<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8">
<meta name="Copyright" content="Copyright (c) 2006 by IBM Corporation">
<title>Query Line Description (QOLQLIND) API</title>
<!-- Begin Header Records ========================================== -->
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<!-- NETMG2 SCRIPT A converted by B2H R4.1 (346) (CMS) by HOLTJM at -->
<!-- RCHVMW2 on 29 Jan 1999 at 10:01:37 -->
<!-- This file has undergone html cleanup June 2002 by JET -->
<!-- Change History: -->
<!-- YYMMDD USERID Change description -->
<!--File Edited November 2001 -->
<!--End Header Records -->
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
</head>
<body>
<a name="Top_Of_Page"></a>
<!-- Java sync-link -->
<script language="Javascript" src="../rzahg/synch.js" type="text/javascript">
</script>
<h2>Query Line Description (QOLQLIND) API</h2>
<div class="box" style="width: 60%;">
&nbsp;&nbsp;Required Parameter Group:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%">1</td>
<td align="left" valign="top" width="50%">Return code</td>
<td align="left" valign="top" width="20%">Output</td>
<td align="left" valign="top" width="20%">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">2</td>
<td align="left" valign="top">Reason code</td>
<td align="left" valign="top">Output</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">3</td>
<td align="left" valign="top">Number of bytes</td>
<td align="left" valign="top">Output</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="left" valign="top">User buffer</td>
<td align="left" valign="top">Output</td>
<td align="left" valign="top">Char(*)</td>
</tr>
<tr>
<td align="center" valign="top">5</td>
<td align="left" valign="top">Line description</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Char(10)</td>
</tr>
<tr>
<td align="center" valign="top">6</td>
<td align="left" valign="top">Format</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Char(1)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Optional Parameter Group:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%">7</td>
<td align="left" valign="top" width="50%">Length of user buffer</td>
<td align="left" valign="top" width="20%">Input</td>
<td align="left" valign="top" width="20%">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">8</td>
<td align="left" valign="top">Bytes available</td>
<td align="left" valign="top">Output</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Default Public Authority: *USE<br>
<!-- iddvc RMBR -->
<br>
&nbsp;&nbsp;Threadsafe: No<br>
<!-- iddvc RMBR -->
<br>
</div>
<p>The Query Line Description (QOLQLIND) API queries an existing token-ring,
Ethernet, wireless, FDDI, frame relay, or X.25 line description. The data
received from the query is placed in the user buffer parameter.</p>
<p>The line description to be queried does not have to be associated with any
links the application program has enabled. However, data in the line
description may change after it is queried.</p>
<br>
<!-- Please NOTE: DO NOT DELETE THIS SECTION if this API has no authorities and locks. -->
<!-- Instead, use the commented out coding below to indicate NONE. -->
<h3>Authorities and Locks</h3>
<!-- Use this if there are no authorities and locks. -->
<p>None.</p>
<br>
<h3>Required Parameter Group</h3>
<dl>
<dt><strong>Return code</strong></dt>
<dd>OUTPUT; BINARY(4)
<p>The recovery action to take. See <a href="#HDRQLINDRR">Return and Reason
Codes</a>.</p>
</dd>
<dt><strong>Reason code</strong></dt>
<dd>OUTPUT; BINARY(4)
<p>The error that occurred. See <a href="#HDRQLINDRR">Return and Reason
Codes</a>.</p>
</dd>
<dt><strong>Number of bytes</strong></dt>
<dd>OUTPUT; BINARY(4)
<p>The number of bytes of data returned in the user buffer.</p>
</dd>
<dt><strong>User buffer</strong></dt>
<dd>OUTPUT; CHAR(*)
<p>The buffer where the data from the query will be received. Any unused space
in the buffer will be filled with X'00'. The length of this character structure
is determined using <a href="#FIGGRPP">User Buffer Format</a>.</p>
<p><strong><a name="FIGGRPP">User Buffer Format</a></strong></p>
<table border width="60%">
<tr>
<th valign="top">Format</th>
<th valign="top">Group Parameter Passed</th>
<th valign="top">Length of Char(*)</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">1</td>
<td align="center" valign="top" width="20%">No</td>
<td align="center" valign="top" width="70%">256</td>
</tr>
<tr>
<td align="center" valign="top" width="10%">1 or 2</td>
<td align="center" valign="top" width="20%">Yes</td>
<td align="center" valign="top" width="70%">Specified by the length user buffer
parameter.</td>
</tr>
</table>
<p><strong>Note:</strong> You are recommended to set the length user buffer
value to a number large enough to hold the system maximum values of virtual
circuits, SAPs, and group addresses with additional space left for future
needs.</p>
</dd>
<dt><strong>Line description</strong></dt>
<dd>INPUT; CHAR(10)
<p>The name of the line description to query. An existing token-ring, Ethernet,
wireless, FDDI, frame relay, or X.25 line description must be used.</p>
</dd>
<dt><strong>Format</strong></dt>
<dd>INPUT; CHAR(1)
<p>The format of the data returned in the user buffer. The valid values are as
follows:</p>
<table cellpadding="3">
<!-- cols="15 85" -->
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Use format 01.</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Use format 02.</td>
</tr>
</table>
<p>See <a href="#HDRQLINDFT">Format of Data in the User Buffer</a> for more
information.</p>
</dd>
</dl>
<br>
<h3>Optional Parameter Group</h3>
<dl>
<dt><strong>Length of user buffer</strong></dt>
<dd>INPUT; BINARY(4)
<p>The number of bytes available for the API to use in the user buffer
parameter. The valid values are from 0 to 32,767.</p>
<p><strong>Notes:</strong></p>
<ol>
<li>This parameter is required if format 2 is specified in the format
parameter. It is optional if format 1 is specified.<br>
<br>
</li>
<li>If length user buffer is specified, bytes available must also be
specified.<br>
<br>
</li>
<li>If additional information exists that could not be reported, the bytes
available parameter will contain a larger value than the bytes returned
parameter.</li>
</ol>
<br>
</dd>
<dt><strong>Bytes available</strong></dt>
<dd>OUTPUT; BINARY(4)
<p>The total number of bytes of available information.</p>
<p><strong>Notes:</strong></p>
<ol>
<li>This parameter is required if format 2 is specified in the format
parameter. It is optional if format 1 is specified.<br>
<br>
</li>
<li>If bytes available is specified, length user buffer must also be
specified.<br>
<br>
</li>
<li>If the bytes available parameter contains a number larger than the bytes
returned parameter, there is additional information that the application cannot
access.<br>
<br>
</li>
<li>If the return code parameter is nonzero, this value is set to zero.</li>
</ol>
</dd>
</dl>
<br>
<h3><a name="HDRQLINDFT">Format of Data in the User Buffer</a></h3>
<p>The data received in the user buffer from the query is made up of two parts.
The first portion starts at offset 0 from the top of the user buffer and
contains general query data. The format of this data does not depend on value
of the format parameter supplied to the QOLQLIND API.</p>
<p><strong><a name="Table_1-4">General Query Data</a></strong></p>
<table border width="80%">
<tr>
<th valign="top">Field</th>
<th valign="top">Type</th>
<th valign="top">Description</th>
</tr>
<tr>
<td align="left" valign="top" width="15%">Line description</td>
<td align="left" valign="top" width="15%">CHAR(10)</td>
<td align="left" valign="top" width="70%">The name of the token-ring, Ethernet,
wireless, FDDI, frame relay, or X.25 line description that was queried.</td>
</tr>
<tr>
<td align="left" valign="top">Line type</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The type of line description that was
queried. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'04'</em></td>
<td valign="top">X.25</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'05'</em></td>
<td valign="top">Token-ring</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'09'</em></td>
<td valign="top">Ethernet</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'0D'</em></td>
<td valign="top">FDDI</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'0E'</em></td>
<td valign="top">Frame relay</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'10'</em></td>
<td valign="top">Wireless</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Status</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The current status of the line
description. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Varied off</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Varied off pending</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Varied on pending</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">Varied on</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'04'</em></td>
<td valign="top">Active</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'05'</em></td>
<td valign="top">Connect pending</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'06'</em></td>
<td valign="top">Recovery pending</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'07'</em></td>
<td valign="top">Recovery canceled</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'08'</em></td>
<td valign="top">Failed</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'09'</em></td>
<td valign="top">Diagnostic mode</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'FF'</em></td>
<td valign="top">Unknown</td>
</tr>
</table>
<br>
</td>
</tr>
</table>
<p>The second portion of the user buffer starts immediately after the general
query data and contains data specific to the type of line description that was
queried. The format of this data depends on the value of the format parameter
supplied to the QOLQLIND API.</p>
<p><strong><a name="Table_1-5">LAN Specific Data-Format 01</a></strong></p>
<table border width="80%">
<tr>
<th valign="top">Field</th>
<th valign="top">Type</th>
<th valign="top">Description</th>
</tr>
<tr>
<td align="left" valign="top" width="15%">Local adapter address</td>
<td align="left" valign="top" width="15%">CHAR(6)</td>
<td align="left" valign="top" width="70%">Specifies, in packed form, the local
adapter address of this line. The special value of X'000000000000' indicates
that the preset default address for the adapter card was configured. However,
the line description must be varied on before this address can be
retrieved.</td>
</tr>
<tr>
<td align="left" valign="top">Line speed</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The speed of this line. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">4 megabits/second</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">10 megabits/second</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">16 megabits/second</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'04'</em></td>
<td valign="top">100 megabits/second</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Line capability</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The capability of this line. The
valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Non-Ethernet</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Ethernet Version 2</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Ethernet 802.3</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">Both Ethernet Version 2 and Ethernet 802.3</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Line frame size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The maximum frame size possible on
this line.</td>
</tr>
<tr>
<td align="left" valign="top">Ethernet Version 2 frame size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The maximum size for Ethernet Version
2 frames. This will be 1502 if the line is capable of Ethernet Version 2
traffic. Otherwise, it will be zero.</td>
</tr>
<tr>
<td align="left" valign="top">Number of SSAPs</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The number of source service access
points (SSAPs) configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
3 rows are repeated for each SSAP configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">SSAP</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The configured source service access
point.</td>
</tr>
<tr>
<td align="left" valign="top">SSAP type</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The SSAP type. The valid values are
as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Non-SNA SSAP</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">SNA SSAP</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">SSAP frame size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The maximum frame size allowed on
this SSAP.</td>
</tr>
<tr>
<td align="left" valign="top">Number of group addresses</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The number of group addresses
configured for this line.
<p><strong>Note:</strong> This will always be zero for a token-ring line
description.</p>
</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
row is repeated for each group address configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Group address</td>
<td align="left" valign="top">CHAR(6)</td>
<td align="left" valign="top">Specifies a group address, in packed
form.</td>
</tr>
</table>
<p><strong><a name="Table_1-6">LAN Specific Data-Format 02</a></strong></p>
<table border width="80%">
<tr>
<th valign="top">Field</th>
<th valign="top">Type</th>
<th valign="top">Description</th>
</tr>
<tr>
<td align="left" valign="top" width="15%">Local adapter address</td>
<td align="left" valign="top" width="15%">CHAR(6)</td>
<td align="left" valign="top" width="70%">Specifies, in packed form, the local
adapter address of this line. The special value of X'000000000000' indicates
that the preset default address for the adapter card was configured. However,
the line description must be varied on before this address can be
retrieved.</td>
</tr>
<tr>
<td align="left" valign="top">Line speed</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The speed of this line. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">4 megabits/second</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">10 megabits/second</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">16 megabits/second</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'04'</em></td>
<td valign="top">100 megabits/second</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'05'</em></td>
<td valign="top">Frame relay (line speed is specified separately)</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Line capability</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The capability of this line. The
valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Non-Ethernet</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Ethernet Version 2</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Ethernet 802.3</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">Both Ethernet Version 2 and Ethernet 802.3</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Line frame size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The maximum frame size possible on
this line.</td>
</tr>
<tr>
<td align="left" valign="top">Ethernet Version 2 frame size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The maximum size for Ethernet Version
2 frames. This will be 1502 if the line is capable of Ethernet Version 2
traffic. Otherwise, it will be zero.</td>
</tr>
<tr>
<td align="left" valign="top">Functional address field</td>
<td align="left" valign="top">CHAR(6)</td>
<td align="left" valign="top">The hexadecimal functional address
configured for the line. An address of X'000000000000' indicates there are no
functional addresses configured on this line description.</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> For additional
information on functional addresses, refer to the <cite>Token-Ring Architecture
Reference</cite> book, SC30-3374.</td>
</tr>
<tr>
<td align="left" valign="top">Number of group addresses</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The number of group addresses
configured for this line. This value is valid for Ethernet and wireless line
descriptions only.</td>
</tr>
<tr>
<td align="left" valign="top">Offset to group addresses</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">Offset within this structure to the
array of group addresses</td>
</tr>
<tr>
<td align="left" valign="top">Number of SSAPs</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The number of SSAPs configured for
this line.</td>
</tr>
<tr>
<td align="left" valign="top">Offset to SSAPs</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">Offset within this structure to the
array of SSAPs</td>
</tr>
<tr>
<td align="left" valign="top">FR line speed</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Frame relay line speed. This value is
valid only when the line type field is set to X'0E'.</td>
</tr>
<tr>
<td align="left" valign="top">Reserved</td>
<td align="left" valign="top">CHAR(*)</td>
<td align="left" valign="top">Reserved for extension</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
row is duplicated by the number of group addresses.</td>
</tr>
<tr>
<td align="left" valign="top">Group address</td>
<td align="left" valign="top">CHAR(6)</td>
<td align="left" valign="top">Specifies a group address, in packed
form.</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
three rows are duplicated by the number of SSAPs.</td>
</tr>
<tr>
<td align="left" valign="top">SSAP</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The configured source service access
point.</td>
</tr>
<tr>
<td align="left" valign="top">SSAP type</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The SSAP type. The valid values are
as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Non-SNA SSAP</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">SNA SSAP</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">SSAP frame size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The maximum frame size allowed on
this SSAP.</td>
</tr>
</table>
<p><strong><a name="Table_1-7">X.25 Specific Data-Format 01</a></strong></p>
<table border width="80%">
<tr>
<th valign="top">Field</th>
<th valign="top">Type</th>
<th valign="top">Description</th>
</tr>
<tr>
<td align="left" valign="top" width="15%">Local network address length</td>
<td align="left" valign="top" width="15%">CHAR(1)</td>
<td align="left" valign="top" width="70%">Specifies, in hexadecimal, the number
of binary coded decimal (BCD) digits in the local network address.</td>
</tr>
<tr>
<td align="left" valign="top">Local network address</td>
<td align="left" valign="top">CHAR(9)</td>
<td align="left" valign="top">Specifies, in BCD, the local network
address of this line.</td>
</tr>
<tr>
<td align="left" valign="top">Extended network addressing</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Specifies whether network addressing
is extended to permit the use of 17 digits in an address. The valid values are
as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Network addresses may be up to 15 digits</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Network addresses may be up to 17 digits</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Address insertion</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Specifies whether the system inserts
the local network address in call request and call accept packets. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>'Y'</em></td>
<td valign="top">The local network address is inserted in call request and call
accept packets.</td>
</tr>
<tr>
<td align="left" valign="top"><em>'N'</em></td>
<td valign="top">The local network address is not inserted in call request and
call accept packets.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Modulus</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The X.25 modulus value. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Modulus 8</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Modulus 128</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">X.25 DCE support</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Specifies whether the system
communicates using the integrated X.25 DCE support. This allows the system,
acting as the DCE, to communicate with another system without going through an
X.25 network. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">The system does not communicate using the X.25 DCE
support</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">The system does communicate using the X.25 DCE support</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">The system negotiates whether it communicates using the X.25
DCE support.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Transmit maximum packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The transmit maximum packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Receive maximum packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The receive maximum packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Transmit default packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The transmit default packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Receive default packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The receive default packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Transmit default window size</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">The transmit default window size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Receive default window size</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">The receive default window size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Number of logical channels</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The number of logical channels
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
4 rows are repeated for each logical channel configured for this line</td>
</tr>
<tr>
<td align="left" valign="top">Logical channel group number</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The logical channel group number.
This together with the logical channel number makes up the logical channel
identifier.</td>
</tr>
<tr>
<td align="left" valign="top">Logical channel number</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The logical channel number. This
together with the logical channel group number makes up the logical channel
identifier.</td>
</tr>
<tr>
<td align="left" valign="top">Logical channel type</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The logical channel type. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Switched virtual circuit (SVC).</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Permanent virtual circuit (PVC) that is eligible for use by a
network controller.
<p><strong>Note:</strong> This does not necessarily mean that this PVC is
available for use. Another job running on the network controller attached to
this line may already have this PVC in use.</p>
</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'22'</em></td>
<td valign="top">PVC that is not eligible for use by a network controller. For
example, a PVC that is already attached to an asynchronous controller
description.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Logical channel direction</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The direction of calls allowed on the
logical channel. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Not applicable (PVC logical channel).</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Only incoming calls are allowed on this logical channel.</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Only outgoing calls are allowed on this logical channel.</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">Both incoming and outgoing calls are allowed on this logical
channel.</td>
</tr>
</table>
<br>
</td>
</tr>
</table>
<p><strong><a name="Table_1-8">X.25 Specific Data-Format 02</a></strong></p>
<table border width="80%">
<tr>
<th valign="top">Field</th>
<th valign="top">Type</th>
<th valign="top">Description</th>
</tr>
<tr>
<td align="left" valign="top" width="15%">Local network address length</td>
<td align="left" valign="top" width="15%">CHAR(1)</td>
<td align="left" valign="top" width="70%">Specifies, in hexadecimal, the number
of binary coded decimal (BCD) digits in the local network address.</td>
</tr>
<tr>
<td align="left" valign="top">Local network address</td>
<td align="left" valign="top">CHAR(9)</td>
<td align="left" valign="top">Specifies, in BCD, the local network
address of this line.</td>
</tr>
<tr>
<td align="left" valign="top">Extended network addressing</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Specifies whether network addressing
is extended to permit the use of 17 digits in an address. The valid values are
as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Network addresses may be up to 15 digits</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Network addresses may be up to 17 digits</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Address insertion</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Specifies whether the system inserts
the local network address in call request and call accept packets. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>'Y'</em></td>
<td valign="top">The local network address is inserted in call request and call
accept packets.</td>
</tr>
<tr>
<td align="left" valign="top"><em>'N'</em></td>
<td valign="top">The local network address is not inserted in call request and
call accept packets.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Modulus</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The X.25 modulus value. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Modulus 8</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Modulus 128</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">X.25 DCE support</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Specifies whether the system
communicates using the integrated X.25 DCE support. This allows the system,
acting as a DCE, to communicate with another system without going through an
X.25 network. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">The system does not communicate using the X.25 DCE
support</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">The system does communicate using the X.25 DCE support</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">The system negotiates whether it communicates using the X.25
DCE support.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Transmit maximum packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The transmit maximum packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Receive maximum packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The receive maximum packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Transmit default packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The transmit default packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Receive default packet size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The receive default packet size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Transmit default window size</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">The transmit default window size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Receive default window size</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">The receive default window size
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Number of logical channels</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The number of logical channels
configured for this line.</td>
</tr>
<tr>
<td align="left" valign="top">Maximum frame size</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">The maximum frame size configured in
the line description. The valid values are as follows:
<ul>
<li>1024<br>
<br>
</li>
<li>2048<br>
<br>
</li>
<li>4096<br>
<br>
</li>
</ul>
</td>
</tr>
<tr>
<td align="left" valign="top">ISDN interface</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Indicates if the line uses an ISDN
interface. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">X.25 line does not run over an ISDN interface.</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">X.25 line runs over an ISDN interface.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
section applies only if the ISDN interface is specified as X'01'. The sections
of format 02 on the call direction field to the offset to logical channel array
field are not meaningful if an ISDN interface is not used and will return zeros
in these fields if an ISDN interface is not specified.</td>
</tr>
<tr>
<td align="left" valign="top">Call direction</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The direction of the ISDN call. The
valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Incoming switched call</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Outgoing switched call</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Either a nonswitched call or not ISDN-capable.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
fields are only meaningful if the line description is switched.</td>
</tr>
<tr>
<td align="left" valign="top">Length of call ID information</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">Length includes type and plan, as
described below, and the call identify information element.</td>
</tr>
<tr>
<td align="left" valign="top">Type of number and numbering
plan</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">Type and plan as represented by the
following bit sequence: tttt pppp, where tttt equals the category of the
calling number and pppp equals the numbering plan identification used when the
calling party number was created.<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>Type '0000 xxxx'</em></td>
<td valign="top">Unknown number</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type '0001 xxxx'</em></td>
<td valign="top">International number</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type '0010 xxxx'</em></td>
<td valign="top">National number</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type '0011 xxxx'</em></td>
<td valign="top">Network specific number</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type '0100 xxxx'</em></td>
<td valign="top">Subscriber number</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type '0110 xxxx'</em></td>
<td valign="top">Abbreviated number</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type '0111 xxxx'</em></td>
<td valign="top">Reserved for extension</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 0000'</em></td>
<td valign="top">Unknown</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 0001'</em></td>
<td valign="top">ISDN/telephony numbering plan</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 0011'</em></td>
<td valign="top">Data numbering plan</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 0100'</em></td>
<td valign="top">Telex numbering plan</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 1000'</em></td>
<td valign="top">National standard numbering plan</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 1001'</em></td>
<td valign="top">Private numbering plan</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 1111'</em></td>
<td valign="top">Reserved for extension</td>
</tr>
</table>
<p><strong>Note:</strong> Refer to CCITT Recommendation Q.931 for more
information.</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Reserved</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">Reserved for extension.</td>
</tr>
<tr>
<td align="left" valign="top">Call ID digits</td>
<td align="left" valign="top">CHAR(128)</td>
<td align="left" valign="top">Calling party number of remote system
received off the D-channel, specified in IA5 code (ASCII).</td>
</tr>
<tr>
<td align="left" valign="top">Length of subaddress information</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">Length includes type, odd-even
indicator, and the subaddress information element. Values can range from
X'0001' to X'00FF'. The user specified subaddress is restricted to 20
bytes.</td>
</tr>
<tr>
<td align="left" valign="top">Type of subaddress and odd-even
indicator</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">Type and odd-even indicator as
represented by the following bit sequence: tttt ixxx, where tttt equals the
type of subaddress and i equals whether the address has an even or odd number
of digits.<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>Type '0000 xxxx'</em></td>
<td valign="top">NSAP</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type '0010 xxxx'</em></td>
<td valign="top">User specified</td>
</tr>
<tr>
<td align="left" valign="top"><em>Type remaining</em></td>
<td valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 0xxx'</em></td>
<td valign="top">Even number of address digits</td>
</tr>
<tr>
<td align="left" valign="top"><em>Plan 'xxxx 1xxx'</em></td>
<td valign="top">Odd number of address digits</td>
</tr>
</table>
<p><strong>Note:</strong> Refer to CCITT Recommendation Q.931 for more
information.</p>
</td>
</tr>
<tr>
<td align="left" valign="top">Reserved</td>
<td align="left" valign="top">BINARY(1)</td>
<td align="left" valign="top">Reserved for extension.</td>
</tr>
<tr>
<td align="left" valign="top">Subaddress</td>
<td align="left" valign="top">CHAR(128)</td>
<td align="left" valign="top">Calling party subaddress information,
received from the D-channel, specified in the IA5 code set (a superset of
ASCII).</td>
</tr>
<tr>
<td align="left" valign="top">Offset to logical channel array</td>
<td align="left" valign="top">BINARY(2)</td>
<td align="left" valign="top">Offset within this structure to the
array of logical channels</td>
</tr>
<tr>
<td align="left" valign="top">Reserved</td>
<td align="left" valign="top">CHAR(*)</td>
<td align="left" valign="top">Reserved for extension</td>
</tr>
<tr>
<td align="left" valign="top" colspan="3"><strong>Note:</strong> The following
5 rows are repeated for each logical channel configured for this line. This
section is not specific to ISDN interfaces.</td>
</tr>
<tr>
<td align="left" valign="top">Logical channel group number</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The logical channel group number.
This together with the logical channel number makes up the logical channel
identifier.</td>
</tr>
<tr>
<td align="left" valign="top">Logical channel number</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The logical channel number. This
together with the logical channel group number makes up the logical channel
identifier.</td>
</tr>
<tr>
<td align="left" valign="top">Logical channel type</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">The logical channel type. The valid
values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Switched virtual circuit (SVC).</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Permanent virtual circuit (PVC) that is eligible for use by a
network controller.</td>
</tr>
</table>
<blockquote>
<p><strong>Note:</strong> This does not necessarily mean that this PVC is
available for use. Another job running on the network controller attached to
this line may already have this PVC in use.</p>
</blockquote>
</td>
</tr>
<tr>
<td align="left" valign="top">Type of calls allowed</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Types of calls supported on the
logical channel. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td>Not applicable (PVC logical channel).</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">Only incoming calls are allowed on this logical channel.</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'02'</em></td>
<td valign="top">Only outgoing calls are allowed on this logical channel.</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'03'</em></td>
<td valign="top">Both incoming and outgoing calls are allowed on this logical
channel.</td>
</tr>
</table>
<br>
</td>
</tr>
<tr>
<td align="left" valign="top">Availability</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Specifies whether the virtual circuit
is available or currently is in use. The valid values are as follows:<br>
<br>
<table cellpadding="3">
<tr>
<td align="left" valign="top"><em>X'00'</em></td>
<td valign="top">Available</td>
</tr>
<tr>
<td align="left" valign="top"><em>X'01'</em></td>
<td valign="top">In use</td>
</tr>
</table>
<br>
</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRQLINDRR">Return and Reason Codes</a></h3>
<p><strong><a name="Table_1-9">Return and Reason Codes for the QOLQLIND
API</a></strong></p>
<table border width="80%">
<tr>
<th valign="bottom">Return / Reason Code</th>
<th valign="bottom">Meaning</th>
<th valign="bottom">Recovery</th>
</tr>
<tr>
<td align="center" valign="top" width="15%">00/0000</td>
<td align="left" valign="top" width="20%">Operation successful.</td>
<td align="left" valign="top" width="65%">Continue processing.
<p><strong>Notes:</strong></p>
<ol>
<li>When calling QOLQLIND (specifying an X.25 line description, format 1, and
not specifying group parameters), up to 54 logical channels can be contained in
the user buffer because it is limited to a size of 256 bytes. To increase the
size of the user buffer so that it is sufficient to contain all of the logical
channels, the group parameters should be used. To determine if there are more
than 54 logical channels configured, use the Display Line Description (DSPLIND)
command.<br>
<br>
</li>
<li>The application should check to ensure that the bytes available value
returned is less than or equal to the bytes returned value. If so, there is
additional information that the application may want to receive. To receive
this information, the application must re-issue the call, specifying the length
user buffer equal to or greater than the bytes available value.</li>
</ol>
</td>
</tr>
<tr>
<td align="center" valign="top">81/9999</td>
<td align="left" valign="top">Internal system error detected.
Escape message CPF91F0 will be sent to the application program when this return
and reason code is received.</td>
<td align="left" valign="top">See messages in the job log for
further information. Report the problem using the ANZPRB command.</td>
</tr>
<tr>
<td align="center" valign="top">83/1005</td>
<td align="left" valign="top">Format not valid.</td>
<td align="left" valign="top">Correct the format parameter. Try the
request again.</td>
</tr>
<tr>
<td align="center" valign="top">83/1014</td>
<td align="left" valign="top">Length user buffer value not valid.
This value cannot be negative.</td>
<td align="left" valign="top">Correct the length user buffer value
to a zero or a positive value less than 32K and try the operation again.</td>
</tr>
<tr>
<td align="center" valign="top">83/1020</td>
<td align="left" valign="top">Group parameters not valid.</td>
<td align="left" valign="top">All parameters within the group must
be specified. Correct the parameter list and try the request again.</td>
</tr>
<tr>
<td align="center" valign="top">83/1021</td>
<td align="left" valign="top">Required parameter not
specified.</td>
<td align="left" valign="top">Format 2 was requested and the
required group parameters (length user buffer and bytes available) were not
specified. Correct the parameter list and try the request again.</td>
</tr>
<tr>
<td align="center" valign="top">83/1998</td>
<td align="left" valign="top">User buffer parameter too small.</td>
<td align="left" valign="top">Either the length user buffer value
is negative or it contains a positive value and the system was not able to put
the data into the user buffer provided by the application. Correct the
application and try the request again.</td>
</tr>
<tr>
<td align="center" valign="top">83/2000</td>
<td align="left" valign="top">Line description not configured for
token-ring, Ethernet, wireless, or X.25.</td>
<td align="left" valign="top">Correct the line description
parameter. Try the request again.</td>
</tr>
<tr>
<td align="center" valign="top">83/2002</td>
<td align="left" valign="top">Not authorized to line
description.</td>
<td align="left" valign="top">Get authorization to the line
description. Try the request again.</td>
</tr>
<tr>
<td align="center" valign="top">83/2006</td>
<td align="left" valign="top">Line description not found.</td>
<td align="left" valign="top">Correct the line description
parameter. Try the request again.</td>
</tr>
<tr>
<td align="center" valign="top">83/2007</td>
<td align="left" valign="top">Line description damaged.</td>
<td align="left" valign="top">Delete and re-create the line
description. Try the request again.</td>
</tr>
</table>
<br>
<br>
<h3>Error Messages</h3>
<table width="100%" cellpadding="3">
<!-- cols="15 85" -->
<tr>
<th align="left" valign="top">Message ID</th>
<th align="left" valign="top">Error Message Text</th>
</tr>
<tr>
<td align="left" valign="top">CPF3C90 E</td>
<td valign="top">Literal value cannot be changed.</td>
</tr>
<tr>
<td align="left" valign="top">CPF91F0 E</td>
<td valign="top">Internal system error.</td>
</tr>
<tr>
<td align="left" valign="top">CPF9872 E</td>
<td valign="top">Program or service program &amp;1 in library &amp;2 ended.
Reason code &amp;3.</td>
</tr>
</table>
<br>
<hr>
API introduced: V2R1
<hr>
<center>
<table cellpadding="2" cellspacing="2">
<tr align="center">
<td valign="middle" align="center"><a href="#Top_Of_Page">Top</a> | <a href=
"comm.htm">Communications APIs</a> | <a href="aplist.htm">APIs by
category</a></td>
</tr>
</table>
</center>
</body>
</html>