the Ring Indicator to signal the modem to answer the call.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.CTSTMR"></a>
|
||
|
<h3>Clear To Send timer (CTSTMR)</h3>
|
||
|
<p>Specifies the amount of time the system waits for the modem to enter or exit the Clear to Send (CTS) state before signaling an error.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*NOMAX</b></dt>
|
||
|
<dd>The system waits indefinitely.
|
||
|
</dd>
|
||
|
<dt><b><i>cts-timer</i></b></dt>
|
||
|
<dd>Specify a value ranging from 10 through 120 seconds.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.RMTANSTMR"></a>
|
||
|
<h3>Remote answer timer (RMTANSTMR)</h3>
|
||
|
<p>Specifies the amount of time that system waits for the modem to enter the Data Set Ready (DSR) state after dialing before signaling an error.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>answer-timer</i></b></dt>
|
||
|
<dd>Specify a value ranging from 30 through 120 seconds in 5-second intervals.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.CMNRCYLMT"></a>
|
||
|
<h3>Recovery limits (CMNRCYLMT)</h3>
|
||
|
<p>Specifies the second-level communications recovery limits to be used for this line description.
|
||
|
</p>
|
||
|
<p>The possible <b>count-limit</b> values are:
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*SYSVAL</b></dt>
|
||
|
<dd>The value in the QCMNRCYLMT system value is used.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>count-limit</i></b></dt>
|
||
|
<dd>Specify the number of recovery attempts to be performed by the system. Valid values range from 0 through 99.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<p>The possible <b>time-interval</b> values are:
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b><i>time-interval</i></b></dt>
|
||
|
<dd>Specify the number of minutes within which recovery attempts are made. Valid values range from 0 through 120 in 1-minute intervals.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<div> <a name="CHGLINASC.TEXT"></a>
|
||
|
<h3>Text 'description' (TEXT)</h3>
|
||
|
<p>Specifies text that briefly describes the line description.
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b><u>*SAME</u></b></dt>
|
||
|
<dd>The value does not change.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
<dl>
|
||
|
<dt><b>*BLANK</b></dt>
|
||
|
<dd>Text is not specified.
|
||
|
</dd>
|
||
|
<dt><b><i>character-value</i></b></dt>
|
||
|
<dd>Specify no more than 50 characters of text, enclosed in apostrophes.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<hr size="2" width="100%">
|
||
|
<div><h3><a name="CHGLINASC.COMMAND.EXAMPLES">Examples</a> </h3>
|
||
|
<p>
|
||
|
<pre>
|
||
|
CHGLINASC LIND(CHICAGO) LINESPEED(4800)
|
||
|
</pre>
|
||
|
</p>
|
||
|
<p>This command changes the line speed for line description CHICAGO to 4800 bits per second.
|
||
|
</p>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
<hr size="2" width="100%">
|
||
|
<div><h3><a name="CHGLINASC.ERROR.MESSAGES">Error messages</a> </h3>
|
||
|
<p><b><u>*ESCAPE Messages</u></b>
|
||
|
</p>
|
||
|
<dl>
|
||
|
<dt><b>CPF261E</b></dt>
|
||
|
<dd>Line description &1 not changed.
|
||
|
</dd>
|
||
|
</dl>
|
||
|
</div>
|
||
|
<table width="100%">
|
||
|
<tr><td align="right"><a href="#CHGLINASC.Top_Of_Page">Top</a></td></tr>
|
||
|
</table>
|
||
|
</body>
|
||
|
</html>
|