ibm-information-center/dist/eclipse/plugins/i5OS.ic.apis_5.4.0.1/qwtrtvpx.htm

411 lines
12 KiB
HTML
Raw Normal View History

2024-04-02 14:02:31 +00:00
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8">
<meta name="Copyright" content="Copyright (c) 2006 by IBM Corporation">
<title>Retrieve Profile Exit Programs (QWTRTVPX) API</title>
<!-- Begin Header Records ========================================= -->
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<!-- WM SCRIPT A converted by B2H R4.1 (346) (CMS) by V2KEA304 -->
<!-- at RCHVMW2 on 17 Feb 1999 at 11:05:09 -->
<!-- Change History: -->
<!-- YYMMDD USERID Change description -->
<!-- File cleanup completed Nov 2001 by v2cdijab -->
<!-- End Header Records -->
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
</head>
<body>
<a name="Top_Of_Page"></a>
<!-- Java sync-link -->
<script type="text/javascript" language="Javascript" src="../rzahg/synch.js">
</script>
<h2>Retrieve Profile Exit Programs (QWTRTVPX) API</h2>
<div class="box" style="width: 80%;">
<br>
&nbsp;&nbsp;Required Parameter Group:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%">1</td>
<td align="left" valign="top" width="50%">Receiver variable</td>
<td align="left" valign="top" width="20%">Output</td>
<td align="left" valign="top" width="20%">Char(*)</td>
</tr>
<tr>
<td align="center" valign="top">2</td>
<td align="left" valign="top">Length of receiver variable</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">3</td>
<td align="left" valign="top">Format name</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Char(8)</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="left" valign="top">User ID</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Char(10)</td>
</tr>
<tr>
<td align="center" valign="top">5</td>
<td align="left" valign="top">Error code</td>
<td align="left" valign="top">I/O</td>
<td align="left" valign="top">Char(*)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Default Public Authority: *EXCLUDE<br>
<!-- iddvc RMBR -->
<br>
&nbsp;&nbsp;Threadsafe: No<br>
<!-- iddvc RMBR -->
<br>
</div>
<p>The Retrieve Profile Exit Programs (QWTRTVPX) API retrieves the profile exit
flags, based on the format, that have been designated to be called for the
specified user ID. The QWTRTVPX API then places that information into a single
variable in the calling program. The amount of information placed in the
variable depends on the size of the variable.</p>
<br>
<h3>Authorities and Locks</h3>
<p>None.</p>
<h3>Required Parameter Group</h3>
<dl>
<dt><strong>Receiver variable</strong></dt>
<dd>OUTPUT CHAR(*)
<p>The receiver variable that receives the information requested. You can
specify the size of the area to be smaller than the format requested as long as
you specify the length parameter correctly. As a result, the API returns only
the data that the area can hold.</p>
</dd>
<dt><strong>Length of receiver variable</strong></dt>
<dd>INPUT; BINARY(4)
<p>The length of the receiver variable provided. The length of receiver
variable parameter may be specified up to the size of the receiver variable
specified in the user program. If the length of receiver variable parameter
specified is larger than the allocated size of the receiver variable specified
in the user program, the results are not predictable. The minimum length is 8
bytes.</p>
</dd>
<dt><strong>Format name</strong></dt>
<dd>INPUT; CHAR(8)
<p>The format of the profile exit program information to be returned. You can
use this format:</p>
<table cellpadding="5">
<!-- cols="15 85" -->
<tr>
<td align="left" valign="top"><em>ATTN0100</em></td>
<td align="left" valign="top">Preattention information. For details, see <a
href="#HDRATTN100">ATTN0100 Format</a>.</td>
</tr>
<tr>
<td align="left" valign="top"><em>SREQ0100</em></td>
<td align="left" valign="top">Presystem request information. For details, see
<a href="#HDRSREQ100">SREQ0100 Format</a>.</td>
</tr>
</table>
<br>
</dd>
<dt><strong>User ID</strong></dt>
<dd>INPUT; CHAR(10)
<p>The user ID being retrieved. Valid values are as follows:</p>
<table cellpadding="5">
<!-- cols="15 85" -->
<tr>
<td align="left" valign="top"><em>*CURRENT</em></td>
<td align="left" valign="top">The user ID of the job that is currently
running.</td>
</tr>
<tr>
<td align="left" valign="top"><em>User ID name</em></td>
<td align="left" valign="top">The 10-character name that is entered.</td>
</tr>
</table>
<br>
</dd>
<dt><strong>Error code</strong></dt>
<dd>I/O; CHAR(*)
<p>The structure in which to return error information. For the format of the
structure, see <a href="../apiref/error.htm#hdrerrcod">Error Code Parameter</a>.</p>
</dd>
</dl>
<br>
<h3><a name="HDRATTN100">ATTN0100 Format</a></h3>
<p>The following table describes the information that is returned in the
receiver variable for the ATTN0100 format. For detailed descriptions of the
fields, see <a href="#HDRATTNDDE">Field Descriptions</a>.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">BINARY(4)</td>
<td align="left" valign="top" width="60%">Entries returned</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="center" valign="top">4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entries available</td>
</tr>
<tr>
<td align="center" valign="top">&nbsp;</td>
<td align="center" valign="top">&nbsp;</td>
<td align="left" valign="top">ARRAY (*) of BINARY(4)</td>
<td align="left" valign="top">Array of entries</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRATTNDDE">Field Descriptions</a></h3>
<p><strong>Array of entries</strong> An array of entries where the first entry
corresponds to exit program number one for the exit point QIBM_QWT_PREATTNPGMS
and format ATTN0100 in the registration facility. The second entry in the array
corresponds to exit program number 2 and so on. The possible returned values
are as follows:</p>
<table cellpadding="5">
<!-- cols="5 95" -->
<tr>
<td align="left" valign="top"><em>0</em></td>
<td align="left" valign="top">No, do not call this exit program.</td>
</tr>
<tr>
<td align="left" valign="top"><em>1</em></td>
<td align="left" valign="top">Yes, call this exit program.</td>
</tr>
</table>
<p><strong>Entries available</strong> The number of possible entries being
returned. All available data is returned if enough space is provided.</p>
<p><strong>Entries returned</strong> The actual number of entries that is being
returned. If the data is truncated because the receiver variable is not large
enough to hold all of the data available, this value is less than the entries
available.</p>
<br>
<h3><a name="HDRSREQ100">SREQ0100 Format</a></h3>
<p>The following table describes the information that is returned in the
receiver variable for the SREQ0100 format. For detailed descriptions of the
fields, see <a href="#HDRSREQDDE">Field Descriptions</a>.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">BINARY(4)</td>
<td align="left" valign="top" width="60%">Entries returned</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="center" valign="top">4</td>
<td align="LEFT" valign="TOP" width="1%">BINARY(4)</td>
<td align="LEFT" valign="TOP" width="98%">Entries available</td>
</tr>
<tr>
<td align="center" valign="top">&nbsp;</td>
<td align="center" valign="top">&nbsp;</td>
<td align="left" valign="top">ARRAY (*) of BINARY(4)</td>
<td align="left" valign="top">Array of entries</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRSREQDDE">Field Descriptions</a></h3>
<p><strong>Array of entries</strong> An array of entries where the first entry
corresponds to exit program number one for the exit point QIBM_QWT_SYSREQPGMS
and format SREQ0100 in the registration facility. The second entry in the array
corresponds to exit program number 2 and so on. The possible returned values
are as follows:</p>
<table cellpadding="5">
<!-- cols="5 95" -->
<tr>
<td align="left" valign="top"><em>0</em></td>
<td align="left" valign="top">No, do not call this exit program.</td>
</tr>
<tr>
<td align="left" valign="top"><em>1</em></td>
<td align="left" valign="top">Yes, call this exit program.</td>
</tr>
</table>
<p><strong>Entries available</strong> The number of possible entries being
returned. All available data is returned if enough space is provided.</p>
<p><strong>Entries returned</strong> The actual number of entries that is being
returned. If the data is truncated because the receiver variable is not large
enough to hold all of the data available, this value is less than the entries
available.</p>
<br>
<h3>Error Messages</h3>
<table width="100%" cellpadding="5">
<!-- cols="15 85" -->
<tr>
<th align="left" valign="top">Message ID</th>
<th align="left" valign="top">Error Message Text</th>
</tr>
<tr>
<td align="left" valign="top" width="15%">CPF2204 E</td>
<td align="left" valign="top" width="85%">User profile &amp;1 not found.</td>
</tr>
<tr>
<td align="left" valign="top">CPF2213 E</td>
<td align="left" valign="top">Not able to allocate user profile &amp;1.</td>
</tr>
<tr>
<td align="left" valign="top">CPF2217 E</td>
<td align="left" valign="top">Not authorized to user profile &amp;1.</td>
</tr>
<tr>
<td align="left" valign="top">CPF24B4 E</td>
<td align="left" valign="top">Severe error while addressing parameter
list.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3CF1 E</td>
<td align="left" valign="top">Error code parameter not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3CF2 E</td>
<td align="left" valign="top">Error(s) occurred during running of &amp;1
API.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C21 E</td>
<td align="left" valign="top">Format name &amp;1 is not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C24 E</td>
<td align="left" valign="top">Length of the receiver variable is not
valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C90 E</td>
<td align="left" valign="top">Literal value cannot be changed.</td>
</tr>
<tr>
<td align="left" valign="top">CPF9872 E</td>
<td align="left" valign="top">Program or service program &amp;1 in library
&amp;2 ended. Reason code &amp;3.</td>
</tr>
</table>
<br>
<hr>
API introduced: V3R6
<hr>
<center>
<table cellpadding="2" cellspacing="2">
<tr align="center">
<td valign="middle" align="center"><a href="#Top">Top</a> | <a href="wm1.htm">
Work Management APIs</a> | <a href="aplist.htm">APIs by category</a></td>
</tr>
</table>
</center>
</body>