<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8">
<meta name="Copyright" content="Copyright (c) 2006 by IBM Corporation">
<title>Retrieve Line Description (QDCRLIND) API</title>
<!-- Begin Header Records ========================================= -->
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<!-- Cnfg1 SCRIPT J converted by B2H R4.1 (346) (CMS) by V2KEA304 -->
<!-- at RCHVMW2 on 12 May 1999 at 12:05:09 -->
<!-- Change History: -->
<!-- YYMMDD USERID Change description -->
<!-- File cleanup completed Jan 2002 by v2cdijab -->
<!-- D99395.1 Ethernet Enhancements 10/28/02 V01176 -->
<!-- D99680 ISDN and ATM NWI removal 05/21/03 maryhs -->
<!-- End Header Records -->
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
</head>
<body>
<a name="Top_Of_Page"></a>
<!-- Java sync-link -->
<script type="text/javascript" language="Javascript" src="../rzahg/synch.js">
</script>
<h2>Retrieve Line Description (QDCRLIND) API</h2>
<div class="box" style="width: 70%;">
&nbsp;&nbsp;Required Parameter Group:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%">1</td>
<td align="left" valign="top" width="50%">Receiver variable</td>
<td align="left" valign="top" width="20%">Output</td>
<td align="left" valign="top" width="20%">Char(*)</td>
</tr>
<tr>
<td align="center" valign="top">2</td>
<td align="left" valign="top">Length of receiver variable</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">3</td>
<td align="left" valign="top">Format name</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Char(8)</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="left" valign="top">Line name</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Char(10)</td>
</tr>
<tr>
<td align="center" valign="top">5</td>
<td align="left" valign="top">Error code</td>
<td align="left" valign="top">I/O</td>
<td align="left" valign="top">Char(*)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Default Public Authority: *USE<br>
<!-- iddvc RMBR -->
<br>
&nbsp;&nbsp;Threadsafe: Yes<br>
<!-- iddvc RMBR -->
<br>
</div>
<p>The Retrieve Line Description (QDCRLIND) API retrieves information about a
line description.</p>
<br>
<h3>Authorities and Locks</h3>
<dl>
<dt><em>Controller Description Authority</em></dt>
<dd>*USE</dd>
<dt><em>Line Description Authority</em></dt>
<dd>*USE</dd>
<dt><em>Controller Description Lock</em></dt>
<dd>*EXCLRD</dd>
<dt><em>Line Description Lock</em></dt>
<dd>*EXCLRD</dd>
</dl>
<br>
<h3>Required Parameter Group</h3>
<dl>
<dt><strong>Receiver variable</strong></dt>
<dd>OUTPUT; CHAR(*)
<p>The variable that is to receive the line information.</p>
</dd>
<dt><strong>Length of receiver variable</strong></dt>
<dd>INPUT; BINARY(4)
<p>The length of the area referenced by the receiver variable parameter. If the
amount of information to be returned is greater than this value, the
information will be truncated to this length.</p>
</dd>
<dt><strong>Format name</strong></dt>
<dd>INPUT; CHAR(8)
<p>The content and format of the information returned for each line
description. The possible format names are:</p>
<table cellpadding="5">
<!-- cols="15 85" -->
<tr>
<td align="left" valign="top"><em>LIND0100</em></td>
<td align="left" valign="top">Basic line information</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0200</em></td>
<td align="left" valign="top">Basic line information, plus list of attached
nonswitched controllers</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0300</em></td>
<td align="left" valign="top">Detailed information for line category *ASC</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0400</em></td>
<td align="left" valign="top">Detailed information for line category *BSC</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0500</em></td>
<td align="left" valign="top">Detailed information for line category *ETH</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0600</em></td>
<td align="left" valign="top">Detailed information for line category *IDLC</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0700</em></td>
<td align="left" valign="top">Detailed information for line category *NET</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0800</em></td>
<td align="left" valign="top">Detailed information for line category *SDLC</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND0900</em></td>
<td align="left" valign="top">Detailed information for line category *TDLC</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND1000</em></td>
<td align="left" valign="top">Detailed information for line category *TRN</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND1100</em></td>
<td align="left" valign="top">Detailed information for line category *X25</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND1200</em></td>
<td align="left" valign="top">Detailed information for line category *DDI</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND1300</em></td>
<td align="left" valign="top">Detailed information for line category *FR</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND1400</em></td>
<td align="left" valign="top">Detailed information for line category *FAX</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND1500</em></td>
<td align="left" valign="top">Detailed information for line category *WLS</td>
</tr>
<tr>
<td align="left" valign="top"><em>LIND1600</em></td>
<td align="left" valign="top">Detailed information for line category *PPP</td>
</tr>
</table>
<p><strong>Note:</strong> Formats LIND0600 and LIND0700 are no longer supported.</p>
<p>See <a href="#HDRLINDFMT">Format of Line Information</a> for a description
of these formats.</p>
</dd>
<dt><strong>Line name</strong></dt>
<dd>INPUT; CHAR(10)
<p>The name of the line description to be retrieved.</p>
</dd>
<dt><strong>Error code</strong></dt>
<dd>I/O; CHAR(*)
<p>The structure in which to return error information. For the format of the
structure, see <a href="../apiref/error.htm#hdrerrcod">Error Code Parameter</a>.</p>
</dd>
</dl>
<br>
<h3><a name="HDRLINDFMT">Format of Line Information</a></h3>
<p>When the line category is unknown, specify LIND0100 or LIND0200, and the
basic information (including line category) will be returned. When the line
category is known, specify one of the other category-specific formats.</p>
<p>For detailed descriptions of the fields returned in these formats, see
<a href="#HDRLINDFLD">Field Descriptions</a>.</p>
<br>
<h3><a name="HDRLIND1">LIND0100 Format</a></h3>
<p>Use this format to find out the line category, plus some basic information
about the line. Then you may use the returned line category to select one of
the other (category-specific) formats to call the API again for detailed
information about the line description. This format also returns the number of
controllers currently attached to this line.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">BINARY(4)</td>
<td align="left" valign="top" width="60%">Bytes returned</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="center" valign="top">4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Bytes available</td>
</tr>
<tr>
<td align="center" valign="top">8</td>
<td align="center" valign="top">8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of attached nonswitched controllers</td>
</tr>
<tr>
<td align="center" valign="top">12</td>
<td align="center" valign="top">C</td>
<td align="left" valign="top">CHAR(7)</td>
<td align="left" valign="top">Date information retrieved</td>
</tr>
<tr>
<td align="center" valign="top">19</td>
<td align="center" valign="top">13</td>
<td align="left" valign="top">CHAR(6)</td>
<td align="left" valign="top">Time information retrieved</td>
</tr>
<tr>
<td align="center" valign="top">25</td>
<td align="center" valign="top">19</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Line name</td>
</tr>
<tr>
<td align="center" valign="top">35</td>
<td align="center" valign="top">23</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Line category</td>
</tr>
<tr>
<td align="center" valign="top">45</td>
<td align="center" valign="top">2D</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Online at IPL</td>
</tr>
<tr>
<td align="center" valign="top">55</td>
<td align="center" valign="top">37</td>
<td align="left" valign="top">CHAR(50)</td>
<td align="left" valign="top">Text description</td>
</tr>
<tr>
<td align="center" valign="top">105</td>
<td align="center" valign="top">69</td>
<td align="left" valign="top">CHAR(3)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND2">LIND0200 Format</a></h3>
<p>This format returns basic line information, plus a list of attached
nonswitched controllers. Some basic information is also included for each
attached nonswitched controller.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="4">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Controller category</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Controller type</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(50)</td>
<td align="left" valign="top">Controller text description</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND3">LIND0300 Format</a></h3>
<p>This format returns detailed information about a line of category *ASC.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line speed</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Inactivity timer</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum buffer size</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Idle timer</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Data Set Ready drop timer</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Clear to Send timer</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Remote answer timer</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of EOR characters</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of EOR characters</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of EOR characters</td>
</tr>
<tr>
<td align="center" valign="top">192</td>
<td align="center" valign="top">C0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">202</td>
<td align="center" valign="top">CA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Physical Interface</td>
</tr>
<tr>
<td align="center" valign="top">212</td>
<td align="center" valign="top">D4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection type</td>
</tr>
<tr>
<td align="center" valign="top">222</td>
<td align="center" valign="top">DE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched network backup</td>
</tr>
<tr>
<td align="center" valign="top">232</td>
<td align="center" valign="top">E8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Activate switched network backup</td>
</tr>
<tr>
<td align="center" valign="top">242</td>
<td align="center" valign="top">F2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall unit</td>
</tr>
<tr>
<td align="center" valign="top">252</td>
<td align="center" valign="top">FC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Data bits per character</td>
</tr>
<tr>
<td align="center" valign="top">262</td>
<td align="center" valign="top">106</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Type of parity</td>
</tr>
<tr>
<td align="center" valign="top">272</td>
<td align="center" valign="top">110</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Stop bits</td>
</tr>
<tr>
<td align="center" valign="top">282</td>
<td align="center" valign="top">11A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Duplex</td>
</tr>
<tr>
<td align="center" valign="top">292</td>
<td align="center" valign="top">124</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Echo support</td>
</tr>
<tr>
<td align="center" valign="top">302</td>
<td align="center" valign="top">12E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem type supported</td>
</tr>
<tr>
<td align="center" valign="top">312</td>
<td align="center" valign="top">138</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem data rate select</td>
</tr>
<tr>
<td align="center" valign="top">322</td>
<td align="center" valign="top">142</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched connection type</td>
</tr>
<tr>
<td align="center" valign="top">332</td>
<td align="center" valign="top">14C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer</td>
</tr>
<tr>
<td align="center" valign="top">342</td>
<td align="center" valign="top">156</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autodial</td>
</tr>
<tr>
<td align="center" valign="top">352</td>
<td align="center" valign="top">160</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Dial command type</td>
</tr>
<tr>
<td align="center" valign="top">362</td>
<td align="center" valign="top">16A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall resource name</td>
</tr>
<tr>
<td align="center" valign="top">372</td>
<td align="center" valign="top">174</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Calling number</td>
</tr>
<tr>
<td align="center" valign="top">404</td>
<td align="center" valign="top">194</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Error threshold level</td>
</tr>
<tr>
<td align="center" valign="top">414</td>
<td align="center" valign="top">19E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Flow control</td>
</tr>
<tr>
<td align="center" valign="top">424</td>
<td align="center" valign="top">1A8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">XON character</td>
</tr>
<tr>
<td align="center" valign="top">434</td>
<td align="center" valign="top">1B2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">XOFF character</td>
</tr>
<tr>
<td align="center" valign="top">444</td>
<td align="center" valign="top">1BC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer type</td>
</tr>
<tr>
<td align="center" valign="top">454</td>
<td align="center" valign="top">1C6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoconfigured for AS/36</td>
</tr>
<tr>
<td align="center" valign="top">464</td>
<td align="center" valign="top">1D0</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="center" valign="top">466</td>
<td align="center" valign="top">1D2</td>
<td align="left" valign="top">CHAR(40)</td>
<td align="left" valign="top">Set modem to ASYNC command</td>
</tr>
<tr>
<td align="center" valign="top">506</td>
<td align="center" valign="top">1FA</td>
<td align="left" valign="top">CHAR(60)</td>
<td align="left" valign="top">Modem initialization command</td>
</tr>
<tr>
<td align="center" valign="top">566</td>
<td align="center" valign="top">236</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">576</td>
<td align="center" valign="top">240</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">586</td>
<td align="center" valign="top">24a</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="3">These fields repeat for
each EOR character</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of trailing characters</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">EOR character</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND4">LIND0400 Format</a></h3>
<p>This format returns detailed information about a line of category *BSC.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line speed</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Inactivity timer</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum buffer size</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Receive timer</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Continue timer</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Contention state retry</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Data state retry</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Transmit TTD or WACK retry</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Receive TTD or WACK retry</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Data Set Ready drop timer</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Clear To Send timer</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Remote answer timer</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">192</td>
<td align="center" valign="top">C0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">196</td>
<td align="center" valign="top">C4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">200</td>
<td align="center" valign="top">C8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">210</td>
<td align="center" valign="top">D2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Application type</td>
</tr>
<tr>
<td align="center" valign="top">220</td>
<td align="center" valign="top">DC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Physical Interface</td>
</tr>
<tr>
<td align="center" valign="top">230</td>
<td align="center" valign="top">E6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection type</td>
</tr>
<tr>
<td align="center" valign="top">240</td>
<td align="center" valign="top">F0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched network backup</td>
</tr>
<tr>
<td align="center" valign="top">250</td>
<td align="center" valign="top">FA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Activate switched network backup</td>
</tr>
<tr>
<td align="center" valign="top">260</td>
<td align="center" valign="top">104</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall unit</td>
</tr>
<tr>
<td align="center" valign="top">270</td>
<td align="center" valign="top">10E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Station address</td>
</tr>
<tr>
<td align="center" valign="top">280</td>
<td align="center" valign="top">118</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Clocking</td>
</tr>
<tr>
<td align="center" valign="top">290</td>
<td align="center" valign="top">122</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Duplex</td>
</tr>
<tr>
<td align="center" valign="top">300</td>
<td align="center" valign="top">12C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem type supported</td>
</tr>
<tr>
<td align="center" valign="top">310</td>
<td align="center" valign="top">136</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem data rate select</td>
</tr>
<tr>
<td align="center" valign="top">320</td>
<td align="center" valign="top">140</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched connection type</td>
</tr>
<tr>
<td align="center" valign="top">330</td>
<td align="center" valign="top">14A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer</td>
</tr>
<tr>
<td align="center" valign="top">340</td>
<td align="center" valign="top">154</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autodial</td>
</tr>
<tr>
<td align="center" valign="top">350</td>
<td align="center" valign="top">15E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Dial command type</td>
</tr>
<tr>
<td align="center" valign="top">360</td>
<td align="center" valign="top">168</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall resource name</td>
</tr>
<tr>
<td align="center" valign="top">370</td>
<td align="center" valign="top">172</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Calling number</td>
</tr>
<tr>
<td align="center" valign="top">402</td>
<td align="center" valign="top">192</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Character code</td>
</tr>
<tr>
<td align="center" valign="top">412</td>
<td align="center" valign="top">19C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SYN characters</td>
</tr>
<tr>
<td align="center" valign="top">422</td>
<td align="center" valign="top">1A6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Error threshold level</td>
</tr>
<tr>
<td align="center" valign="top">432</td>
<td align="center" valign="top">1B0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Include STX character in the LRC</td>
</tr>
<tr>
<td align="center" valign="top">442</td>
<td align="center" valign="top">1BA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer type</td>
</tr>
<tr>
<td align="center" valign="top">452</td>
<td align="center" valign="top">1C4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoconfigured for AS/36</td>
</tr>
<tr>
<td align="center" valign="top">462</td>
<td align="center" valign="top">1CE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">472</td>
<td align="center" valign="top">1D8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">482</td>
<td align="center" valign="top">1E2</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND5">LIND0500 Format</a></h3>
<p>This format returns detailed information about a line of category *ETH.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Autodelete controller</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">198</td>
<td align="center" valign="top">C6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">208</td>
<td align="center" valign="top">D0</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Local adapter address</td>
</tr>
<tr>
<td align="center" valign="top">220</td>
<td align="center" valign="top">DC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">230</td>
<td align="center" valign="top">E6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Ethernet standard</td>
</tr>
<tr>
<td align="center" valign="top">240</td>
<td align="center" valign="top">F0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Error threshold level</td>
</tr>
<tr>
<td align="center" valign="top">250</td>
<td align="center" valign="top">FA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">260</td>
<td align="center" valign="top">104</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">270</td>
<td align="center" valign="top">10E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocreate controller</td>
</tr>
<tr>
<td align="center" valign="top">280</td>
<td align="center" valign="top">118</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Port number</td>
</tr>
<tr>
<td align="center" valign="top">284</td>
<td align="center" valign="top">11C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched NWI</td>
</tr>
<tr>
<td align="center" valign="top">294</td>
<td align="center" valign="top">128</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network interface DLC identifier</td>
</tr>
<tr>
<td align="center" valign="top">304</td>
<td align="center" valign="top">130</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network server description</td>
</tr>
<tr>
<td align="center" valign="top">314</td>
<td align="center" valign="top">13A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Duplex</td>
</tr>
<tr>
<td align="center" valign="top">324</td>
<td align="center" valign="top">144</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line Speed</td>
</tr>
<tr>
<td align="center" valign="top">328</td>
<td align="center" valign="top">148</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Generate test frame</td>
</tr>
<tr>
<td align="center" valign="top">338</td>
<td align="center" valign="top">152</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="center" valign="top">340</td>
<td align="center" valign="top">154</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">LAN emulation client (LEC) cache aging time</td>
</tr>
<tr>
<td align="center" valign="top">344</td>
<td align="center" valign="top">158</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Address resolution protocol (ARP) retry
count</td>
</tr>
<tr>
<td align="center" valign="top">348</td>
<td align="center" valign="top">15C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Address resolution protocol (ARP) retry
timer</td>
</tr>
<tr>
<td align="center" valign="top">352</td>
<td align="center" valign="top">160</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum address resolution protocol (ARP)
entries</td>
</tr>
<tr>
<td align="center" valign="top">356</td>
<td align="center" valign="top">164</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">LAN emulation client (LEC) disconnect time
out</td>
</tr>
<tr>
<td align="center" valign="top">360</td>
<td align="center" valign="top">168</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of PVC identifiers</td>
</tr>
<tr>
<td align="center" valign="top">364</td>
<td align="center" valign="top">16C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of PVC identifiers</td>
</tr>
<tr>
<td align="center" valign="top">368</td>
<td align="center" valign="top">170</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of PVC identifiers</td>
</tr>
<tr>
<td align="center" valign="top">372</td>
<td align="center" valign="top">174</td>
<td align="left" valign="top">CHAR(13)</td>
<td align="left" valign="top">ATM access type</td>
</tr>
<tr>
<td align="center" valign="top">385</td>
<td align="center" valign="top">181</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Emulated LAN name</td>
</tr>
<tr>
<td align="center" valign="top">417</td>
<td align="center" valign="top">1A1</td>
<td align="left" valign="top">CHAR(26)</td>
<td align="left" valign="top">Local ATM address: network prefix</td>
</tr>
<tr>
<td align="center" valign="top">443</td>
<td align="center" valign="top">1BB</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Local ATM address: end-system-identifier</td>
</tr>
<tr>
<td align="center" valign="top">455</td>
<td align="center" valign="top">1C7</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Local ATM address: LAN emulation client (LEC)
selector byte</td>
</tr>
<tr>
<td align="center" valign="top">457</td>
<td align="center" valign="top">1C9</td>
<td align="left" valign="top">CHAR(26)</td>
<td align="left" valign="top">LAN emulation server (LES) ATM address: network
prefix</td>
</tr>
<tr>
<td align="center" valign="top">483</td>
<td align="center" valign="top">1E3</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">LAN emulation server (LES) ATM address: end
system identifier</td>
</tr>
<tr>
<td align="center" valign="top">495</td>
<td align="center" valign="top">1EF</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">LAN emulation server (LES) ATM address: selector
byte</td>
</tr>
<tr>
<td align="center" valign="top">497</td>
<td align="center" valign="top">1F1</td>
<td align="left" valign="top">CHAR(26)</td>
<td align="left" valign="top">Last contacted LAN emulation server (LES) ATM
address: network prefix</td>
</tr>
<tr>
<td align="center" valign="top">523</td>
<td align="center" valign="top">20B</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Last contacted LAN emulation server (LES) ATM
address: end system identifier</td>
</tr>
<tr>
<td align="center" valign="top">535</td>
<td align="center" valign="top">217</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Last contacted LAN emulation server (LES) ATM
address: selector byte</td>
</tr>
<tr>
<td align="center" valign="top">537</td>
<td align="center" valign="top">219</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Use LAN emulation configuration server (LECS)
address</td>
</tr>
<tr>
<td align="center" valign="top">547</td>
<td align="center" valign="top">223</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network interface type</td>
</tr>
<tr>
<td align="center" valign="top">557</td>
<td align="center" valign="top">22D</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Reported emulated LAN name</td>
</tr>
<tr>
<td align="center" valign="top">589</td>
<td align="center" valign="top">24D</td>
<td align="left" valign="top">CHAR(3)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="center" valign="top">592</td>
<td align="center" valign="top">250</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">LAN emulation client (LEC) frame size</td>
</tr>
<tr>
<td align="center" valign="top">596</td>
<td align="center" valign="top">254</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed multiplier</td>
</tr>
<tr>
<td align="center" valign="top">600</td>
<td align="center" valign="top">258</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">610</td>
<td align="center" valign="top">262</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">620</td>
<td align="center" valign="top">26C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">630</td>
<td align="center" valign="top">276</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">640</td>
<td align="center" valign="top">280</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Enable for TCP/IP</td>
</tr>
<tr>
<td align="center" valign="top">650</td>
<td align="center" valign="top">28A</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="center" valign="top">652</td>
<td align="center" valign="top">28C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">656</td>
<td align="center" valign="top">290</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Current line speed</td>
</tr>
<tr>
<td align="center" valign="top">660</td>
<td align="center" valign="top">294</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current duplex</td>
</tr>
<tr>
<td align="center" valign="top">670</td>
<td align="center" valign="top">29E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Virtual hardware</td>
</tr>
<tr>
<td align="center" valign="top">680</td>
<td align="center" valign="top">2A8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Associated port resource name</td>
</tr>
<tr>
<td align="center" valign="top">690</td>
<td align="center" valign="top">2B2</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">IOP attach flag</td>
</tr>
<tr>
<td align="center" valign="top">691</td>
<td align="center" valign="top">2B3</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="3">These fields repeat for
each SSAP</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SSAP maximum frame</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP address</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP type</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2">This field repeats for each group
address</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Group address</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2">This field repeats for each PVC
identifier</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">PVC identifier</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND6">LIND0600 Format</a></h3>
<p>This format returns detailed information about a line of category *IDLC.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line speed</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">CRC errors received</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Short frame</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Receive overrun</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Transmit underrun</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Frame aborts</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Retransmitted frames</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Frame sequence errors</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Default window size</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Frame retry limit</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Response timer</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Connect retry count</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">192</td>
<td align="center" valign="top">C0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">196</td>
<td align="center" valign="top">C4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">200</td>
<td align="center" valign="top">C8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">204</td>
<td align="center" valign="top">CC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">208</td>
<td align="center" valign="top">D0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">212</td>
<td align="center" valign="top">D4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">216</td>
<td align="center" valign="top">D8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">220</td>
<td align="center" valign="top">DC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">224</td>
<td align="center" valign="top">E0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">228</td>
<td align="center" valign="top">E4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection type</td>
</tr>
<tr>
<td align="center" valign="top">238</td>
<td align="center" valign="top">EE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched NWI</td>
</tr>
<tr>
<td align="center" valign="top">248</td>
<td align="center" valign="top">F8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel type</td>
</tr>
<tr>
<td align="center" valign="top">258</td>
<td align="center" valign="top">102</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel number</td>
</tr>
<tr>
<td align="center" valign="top">268</td>
<td align="center" valign="top">10C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched connection type</td>
</tr>
<tr>
<td align="center" valign="top">278</td>
<td align="center" valign="top">116</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection list</td>
</tr>
<tr>
<td align="center" valign="top">288</td>
<td align="center" valign="top">120</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">298</td>
<td align="center" valign="top">12A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Error threshold level</td>
</tr>
<tr>
<td align="center" valign="top">308</td>
<td align="center" valign="top">134</td>
<td align="left" valign="top">CHAR(13)</td>
<td align="left" valign="top">Information transfer type</td>
</tr>
<tr>
<td align="center" valign="top">321</td>
<td align="center" valign="top">141</td>
<td align="left" valign="top">CHAR(10</td>
<td align="left" valign="top">Switched NWI selection</td>
</tr>
<tr>
<td align="center" valign="top">331</td>
<td align="center" valign="top">14B</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">341</td>
<td align="center" valign="top">155</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">351</td>
<td align="center" valign="top">15F</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">361</td>
<td align="center" valign="top">169</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="4">These fields repeat for
each switched NWI</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel type</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel number</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND7">LIND0700 Format</a></h3>
<p>This format returns detailed information about a line of category *NET.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched NWI</td>
</tr>
<tr>
<td align="center" valign="top">126</td>
<td align="center" valign="top">7E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND8">LIND0800 Format</a></h3>
<p>This format returns detailed information about a line of category *SDLC.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line speed</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SHM call timer</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SHM maximum connect timer</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SHM answer delay timer</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Connect poll retry</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Connect timer</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Short timer</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Long timer</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Short retry</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Long retry</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum outstanding frames</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Inactivity timer</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Poll response delay</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Nonproductive receive timer</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Idle timer</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Connect poll timer</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Poll cycle pause</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Frame retry</td>
</tr>
<tr>
<td align="center" valign="top">192</td>
<td align="center" valign="top">C0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Fair polling timer</td>
</tr>
<tr>
<td align="center" valign="top">196</td>
<td align="center" valign="top">C4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Data Set Ready drop timer</td>
</tr>
<tr>
<td align="center" valign="top">200</td>
<td align="center" valign="top">C8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Clear To Send timer</td>
</tr>
<tr>
<td align="center" valign="top">204</td>
<td align="center" valign="top">CC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Remote answer timer</td>
</tr>
<tr>
<td align="center" valign="top">208</td>
<td align="center" valign="top">D0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">212</td>
<td align="center" valign="top">D4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">216</td>
<td align="center" valign="top">D8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">220</td>
<td align="center" valign="top">DC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">224</td>
<td align="center" valign="top">E0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">228</td>
<td align="center" valign="top">E4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">232</td>
<td align="center" valign="top">E8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">236</td>
<td align="center" valign="top">EC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">240</td>
<td align="center" valign="top">F0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">244</td>
<td align="center" valign="top">F4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">248</td>
<td align="center" valign="top">F8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">252</td>
<td align="center" valign="top">FC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">256</td>
<td align="center" valign="top">100</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">260</td>
<td align="center" valign="top">104</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of resource names</td>
</tr>
<tr>
<td align="center" valign="top">264</td>
<td align="center" valign="top">108</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of resource names</td>
</tr>
<tr>
<td align="center" valign="top">268</td>
<td align="center" valign="top">10C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of resource names</td>
</tr>
<tr>
<td align="center" valign="top">272</td>
<td align="center" valign="top">110</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of call progress signal retry
values</td>
</tr>
<tr>
<td align="center" valign="top">276</td>
<td align="center" valign="top">114</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of call progress signal retry values</td>
</tr>
<tr>
<td align="center" valign="top">280</td>
<td align="center" valign="top">118</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of call progress signal
retry values</td>
</tr>
<tr>
<td align="center" valign="top">284</td>
<td align="center" valign="top">11C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Data link role</td>
</tr>
<tr>
<td align="center" valign="top">294</td>
<td align="center" valign="top">126</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Physical interface</td>
</tr>
<tr>
<td align="center" valign="top">304</td>
<td align="center" valign="top">130</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection type</td>
</tr>
<tr>
<td align="center" valign="top">314</td>
<td align="center" valign="top">13A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched network backup</td>
</tr>
<tr>
<td align="center" valign="top">324</td>
<td align="center" valign="top">144</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Activate switched network backup</td>
</tr>
<tr>
<td align="center" valign="top">334</td>
<td align="center" valign="top">14E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SHM node type</td>
</tr>
<tr>
<td align="center" valign="top">344</td>
<td align="center" valign="top">158</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall unit</td>
</tr>
<tr>
<td align="center" valign="top">354</td>
<td align="center" valign="top">162</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">364</td>
<td align="center" valign="top">16C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NRZI data encoding</td>
</tr>
<tr>
<td align="center" valign="top">374</td>
<td align="center" valign="top">176</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Clocking</td>
</tr>
<tr>
<td align="center" valign="top">384</td>
<td align="center" valign="top">180</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem type supported</td>
</tr>
<tr>
<td align="center" valign="top">394</td>
<td align="center" valign="top">18A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem data rate select</td>
</tr>
<tr>
<td align="center" valign="top">404</td>
<td align="center" valign="top">194</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched connection type</td>
</tr>
<tr>
<td align="center" valign="top">414</td>
<td align="center" valign="top">19E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer</td>
</tr>
<tr>
<td align="center" valign="top">424</td>
<td align="center" valign="top">1A8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autodial</td>
</tr>
<tr>
<td align="center" valign="top">434</td>
<td align="center" valign="top">1B2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Dial command type</td>
</tr>
<tr>
<td align="center" valign="top">444</td>
<td align="center" valign="top">1BC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall resource name</td>
</tr>
<tr>
<td align="center" valign="top">454</td>
<td align="center" valign="top">1C6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SHM call format</td>
</tr>
<tr>
<td align="center" valign="top">464</td>
<td align="center" valign="top">1D0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SHM access code</td>
</tr>
<tr>
<td align="center" valign="top">474</td>
<td align="center" valign="top">1DA</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Calling number</td>
</tr>
<tr>
<td align="center" valign="top">506</td>
<td align="center" valign="top">1FA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Station address</td>
</tr>
<tr>
<td align="center" valign="top">516</td>
<td align="center" valign="top">204</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Error threshold level</td>
</tr>
<tr>
<td align="center" valign="top">526</td>
<td align="center" valign="top">20E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Duplex</td>
</tr>
<tr>
<td align="center" valign="top">536</td>
<td align="center" valign="top">218</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modulus</td>
</tr>
<tr>
<td align="center" valign="top">546</td>
<td align="center" valign="top">222</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer type</td>
</tr>
<tr>
<td align="center" valign="top">556</td>
<td align="center" valign="top">22C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">566</td>
<td align="center" valign="top">236</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">576</td>
<td align="center" valign="top">240</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoconfigured for AS/36</td>
</tr>
<tr>
<td align="center" valign="top">586</td>
<td align="center" valign="top">24A</td>
<td align="left" valign="top">CHAR(60)</td>
<td align="left" valign="top">Modem initialization command</td>
</tr>
<tr>
<td align="center" valign="top">646</td>
<td align="center" valign="top">286</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">656</td>
<td align="center" valign="top">290</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">666</td>
<td align="center" valign="top">29A</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each resource name</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each call signal retry value</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Call progress signal retry value</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND9">LIND0900 Format</a></h3>
<p>This format returns detailed information about a line of category *TDLC.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached work station controller</td>
</tr>
<tr>
<td align="center" valign="top">126</td>
<td align="center" valign="top">7E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">146</td>
<td align="center" valign="top">92</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND10">LIND1000 Format</a></h3>
<p>This format returns detailed information about a line of category *TRN.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line speed</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Autodelete controller</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of function addresses</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of function addresses</td>
</tr>
<tr>
<td align="center" valign="top">192</td>
<td align="center" valign="top">C0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of function addresses</td>
</tr>
<tr>
<td align="center" valign="top">196</td>
<td align="center" valign="top">C4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">206</td>
<td align="center" valign="top">CE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">216</td>
<td align="center" valign="top">D8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">TRLAN manager logging level: configured</td>
</tr>
<tr>
<td align="center" valign="top">226</td>
<td align="center" valign="top">E2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">TRLAN manager logging level: current</td>
</tr>
<tr>
<td align="center" valign="top">236</td>
<td align="center" valign="top">EC</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">TRLAN manager mode</td>
</tr>
<tr>
<td align="center" valign="top">248</td>
<td align="center" valign="top">F8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Log configuration changes</td>
</tr>
<tr>
<td align="center" valign="top">258</td>
<td align="center" valign="top">102</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Token-ring inform of beacon</td>
</tr>
<tr>
<td align="center" valign="top">268</td>
<td align="center" valign="top">10C</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Local adapter address</td>
</tr>
<tr>
<td align="center" valign="top">280</td>
<td align="center" valign="top">118</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">290</td>
<td align="center" valign="top">122</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Early token release</td>
</tr>
<tr>
<td align="center" valign="top">300</td>
<td align="center" valign="top">12C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Error threshold level</td>
</tr>
<tr>
<td align="center" valign="top">310</td>
<td align="center" valign="top">136</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">320</td>
<td align="center" valign="top">140</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">330</td>
<td align="center" valign="top">14A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocreate controller</td>
</tr>
<tr>
<td align="center" valign="top">340</td>
<td align="center" valign="top">154</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Port number</td>
</tr>
<tr>
<td align="center" valign="top">344</td>
<td align="center" valign="top">158</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched NWI</td>
</tr>
<tr>
<td align="center" valign="top">354</td>
<td align="center" valign="top">162</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network interface DLC identifier</td>
</tr>
<tr>
<td align="center" valign="top">364</td>
<td align="center" valign="top">16C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network server description</td>
</tr>
<tr>
<td align="center" valign="top">374</td>
<td align="center" valign="top">176</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoconfigured for AS/36</td>
</tr>
<tr>
<td align="center" valign="top">384</td>
<td align="center" valign="top">180</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Duplex</td>
</tr>
<tr>
<td align="center" valign="top">394</td>
<td align="center" valign="top">18A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Activate LAN manager</td>
</tr>
<tr>
<td align="center" valign="top">404</td>
<td align="center" valign="top">194</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">LAN emulation client (LEC) cache aging time</td>
</tr>
<tr>
<td align="center" valign="top">408</td>
<td align="center" valign="top">198</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Address resolution protocol (ARP) retry
count</td>
</tr>
<tr>
<td align="center" valign="top">412</td>
<td align="center" valign="top">19C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Address resolution protocol (ARP) retry
timer</td>
</tr>
<tr>
<td align="center" valign="top">416</td>
<td align="center" valign="top">1A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">LAN emulation client (LEC) frame size</td>
</tr>
<tr>
<td align="center" valign="top">420</td>
<td align="center" valign="top">1A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum address resolution protocol (ARP)
entries</td>
</tr>
<tr>
<td align="center" valign="top">424</td>
<td align="center" valign="top">1A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">LAN emulation client (LEC) disconnect time
out</td>
</tr>
<tr>
<td align="center" valign="top">428</td>
<td align="center" valign="top">1AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of PVC identifiers</td>
</tr>
<tr>
<td align="center" valign="top">432</td>
<td align="center" valign="top">1B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of PVC identifiers</td>
</tr>
<tr>
<td align="center" valign="top">436</td>
<td align="center" valign="top">1B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of PVC identifiers</td>
</tr>
<tr>
<td align="center" valign="top">440</td>
<td align="center" valign="top">1B8</td>
<td align="left" valign="top">CHAR(13)</td>
<td align="left" valign="top">ATM access type</td>
</tr>
<tr>
<td align="center" valign="top">453</td>
<td align="center" valign="top">1C5</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Emulated LAN name</td>
</tr>
<tr>
<td align="center" valign="top">485</td>
<td align="center" valign="top">1E5</td>
<td align="left" valign="top">CHAR(26)</td>
<td align="left" valign="top">Local ATM address: network prefix</td>
</tr>
<tr>
<td align="center" valign="top">511</td>
<td align="center" valign="top">1FF</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Local ATM address: end-system-identifier</td>
</tr>
<tr>
<td align="center" valign="top">523</td>
<td align="center" valign="top">20B</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Local ATM address: LAN emulation client (LEC)
selector byte</td>
</tr>
<tr>
<td align="center" valign="top">525</td>
<td align="center" valign="top">20D</td>
<td align="left" valign="top">CHAR(26)</td>
<td align="left" valign="top">LAN emulation server (LES) ATM address: network
prefix</td>
</tr>
<tr>
<td align="center" valign="top">551</td>
<td align="center" valign="top">227</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">LAN emulation server (LES) ATM address: end
system identifier</td>
</tr>
<tr>
<td align="center" valign="top">563</td>
<td align="center" valign="top">233</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">LAN emulation server (LES) ATM address: selector
byte</td>
</tr>
<tr>
<td align="center" valign="top">565</td>
<td align="center" valign="top">235</td>
<td align="left" valign="top">CHAR(26)</td>
<td align="left" valign="top">Last contacted LAN emulation server (LES) ATM
address: network prefix</td>
</tr>
<tr>
<td align="center" valign="top">591</td>
<td align="center" valign="top">24F</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Last contacted LAN emulation server (LES) ATM
address: end system identifier</td>
</tr>
<tr>
<td align="center" valign="top">603</td>
<td align="center" valign="top">25B</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Last contacted LAN emulation server (LES) ATM
address: selector byte</td>
</tr>
<tr>
<td align="center" valign="top">605</td>
<td align="center" valign="top">25D</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Use LAN emulation configuration server (LECS)
address</td>
</tr>
<tr>
<td align="center" valign="top">615</td>
<td align="center" valign="top">267</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network interface type</td>
</tr>
<tr>
<td align="center" valign="top">625</td>
<td align="center" valign="top">271</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Reported emulated LAN name</td>
</tr>
<tr>
<td align="center" valign="top">657</td>
<td align="center" valign="top">291</td>
<td align="left" valign="top">CHAR(3)</td>
<td align="left" valign="top">Filler for alignment</td>
</tr>
<tr>
<td align="center" valign="top">660</td>
<td align="center" valign="top">294</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed multiplier</td>
</tr>
<tr>
<td align="center" valign="top">664</td>
<td align="center" valign="top">298</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">674</td>
<td align="center" valign="top">2A2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">684</td>
<td align="center" valign="top">2AC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">694</td>
<td align="center" valign="top">2B6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">704</td>
<td align="center" valign="top">2C0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Current line speed</td>
</tr>
<tr>
<td align="center" valign="top">708</td>
<td align="center" valign="top">2C4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current duplex</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="3">These fields repeat for
each SSAP</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SSAP maximum frame</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP address</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP type</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2">This field repeats for each function
address</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Function address</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2">This field repeats for each PVC
identifier</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">PVC identifier</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND11">LIND1100 Format</a></h3>
<p>This format returns detailed information about a line of category *X25.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line speed</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Default packet size: transmit</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Default packet size: receive</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum packet size: transmit</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum packet size: receive</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Default window size: transmit</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Default window size: receive</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Idle timer</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Frame retry</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Predial delay</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Redial delay</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Dial retries</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Switched disconnect timers: minimum
connection</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Switched disconnect timers: disconnect delay</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Data Set Ready drop timer</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Clear To Send timer</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Remote answer timer</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">192</td>
<td align="center" valign="top">C0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">196</td>
<td align="center" valign="top">C4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">200</td>
<td align="center" valign="top">C8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">204</td>
<td align="center" valign="top">CC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">208</td>
<td align="center" valign="top">D0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">212</td>
<td align="center" valign="top">D4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">216</td>
<td align="center" valign="top">D8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">220</td>
<td align="center" valign="top">DC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">224</td>
<td align="center" valign="top">E0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">228</td>
<td align="center" valign="top">E4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">232</td>
<td align="center" valign="top">E8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">236</td>
<td align="center" valign="top">EC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">240</td>
<td align="center" valign="top">F0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of logical channel entries</td>
</tr>
<tr>
<td align="center" valign="top">244</td>
<td align="center" valign="top">F4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of logical channel entries</td>
</tr>
<tr>
<td align="center" valign="top">248</td>
<td align="center" valign="top">F8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of logical channel
entries</td>
</tr>
<tr>
<td align="center" valign="top">252</td>
<td align="center" valign="top">FC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">256</td>
<td align="center" valign="top">100</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">260</td>
<td align="center" valign="top">104</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">264</td>
<td align="center" valign="top">108</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">274</td>
<td align="center" valign="top">112</td>
<td align="left" valign="top">CHAR(20)</td>
<td align="left" valign="top">Local network address</td>
</tr>
<tr>
<td align="center" valign="top">294</td>
<td align="center" valign="top">126</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection initiation</td>
</tr>
<tr>
<td align="center" valign="top">304</td>
<td align="center" valign="top">130</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Physical interface</td>
</tr>
<tr>
<td align="center" valign="top">314</td>
<td align="center" valign="top">13A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection type</td>
</tr>
<tr>
<td align="center" valign="top">324</td>
<td align="center" valign="top">144</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched NWI</td>
</tr>
<tr>
<td align="center" valign="top">334</td>
<td align="center" valign="top">14E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel type</td>
</tr>
<tr>
<td align="center" valign="top">344</td>
<td align="center" valign="top">158</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel number</td>
</tr>
<tr>
<td align="center" valign="top">354</td>
<td align="center" valign="top">162</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">X.25 DCE support</td>
</tr>
<tr>
<td align="center" valign="top">364</td>
<td align="center" valign="top">16C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">374</td>
<td align="center" valign="top">176</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">384</td>
<td align="center" valign="top">180</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Packet mode</td>
</tr>
<tr>
<td align="center" valign="top">394</td>
<td align="center" valign="top">18A</td>
<td align="left" valign="top">CHAR(13)</td>
<td align="left" valign="top">Information transfer type</td>
</tr>
<tr>
<td align="center" valign="top">407</td>
<td align="center" valign="top">197</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Extended network addressing</td>
</tr>
<tr>
<td align="center" valign="top">417</td>
<td align="center" valign="top">1A1</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modulus</td>
</tr>
<tr>
<td align="center" valign="top">427</td>
<td align="center" valign="top">1AB</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Insert network address in packets</td>
</tr>
<tr>
<td align="center" valign="top">437</td>
<td align="center" valign="top">1B5</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Error threshold level</td>
</tr>
<tr>
<td align="center" valign="top">447</td>
<td align="center" valign="top">1BF</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Connection number</td>
</tr>
<tr>
<td align="center" valign="top">479</td>
<td align="center" valign="top">1DF</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Calling number</td>
</tr>
<tr>
<td align="center" valign="top">511</td>
<td align="center" valign="top">1FF</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem type supported</td>
</tr>
<tr>
<td align="center" valign="top">521</td>
<td align="center" valign="top">209</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Modem data rate select</td>
</tr>
<tr>
<td align="center" valign="top">531</td>
<td align="center" valign="top">213</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched connection type</td>
</tr>
<tr>
<td align="center" valign="top">541</td>
<td align="center" valign="top">21D</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Outgoing connection list</td>
</tr>
<tr>
<td align="center" valign="top">551</td>
<td align="center" valign="top">227</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Outgoing connection list entry</td>
</tr>
<tr>
<td align="center" valign="top">561</td>
<td align="center" valign="top">231</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Incoming connection list</td>
</tr>
<tr>
<td align="center" valign="top">571</td>
<td align="center" valign="top">23B</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer</td>
</tr>
<tr>
<td align="center" valign="top">581</td>
<td align="center" valign="top">245</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autodial</td>
</tr>
<tr>
<td align="center" valign="top">591</td>
<td align="center" valign="top">24F</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Dial command type</td>
</tr>
<tr>
<td align="center" valign="top">601</td>
<td align="center" valign="top">259</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Call immediate</td>
</tr>
<tr>
<td align="center" valign="top">611</td>
<td align="center" valign="top">263</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall unit</td>
</tr>
<tr>
<td align="center" valign="top">621</td>
<td align="center" valign="top">26D</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocall resource name</td>
</tr>
<tr>
<td align="center" valign="top">631</td>
<td align="center" valign="top">277</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched disconnect</td>
</tr>
<tr>
<td align="center" valign="top">641</td>
<td align="center" valign="top">281</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoanswer type</td>
</tr>
<tr>
<td align="center" valign="top">651</td>
<td align="center" valign="top">28B</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched NWI selection</td>
</tr>
<tr>
<td align="center" valign="top">661</td>
<td align="center" valign="top">295</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">671</td>
<td align="center" valign="top">29F</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">681</td>
<td align="center" valign="top">2A9</td>
<td align="left" valign="top">CHAR(214)</td>
<td align="left" valign="top">Network user identification facility</td>
</tr>
<tr>
<td align="center" valign="top">896</td>
<td align="center" valign="top">380</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Clocking</td>
</tr>
<tr>
<td align="center" valign="top">906</td>
<td align="center" valign="top">38A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autoconfigured for AS/36</td>
</tr>
<tr>
<td align="center" valign="top">916</td>
<td align="center" valign="top">394</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">926</td>
<td align="center" valign="top">39E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">936</td>
<td align="center" valign="top">3A8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">946</td>
<td align="center" valign="top">3B2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">956</td>
<td align="center" valign="top">3BC</td>
<td align="left" valign="top">CHAR(60)</td>
<td align="left" valign="top">Modem initialization command</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="4">These fields repeat for
each logical channel entry</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Logical channel identifier</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Logical channel type</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Logical channel controller</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="4">These fields repeat for
each switched NWI</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel number</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel type</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND12">LIND1200 Format</a></h3>
<p>This format returns detailed information about a line of category *DDI.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Token rotation time</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Autodelete controller</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">192</td>
<td align="center" valign="top">C0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">196</td>
<td align="center" valign="top">C4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">206</td>
<td align="center" valign="top">CE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI name</td>
</tr>
<tr>
<td align="center" valign="top">216</td>
<td align="center" valign="top">D8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network interface DLC identifier</td>
</tr>
<tr>
<td align="center" valign="top">226</td>
<td align="center" valign="top">E2</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Local adapter address</td>
</tr>
<tr>
<td align="center" valign="top">238</td>
<td align="center" valign="top">EE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">248</td>
<td align="center" valign="top">F8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attach mode</td>
</tr>
<tr>
<td align="center" valign="top">258</td>
<td align="center" valign="top">102</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">268</td>
<td align="center" valign="top">10C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">278</td>
<td align="center" valign="top">116</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocreate controller</td>
</tr>
<tr>
<td align="center" valign="top">288</td>
<td align="center" valign="top">120</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Logging level</td>
</tr>
<tr>
<td align="center" valign="top">298</td>
<td align="center" valign="top">12A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Local manager mode</td>
</tr>
<tr>
<td align="center" valign="top">308</td>
<td align="center" valign="top">134</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">318</td>
<td align="center" valign="top">13E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">328</td>
<td align="center" valign="top">148</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">338</td>
<td align="center" valign="top">152</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">348</td>
<td align="center" valign="top">15C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">358</td>
<td align="center" valign="top">166</td>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="3">These fields repeat for
each SSAP</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SSAP maximum frame</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP address</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP type</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2">This field repeats for each group
address</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Group address</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND13">LIND1300 Format</a></h3>
<p>This format returns detailed information about a line of category *FR.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched NWI</td>
</tr>
<tr>
<td align="center" valign="top">186</td>
<td align="center" valign="top">BA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network interface DLC identifier</td>
</tr>
<tr>
<td align="center" valign="top">196</td>
<td align="center" valign="top">C4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">206</td>
<td align="center" valign="top">CE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">216</td>
<td align="center" valign="top">D8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">226</td>
<td align="center" valign="top">E2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">236</td>
<td align="center" valign="top">EC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">246</td>
<td align="center" valign="top">F6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">256</td>
<td align="center" valign="top">100</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">266</td>
<td align="center" valign="top">10A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each active switched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="3">These fields repeat for
each SSAP</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SSAP maximum frame</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP address</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP type</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND14">LIND1400 Format</a></h3>
<p>This format returns detailed information about a line of category *FAX.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of attached nonswitched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of resource names</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of resource names</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of resource names</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">142</td>
<td align="center" valign="top">8E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each nonswitched controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each resource name</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND15">LIND1500 Format</a></h3>
<p>This format returns detailed information about a line of category *WLS.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum controllers</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link speed</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per connect time</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Cost per byte</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 1</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 2</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">User-defined 3</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Autodelete controller</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of active switched controllers</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of active switched
controllers</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">168</td>
<td align="center" valign="top">A8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">172</td>
<td align="center" valign="top">AC</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of SSAPs</td>
</tr>
<tr>
<td align="center" valign="top">176</td>
<td align="center" valign="top">B0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">180</td>
<td align="center" valign="top">B4</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of group addresses</td>
</tr>
<tr>
<td align="center" valign="top">188</td>
<td align="center" valign="top">BC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">198</td>
<td align="center" valign="top">C6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">208</td>
<td align="center" valign="top">D0</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Local adapter address</td>
</tr>
<tr>
<td align="center" valign="top">220</td>
<td align="center" valign="top">DC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Exchange identifier</td>
</tr>
<tr>
<td align="center" valign="top">230</td>
<td align="center" valign="top">E6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Ethernet standard</td>
</tr>
<tr>
<td align="center" valign="top">240</td>
<td align="center" valign="top">F0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Security for line</td>
</tr>
<tr>
<td align="center" valign="top">250</td>
<td align="center" valign="top">FA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Propagation delay</td>
</tr>
<tr>
<td align="center" valign="top">260</td>
<td align="center" valign="top">104</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Autocreate controller</td>
</tr>
<tr>
<td align="center" valign="top">270</td>
<td align="center" valign="top">10E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Initialization source file name</td>
</tr>
<tr>
<td align="center" valign="top">280</td>
<td align="center" valign="top">118</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Initialization source file library name</td>
</tr>
<tr>
<td align="center" valign="top">290</td>
<td align="center" valign="top">122</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Initialization source member name</td>
</tr>
<tr>
<td align="center" valign="top">300</td>
<td align="center" valign="top">12C</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Initialization program name</td>
</tr>
<tr>
<td align="center" valign="top">310</td>
<td align="center" valign="top">136</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Initialization program library name</td>
</tr>
<tr>
<td align="center" valign="top">320</td>
<td align="center" valign="top">140</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">330</td>
<td align="center" valign="top">14A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="2">These fields repeat for
each controller</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Active switched controller name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="3">These fields repeat for
each SSAP</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">SSAP maximum frame</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP address</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">SSAP type</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2">This field repeats for each group
address</td>
<td align="left" valign="top">CHAR(12)</td>
<td align="left" valign="top">Group address</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLIND16">LIND1600 Format</a></h3>
<p>This format returns detailed information about a line of category *PPP.</p>
<table border width="80%">
<tr>
<th align="center" valign="bottom" colspan="2">Offset</th>
<th align="left" valign="bottom" rowspan="2">Type</th>
<th align="left" valign="bottom" rowspan="2">Field</th>
</tr>
<tr>
<th align="center" valign="bottom">Dec</th>
<th align="center" valign="bottom">Hex</th>
</tr>
<tr>
<td align="center" valign="top" width="10%">0</td>
<td align="center" valign="top" width="10%">0</td>
<td align="left" valign="top" width="20%">&nbsp;</td>
<td align="left" valign="top" width="60%">Returns everything from format
LIND0100</td>
</tr>
<tr>
<td align="center" valign="top">108</td>
<td align="center" valign="top">6C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Vary on wait</td>
</tr>
<tr>
<td align="center" valign="top">112</td>
<td align="center" valign="top">70</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Line speed</td>
</tr>
<tr>
<td align="center" valign="top">116</td>
<td align="center" valign="top">74</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Maximum frame size</td>
</tr>
<tr>
<td align="center" valign="top">120</td>
<td align="center" valign="top">78</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Inactivity Timer</td>
</tr>
<tr>
<td align="center" valign="top">124</td>
<td align="center" valign="top">7C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Remote answer timer</td>
</tr>
<tr>
<td align="center" valign="top">128</td>
<td align="center" valign="top">80</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Clear to send timer</td>
</tr>
<tr>
<td align="center" valign="top">132</td>
<td align="center" valign="top">84</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: count limit</td>
</tr>
<tr>
<td align="center" valign="top">136</td>
<td align="center" valign="top">88</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Recovery limits: time interval</td>
</tr>
<tr>
<td align="center" valign="top">140</td>
<td align="center" valign="top">8C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link control protocol authentication values:
remote peer challenge timer</td>
</tr>
<tr>
<td align="center" valign="top">144</td>
<td align="center" valign="top">90</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link control protocol authentication values:
maximum authentication attempts</td>
</tr>
<tr>
<td align="center" valign="top">148</td>
<td align="center" valign="top">94</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link control protocol configuration values:
configuration retry timer</td>
</tr>
<tr>
<td align="center" valign="top">152</td>
<td align="center" valign="top">98</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link control protocol configuration values:
maximum configuration failures</td>
</tr>
<tr>
<td align="center" valign="top">156</td>
<td align="center" valign="top">9C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link control protocol configuration values:
maximum configuration requests</td>
</tr>
<tr>
<td align="center" valign="top">160</td>
<td align="center" valign="top">A0</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Link control protocol configuration values:
maximum termination requests</td>
</tr>
<tr>
<td align="center" valign="top">164</td>
<td align="center" valign="top">A4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Link control protocol configuration values:
configuration retry timer</td>
</tr>
<tr>
<td align="center" valign="top">174</td>
<td align="center" valign="top">AE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Async control character map</td>
</tr>
<tr>
<td align="center" valign="top">184</td>
<td align="center" valign="top">B8</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Resource name</td>
</tr>
<tr>
<td align="center" valign="top">194</td>
<td align="center" valign="top">C2</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Physical interface</td>
</tr>
<tr>
<td align="center" valign="top">204</td>
<td align="center" valign="top">CC</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Framing type</td>
</tr>
<tr>
<td align="center" valign="top">214</td>
<td align="center" valign="top">D6</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Connection type</td>
</tr>
<tr>
<td align="center" valign="top">224</td>
<td align="center" valign="top">E0</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Network controller</td>
</tr>
<tr>
<td align="center" valign="top">234</td>
<td align="center" valign="top">EA</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NRZI</td>
</tr>
<tr>
<td align="center" valign="top">244</td>
<td align="center" valign="top">F4</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched connection type</td>
</tr>
<tr>
<td align="center" valign="top">254</td>
<td align="center" valign="top">FE</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Clocking</td>
</tr>
<tr>
<td align="center" valign="top">264</td>
<td align="center" valign="top">108</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Dial command type</td>
</tr>
<tr>
<td align="center" valign="top">274</td>
<td align="center" valign="top">112</td>
<td align="left" valign="top">CHAR(40)</td>
<td align="left" valign="top">Set modem to ASYNC command</td>
</tr>
<tr>
<td align="center" valign="top">314</td>
<td align="center" valign="top">13A</td>
<td align="left" valign="top">CHAR(32)</td>
<td align="left" valign="top">Calling number</td>
</tr>
<tr>
<td align="center" valign="top">346</td>
<td align="center" valign="top">15A</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Flow control</td>
</tr>
<tr>
<td align="center" valign="top">356</td>
<td align="center" valign="top">164</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Attached nonswitched NWI</td>
</tr>
<tr>
<td align="center" valign="top">366</td>
<td align="center" valign="top">16E</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel number</td>
</tr>
<tr>
<td align="center" valign="top">376</td>
<td align="center" valign="top">178</td>
<td align="left" valign="top">CHAR(13)</td>
<td align="left" valign="top">Information transfer type</td>
</tr>
<tr>
<td align="center" valign="top">389</td>
<td align="center" valign="top">185</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Outgoing connection list</td>
</tr>
<tr>
<td align="center" valign="top">399</td>
<td align="center" valign="top">18F</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Outgoing connection list entry</td>
</tr>
<tr>
<td align="center" valign="top">409</td>
<td align="center" valign="top">199</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Incoming connection list</td>
</tr>
<tr>
<td align="center" valign="top">419</td>
<td align="center" valign="top">1A3</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Switched NWI selection</td>
</tr>
<tr>
<td align="center" valign="top">429</td>
<td align="center" valign="top">1AD</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Compression</td>
</tr>
<tr>
<td align="center" valign="top">439</td>
<td align="center" valign="top">1B7</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">449</td>
<td align="center" valign="top">1C1</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">459</td>
<td align="center" valign="top">1CB</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: name</td>
</tr>
<tr>
<td align="center" valign="top">469</td>
<td align="center" valign="top">1D5</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">Current message queue: library</td>
</tr>
<tr>
<td align="center" valign="top">479</td>
<td align="center" valign="top">1DF</td>
<td align="left" valign="top">CHAR(60)</td>
<td align="left" valign="top">Modem init command string</td>
</tr>
<tr>
<td align="center" valign="top">539</td>
<td align="center" valign="top">21B</td>
<td align="left" valign="top">CHAR(1)</td>
<td align="left" valign="top">Reserved</td>
</tr>
<tr>
<td align="center" valign="top">540</td>
<td align="center" valign="top">21C</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Offset to list of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">544</td>
<td align="center" valign="top">220</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Number of switched NWIs</td>
</tr>
<tr>
<td align="center" valign="top">548</td>
<td align="center" valign="top">224</td>
<td align="left" valign="top">BINARY(4)</td>
<td align="left" valign="top">Entry length for list of switched NWIs</td>
</tr>
<tr>
<td align="left" valign="top" colspan="2" rowspan="4">These fields repeat for
each switched NWI</td>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI name</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel type</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(10)</td>
<td align="left" valign="top">NWI channel number</td>
</tr>
<tr>
<td align="left" valign="top">CHAR(2)</td>
<td align="left" valign="top">Reserved</td>
</tr>
</table>
<br>
<br>
<h3><a name="HDRLINDFLD">Field Descriptions</a></h3>
<p>Some of the fields in the various formats returned by this API are described
in greater detail in the <a href="../clfinder/name_finder.htm">Control
Language (CL)</a> information for the particular command that was used to
create the line description object. They are also described in the online help
for the particular command. For these fields, the CL parameter keyword is
specified in parentheses following the field name. The CL command name is
specified in the field description.</p>
<p>In certain cases, numeric values are assigned by this API to represent
character values for some of the returned fields. Where a numeric value is
assigned, the numeric value and the equivalent character value are listed as an
<em>Exception</em> in the following field descriptions.</p>
<p><strong>Activate LAN manager (ACTLANMGR).</strong> Whether the LAN manager
support is activated. (See the ACTLANMGR parameter in the Control Language (CL)
information for the <a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Activate switched network backup.</strong> Whether the switched
network backup is activated.</p>
<p><strong>Active switched controller name.</strong> The name of a controller
associated with this line.</p>
<p><strong>Application type (APPTYPE).</strong> The type of application that
this BSC line is used for. (See the APPTYPE parameter in the Control Language
(CL) information for the <a href="../cl/crtlinbsc.htm">CRTLINBSC</a>
command.)</p>
<p><strong>ARP retry count.</strong> The number of times an address resolution
protocol (ARP) request will be retried if no response is received.</p>
<p><strong>ARP retry timer</strong> The amount of time to wait for a response
to an address resolution protocol (ARP) request.</p>
<p><strong>Associated port resource name (ASSOCPORT).</strong> Specifies the resource name that describes the port that is used to establish a connection between a Windows network server and the network. (See the ASSOCPORT parameter in the Control Language (CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> command.)</p>
<p><strong>Async control character map.</strong> Control characters that either
may not be successfully received over an asynchronous serial line or which may
be spuriously introduced by other data communications equipment into a
transmission on the line.</p>
<p><strong>Attach mode.</strong> The attach mode specified when the line was
created. The term attach mode means the same thing as station type.</p>
<p><strong>Attached nonswitched controller name.</strong> The name of a
controller associated with this line.</p>
<p><strong>Attached nonswitched network interface (NWI).</strong> The name of
the nonswitched network interface (NWI) description that contains the channel
to which this line is to be attached. (See the NWI parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Attached workstation controller (WSC).</strong> The name of the
controller description for the 5394 work station controller or the work station
controller to which the personal computer is attached. (See the WSC parameter
in the Control Language (CL) information for the
<a href="../cl/crtlintdlc.htm">CRTLINTDLC</a> command.)</p>
<p><strong>ATM access type (ACCTYPE).</strong> The type of access to the ATM
network. (See the ACCTYPE parameter in the Control Language (CL) information for
the <a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Autoanswer (AUTOANS).</strong> Whether you intend to use your
modem's automatic answer function. (See the AUTOANS parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Autoanswer type (AUTOANSTYP).</strong> The method to be used by the
system and modem to answer incoming calls. (See the AUTOANSTYP parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Autocall resource name (ACRSRCNAME).</strong> The name that is
assigned by the system to a communications port from which a communications
line attaches to an automatic call unit. (See the ACRSRCNAME parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Autocall unit (AUTOCALL).</strong> An associated automatic call
unit. (See the AUTOCALL parameter in the Control Language (CL) information for
the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Autoconfigured for AS/36.</strong> The line was automatically
configured for AS/36.</p>
<p><strong>Autocreate controller (AUTOCRTCTL).</strong> Whether the system is
to automatically create APPC controller descriptions when incoming calls are
received from other systems on the local area network. (See the AUTOCRTCTL
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinwls.htm">CRTLINWLS</a> command.)</p>
<p><strong>Autodelete controller (AUTODLTCTL).</strong> The number of minutes
the system should wait before automatically varying off and deleting
automatically created controller descriptions associated with this line. (See
the AUTODLTCTL parameter in the Control Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinwls.htm">CRTLINWLS</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -3 means *NONE</li>
</ul>
<p><strong>Autodial (AUTODIAL).</strong> Whether or not you intend to use the
automatic call function to dial the remote system or network to establish a
switched line connection. (See the AUTODIAL parameter in the Control Language
(CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Call immediate (CALLIMMED).</strong> For switched X.25 lines,
whether a call should be made immediately after varying on the line
description. (See the CALLIMMED parameter in the Control Language (CL)
information for the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Calling number (CALLNBR).</strong> The local connection number of a
line. (See the CALLNBR parameter in the Control Language (CL) information for
the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Call progress signal retry value (CPSRTY).</strong> Whether a call
attempt should be retried if the specified call progress signal is received.
(See the CPSRTY parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Character code (CODE).</strong> The type of character code used.
(See the CODE parameter in the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Clear to send timer (CTSTMR).</strong> The length of time that the
system should wait for the modem (DCE) to raise or drop Clear to Send (CTS)
before signaling an error. (See the CTSTMR parameter in the Control Language
(CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>Clocking (CLOCK).</strong> The clocking function for the line is
provided by the modem (*MODEM). (See the CLOCK parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Compression (COMPRESS).</strong> The compression function is
provided. (See the COMPRESS parameter in the Control Language (CL) information
for the <a href="../cl/crtlinppp.htm">CRTLINPPP</a> command.)</p>
<p><strong>Connection initiation (CNNINIT).</strong> The values to initiate the
X.25 data link connection. (See the CNNINIT parameter in the Control Language
(CL) information for the <a href="../cl/crtlinx25.htm">CRTLINX25</a>
command.)</p>
<p><strong>Connection list (CNNLSTIN).</strong> The name of the connection list
used to retrieve ISDN call information when authorizing incoming calls. (See
the CNNLSTIN parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Connection number (CNNNBR).</strong> For switched X.25 lines, the
number of the remote DCE (packet switched data network) that can be contacted
using this line description. (See the CNNNBR parameter in the Control Language
(CL) information for the <a href="../cl/crtlinx25.htm">CRTLINX25</a>
command.)</p>
<p><strong>Connect poll retry (CNNPOLLRTY).</strong> The number of connect poll
retries that will be attempted before the system indicates an error in
contacting the remote system or controller. (See the CNNPOLLRTY parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Connect poll timer (CNNPOLLTMR).</strong> The length of time that
the system waits for the response to a poll while in normal disconnect mode
before polling the next station. (See the CNNPOLLTMR parameter in the Control
Language (CL) information for the <a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>
command.)</p>
<p><strong>Connect retry count (IDLCCNNRTY).</strong> The number of times to
retry a transmission at connection time. (See the IDLCCNNRTY parameter in the
Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
<li>Value of -9 means *CNN</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Connect timer (CNNTMR).</strong> The amount of time that an
automatic answer connect request waits for an incoming call on an X.21
circuit-switched line. (See the CNNTMR parameter in the Control Language (CL)
information for the <a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>Connection type (CNN).</strong> The type of line connection. (See
the CNN parameter in the Control Language (CL) information for the
<a href=
"../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Contention state retry (CTNRTY).</strong> The number of contention
state retries that can be attempted before disconnecting the line. (See the
CTNRTY parameter in the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Continue timer (CONTTMR).</strong> The length of time that the
system waits before sending a TTD or WACK control character. (See the CONTTMR
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Controller category.</strong> This value will be one of the
following:</p>
<dl>
<dd>*APPC</dd>
<dd>*ASC</dd>
<dd>*BSC</dd>
<dd>*FNC</dd>
<dd>*HOST</dd>
<dd>*LWS</dd>
<dd>*NET</dd>
<dd>*RTL</dd>
<dd>*RWS</dd>
<dd>*VWS</dd>
<dd>*TAP</dd>
</dl>
<p>The category value is derived from the command used to create the controller
description.</p>
<p><strong>Controller name (CTL).</strong> The names of one or more controller
descriptions associated with this line. (See the CTL parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinfax.htm">CRTLINFAX</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlintdlc.htm">CRTLINTDLC</a> command.)</p>
<p><strong>Controller text description.</strong> A brief description of a
controller associated with this line.</p>
<p><strong>Controller type.</strong> The type of controller being described.
(See the TYPE parameter in the Control Language (CL) information for the
<a href="../cl/crtctlappc.htm">CRTCTLAPPC</a>,
<a href="../cl/crtctlfnc.htm">CRTCTLFNC</a>,
<a href="../cl/crtctllws.htm">CRTCTLLWS</a>,
<a href="../cl/crtctlrtl.htm">CRTCTLRTL</a>,
<a href="../cl/crtctlrws.htm">CRTCTLRWS</a>, or
<a href="../cl/crtctltap.htm">CRTCTLTAP</a> command.)</p>
<p><strong>Cost per byte (COSTBYTE).</strong> The relative cost per byte of
sending and receiving data on the line. (See the COSTBYTE parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -9 means *CNN</li>
</ul>
<p><strong>Cost per connect time (COSTCNN).</strong> The relative cost of being
connected on the line. (See the COSTCNN parameter in the Control Language (CL)
information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -9 means *CNN</li>
</ul>
<p><strong>CRC errors received (CRCRCV).</strong> The level of error threshold
monitoring done by the system for CRC errors received. (See the CRCRCV
parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -4 means *OFF</li>
<li>Value of -5 means *MIN</li>
<li>Value of -6 means *MED</li>
<li>Value of -7 means *MAX</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong> Current duplex (DUPLEX).</strong> The actual duplex mode being used
by the hardware associated with the line description. The current duplex value
with *AUTO is determined by the hardware. (See the DUPLEX parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Note:</strong> *AUTO is valid until the line is varied on. After the
line is varied on, *AUTO is resolved to either *HALF or *FULL.</p>
<p><strong> Current line speed (LINESPEED).</strong> The actual speed of the
line description. This value is determined by the hardware. (See the LINESPEED
parameter in the Control Language (CL) information for the
<a href=
"../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -11 means *CALC</li>
<li>Value of -23 means 10M</li>
<li>Value of -24 means 4M</li>
<li>Value of -25 means 16M</li>
<li>Value of -27 means *NWI</li>
<li>Value of -29 means 100M</li>
<li>Value of -30 means *AUTO</li>
<li>Value of -34 means 1G</li>
<img src="delta.gif" alt="Start of change">
<li>Value of -35 means 10G</li>
<img src="deltaend.gif" alt="End of change">
</ul>
<p><strong>Note:</strong> The values *CALC, *NWI, and *AUTO can be returned
only when the line is varied off. If the line is varied on, these values will
be resolved to a discrete line speed.</p>
<p><strong>Current message queue (MSGQ).</strong> The message queue to which
messages are currently being sent using this line description. This field is
valid only for lines that are varied on. Note that the value of the current
message queue may be different from the message queue field (MSGQ parameter)
under certain error conditions. (See the MSGQ parameter in the Control Language
(CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)
This information is returned in two separate fields:</p>
<ul>
<li><em>Name</em> of the queue</li>
<li><em>Library</em> in which the queue can be found</li>
</ul>
<p><strong>Data bits per character (BITSCHAR).</strong> The data bits per
character (either 7 or 8 bits excluding the parity bit). (See the BITSCHAR
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a> command.)</p>
<p><strong>Data link role (ROLE).</strong> Whether this system is the primary
station or secondary station, or if this station should dynamically negotiate
its role with the remote station when the line is varied on. (See the ROLE
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Data set ready drop timer (DSRDRPTMR).</strong> The length of time
that the system should wait for the modem (DCE) to drop Data Set Ready (DSR)
after the system has dropped Data Terminal Ready (DTR) before signalling an
error. (See the DSRDRPTMR parameter in the Control Language (CL) information
for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Data state retry (DTASTTRTY).</strong> The time before retry when
BSC is sending or receiving data on the communications line. (See the DTASTTRTY
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Date information retrieved.</strong> The date that the information
was provided by the API. This is returned as 7 characters in the form CYYMMDD,
as follows:</p>
<table cellpadding="5">
<!-- cols="15 85" -->
<tr>
<td align="left" valign="top"><em>C</em></td>
<td align="left" valign="top">Century, where 0 indicates years 19<em>xx</em>
and 1 indicates years 20<em>xx</em>.</td>
</tr>
<tr>
<td align="left" valign="top"><em>YY</em></td>
<td align="left" valign="top">Year</td>
</tr>
<tr>
<td align="left" valign="top"><em>MM</em></td>
<td align="left" valign="top">Month</td>
</tr>
<tr>
<td align="left" valign="top"><em>DD</em></td>
<td align="left" valign="top">Day</td>
</tr>
</table>
<p><strong>Default packet size (DFTPKTSIZE).</strong> The default packet size
to use for controllers attached to this line description. This information is
returned in two separate fields:</p>
<ul>
<li><em>Transmit</em></li>
<li><em>Receive</em></li>
</ul>
<p>(See the DFTPKTSIZE parameter in the Control Language (CL) information for
the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -10 means *TRANSMIT</li>
</ul>
<p><strong>Default window size: transmit/receive (IDLCWDWSIZ,
DFTWDWSIZE)</strong> The default window size used for this line description.
(See the DFTWDWSIZE parameter in the Control Language (CL) information for the
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -9 means *CNN</li>
<li>Value of -10 means *TRANSMIT</li>
</ul>
<p><strong>Dial command type (DIALCMD).</strong> The dial command type used to
establish a connection with a remote system. (See the DIALCMD parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Dial retries (DIALRTY).</strong> The number of times to retry
dialing the number before considering the dialing unsuccessful. (See the
DIALRTY parameter in the Control Language (CL) information for the
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Duplex (DUPLEX).</strong></p>
<ul>
<li><em>WAN (Async, SDLC, or Bisync)</em>: Whether the system will leave the
request-to-send (RTS) modem signal on continuously, or whether the RTS will be
raised when the system must transmit data and dropped when it is finished
transmitting.</li>
<li><em>LAN (Ethernet or Token-Ring)</em>: Whether the hardware is able to send
and receive data simultaneously. In half duplex, one wire must alternate
between sending and receiving. With duplex, one wire is dedicated to send and
another to receive, and hence simultaneous send and receive operations may
occur. With full duplex, a hub is required. With *AUTO, the duplex value will
be determined by the hardware.</li>
</ul>
<p>(See the DUPLEX parameter in the Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Early token release (ELYTKNRLS).</strong> Allows greater throughput
on 16MB token-ring network lines. (See the ELYTKNRLS parameter in the Control
Language (CL) information for the <a href="../cl/crtlintrn.htm">CRTLINTRN</a>
command.)</p>
<p><strong>Echo support (ECHO).</strong> Whether the system is to send back
(echo) to the remote station none of the characters that it receives, all of
the characters it receives, or all data up to, but not including, the
end-of-record character (*CNTL). (See the ECHO parameter in the Control
Language (CL) information for the <a href="../cl/crtlinasc.htm">CRTLINASC</a>
command.)</p>
<p><strong>Emulated LAN name (EMLLANNAME).</strong> Specifies the emulated LAN
name. (See the EMLLANNAME parameter in the Control Language (CL) information
for the <a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong> Enable for TCP/IP (TCPONLY).</strong> Whether you want the line
description to be used for TCP/IP only.</p>
<p><strong>Note:</strong> TCPONLY is not used after release V4R5. The field
will contain blanks.</p>
<p><strong>Entry length for list of active switched controllers.</strong> The
entry length in bytes of each element in the list of active switched
controllers returned with this format. A value of zero is returned if the list
is empty.</p>
<p><strong>Entry length for list of attached nonswitched controllers.</strong>
The entry length in bytes of each element in the list of attached nonswitched
controllers returned with this format. A value of zero is returned if the list
is empty.</p>
<p><strong>Entry length for list of call progress signal retry values.</strong>
The entry length in bytes of each element in the list of call progress signal
retry values returned with this format. A value of zero is returned if the list
is empty.</p>
<p><strong>Entry length for list of EOR characters.</strong> The entry length
in bytes of each element in the list of end-of-record (EOR) characters returned
with this format. A value of zero is returned if the list is empty.</p>
<p><strong>Entry length for list of function addresses.</strong> The entry
length in bytes of each element in the list of function addresses returned with
this format. A value of zero is returned if the list is empty.</p>
<p><strong>Entry length for list of group addresses.</strong> The entry length
in bytes of each element in the list of group addresses returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Entry length for list of logical channel entries.</strong> The entry
length in bytes of each element in the list of logical channel entries returned
with this format. A value of zero is returned if the list is empty.</p>
<p><strong>Entry length for list of PVC identifiers.</strong> The entry length
in bytes of each element in the list of permanent virtual circuits (PVC)
returned with this format. A value of zero is returned if the list is
empty.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Entry length for list of resource names.</strong> The entry length
in bytes of each element in the list of resource names returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Entry length for list of SSAPs.</strong> The entry length in bytes
of each element in the list of SSAPs returned with this format. A value of zero
is returned if the list is empty.</p>
<p><strong>Entry length for list of switched controllers.</strong> The entry
length in bytes of each element in the list of switched controllers returned
with this format. A value of zero is returned if the list is empty.</p>
<p><strong>Entry length for list of switched NWIs.</strong> The entry length in
bytes of each element in the list of switched network interface (NWI)
descriptions returned with this format. A value of zero is returned if the list
is empty.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>EOR character.</strong> The end-of-record character.</p>
<p><strong>Error threshold level (THRESHOLD).</strong> The level of the error
threshold that is monitored by the system. (See the THRESHOLD parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Ethernet standard (ETHSTD).</strong> The standard used by the
Ethernet local area network. (See the ETHSTD parameter in the Control Language
(CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlinwls.htm">CRTLINWLS</a> command.)</p>
<p><strong>Exchange identifier (EXCHID).</strong> The exchange identifier that
the local system can send to the remote controller or system. (See the EXCHID
parameter in the Control Language (CL) information for the
<a href=
"../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Extended network addressing (EXNNETADR).</strong> Whether extended
network addressing is used by this line description and attached controller
descriptions. (See the EXNNETADR parameter in the Control Language (CL)
information for the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Fair polling timer (FAIRPLLTMR).</strong> The maximum length of time
(in seconds) that the system will send data to one or more stations on the line
before polling stations without pending output requests. (See the FAIRPLLTMR
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Flow control (FLOWCNTL).</strong> Whether you will use the XON and
XOFF flow control characters to control the flow of data to your system. (See
the FLOWCNTL parameter in the Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a> or
<a href="../cl/crtlinppp.htm">CRTLINPPP</a> command.)</p>
<p><strong>Frame aborts (ABORTS).</strong> The level of error threshold
monitoring done by the system for frame aborts. (See the ABORTS parameter in
the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -4 means *OFF</li>
<li>Value of -5 means *MIN</li>
<li>Value of -6 means *MED</li>
<li>Value of -7 means *MAX</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Frame retry (FRAMERTY).</strong> The number of retries for an
unanswered or unacknowledged frame. (See the FRAMERTY parameter in the Control
Language (CL) information for the <a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>
or <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Frame retry limit (IDLCFRMRTY).</strong> The maximum number of frame
retransmissions to attempt before initiating recovery. (See the IDLCFRMRTY
parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -9 means *CNN</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Frame sequence errors (FRMSEQERR).</strong> The level of error
threshold monitoring done by the system for frame sequence errors. (See the
FRMSEQERR parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -4 means *OFF</li>
<li>Value of -5 means *MIN</li>
<li>Value of -6 means *MED</li>
<li>Value of -7 means *MAX</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Framing type (FRAMING).</strong> Specifies whether the line uses
asynchronous or synchronous framing. (See the FRAMING parameter in the Control
Language (CL) information for the <a href="../cl/crtlinppp.htm">CRTLINPPP</a>
command.)</p>
<p><strong>Function address.</strong> Functional address used by token-ring
network lines.</p>
<p><strong>Generate test frame (GENTSTFRM).</strong> Whether the system will
have test frames automatically generated. Test frames are used to detect
whether the Ethernet network has become inoperational during idle periods. (See
the GENTSTFRM parameter in the Control Language (CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> command.)</p>
<p><strong>Group address.</strong> The group of addresses to which a subset of
nodes on the network respond to, in addition to their local adapter
addresses.</p>
<p><strong>Idle timer (IDLTMR).</strong> The maximum allowable time between
characters before the adapter forwards the receive buffer to the system. (See
the IDLTMR parameter in the Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Inactivity timer (INACTTMR).</strong> The time that the system waits
for activity on a line before disconnecting. (See the INACTTMR parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>, or
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>Include STX character in the LRC (STXLRC).</strong> Whether to
exclude the start-of-text (STX) character in the longitudinal redundancy check
(LRC) calculation. (See the STXLRC parameter in the Control Language (CL)
information for the <a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Incoming connection list (CNNLSTIN).</strong> The name of the
connection list used to retrieve ISDN call information when authorizing
incoming calls. (See the CNNLSTIN parameter in the Control Language (CL)
information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Information transfer type (INFTRFTYPE).</strong> How data is to be
encoded for the ISDN B-channel associated with this line description. (See the
INFTRFTYPE parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Initialization program library name.</strong> The name of the
library in which the initialization program resides.</p>
<p><strong>Initialization program name.</strong> The name of a program that is
called to manage configuration initialization data.</p>
<p><strong>Initialization source file library name.</strong> The name of the
library in which the initialization source file resides.</p>
<p><strong>Initialization source file name.</strong> The name of a source file
containing configuration initialization data.</p>
<p><strong>Initialization source member name.</strong> The name of a source
member containing configuration initialization data.</p>
<p><strong>Insert network address in packets (ADRINSERT).</strong> Whether the
system inserts the local network address (NETADR) in call-request and
call-accept packets. (See the ADRINSERT parameter in the Control Language (CL)
information for the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>IOP attach flag.</strong> Specifies what type of Ethernet
IOP is attached.</p>
<ul>
<li>A value of 0 means an I/O processor (IOP) performs the majority of the processing of network traffic.</li>
<li>A value of 1 means System Licensed Internal Code performs the majority of the processing related to network traffic.</li>
<li>A value of 2 means System Licensed Internal Code and the IOP split the processing of network traffic.</li>
</ul>
<p><strong>LAN emulation client frame size (LECFRAME).</strong> The LAN
emulation client (LEC) frame size. (See the LECFRAME parameter in the Control
Language (CL) information for the <a href="../cl/crtlintrn.htm">CRTLINTRN</a>
command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -11 means *CALC</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong> Last contacted LES ATM address.</strong> Specifies the most
recently used LAN emulation server (LES) ATM network address associated with
this line.</p>
<ul>
<li><em>Element 1: Network prefix</em>: The network prefix of the ATM address
of the remote server. This is a 26 digit hexadecimal value.</li>
<li><em>Element 2: End-system-identifier</em>: The end system identifier of the
remote server. This is a 12 digit hexadecimal value.</li>
<li><em>Element 3: Selector byte</em>: The selector byte of the remote server.
This is a two digit hexadecimal value.</li>
</ul>
<p><strong>Note:</strong> These fields are no longer supported as of V5R3M0.</p>
<p><strong>LEC cache aging time.</strong> Specifies the time-out period for
which an address resolution protocol (ARP) entry will be cached without
verification of that entry.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>LEC disconnect time out (LECDSCTIMO).</strong> The amount of time in
minutes that a LAN emulation client will wait before disconnecting an idle
virtual circuit connection to another client. (See the LECDSCTIMO parameter in
the Control Language (CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>Line category.</strong> This value will be one of the following:</p>
<dl>
<dd>*ASC</dd>
<dd>*BSC</dd>
<dd>*DDI</dd>
<dd>*ETH</dd>
<dd>*FAX</dd>
<dd>*FR</dd>
<dd>*IDLC</dd>
<dd>*NET</dd>
<dd>*PPP</dd>
<dd>*SDLC</dd>
<dd>*TDLC</dd>
<dd>*TRN</dd>
<dd>*WLS</dd>
<dd>*X25</dd>
</dl>
<p>The category value is derived from the command used to create the line
description.</p>
<p><strong>Line name.</strong> The name of the line description.</p>
<p><strong>Line speed (LINESPEED).</strong> The line speed in bits per second
(bps). (See the LINESPEED parameter in the Control Language (CL) information
for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -11 means *CALC</li>
<li>Value of -23 means 10M</li>
<li>Value of -24 means 4M</li>
<li>Value of -25 means 16M</li>
<li>Value of -27 means *NWI</li>
<li>Value of -29 means 100M</li>
<li>Value of -30 means *AUTO</li>
<li>Value of -34 means 1G</li>
</ul>
<p><strong>Link control protocol authentication values (LCPAUT).</strong>
Specifies values controlling how the Link Control Protocol layer of i5/OS
Point-to-Point Protocol (PPP) authenticates a remote peer. (See the LCPAUT
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a> command.) These
values are returned in two separate fields:</p>
<ul>
<li><em>Remote peer challenge timer</em>: Specifies the interval, in minutes,
to periodically issue an authentication challenge to the remote peer.</li>
<li><em>Maximum authentication attempts</em>: Specifies the maximum number of
unacknowledged authentication challenges sent to a remote peer before assuming
that the peer is unable to respond.</li>
</ul>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of 0 means *NONE</li>
</ul>
<p><strong>Link control protocol configuration values (LCPCFG).</strong>
Specifies values controlling how the Link Control Protocol layer of i5/OS PPP
negotiates mutually acceptable link configuration values with a remote peer.
(See the LCPCFG parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a> command.) These values are
returned in four separate fields:</p>
<ul>
<li><em>Configuration retry timer</em>: Specifies the interval, in seconds,
that the system waits before resending an unacknowledged configuration,
termination, or authentication challenge request to a remote peer. This value
is returned in two seperate fields:
<ul>
<li>As an integer representing tenths of a second.</li>
<li>As a CHAR(10) string with the real number value in seconds.</li>
</ul>
</li>
<li><em>Maximum configuration failures</em>: Specifies the maximum number of
attempts that are made to negotiate a mutually acceptable configuration with a
remote peer before assuming that configuration is not converging.</li>
<li><em>Maximum configuration requests</em>: Specifies the maximum number of
unacknowledged configuration requests sent to a remote peer before assuming
that the peer is unable to respond.</li>
<li><em>Maximum termination requests</em>: Specifies the maximum number of
unacknowledged termination request packets sent to a remote peer before
assuming that the peer is unable to respond.</li>
</ul>
<p><strong>Link speed (LINKSPEED).</strong> The link speed in bits per second
(bps). (See the LINKSPEED parameter in the Control Language (CL) information
for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -5 means *MIN</li>
<li>Value of -7 means *MAX</li>
<li>Value of -12 means *INTERFACE</li>
<li>Value of -23 means 10 million bits per second</li>
<li>Value of -24 means 4 million bits per second</li>
<li>Value of -25 means 16 million bits per second</li>
<li>Value of -29 means 100 million bits per second</li>
</ul>
<p>Note: For Ethernet (LIND0500) and Token-Ring (LIND1000), link speeds over
one gigabit per second must be retrieved from two parameters as follows:
LINKSPEED = (link_speed_multiplier x (10**9)) + link_speed. For link speeds
less than one gigabit per second, the link speed multiplier will contain
zero.</p>
<p><strong>Link speed multiplier.</strong> For Ethernet (LIND0500) and
Token-Ring (LIND1000), link speeds over one gigabit per second must use this
multiplier to calculate the actual link speed as follows: LINKSPEED =
(link_speed_multiplier x (10**9)) + link_speed. For link speeds less than one
gigabit per second, the link speed multiplier will contain zero.</p>
<p><strong>Local ATM address.</strong> Specifies the local ATM network address
associated with this line.</p>
<ul>
<li><em>Element 1: Network prefix</em>: The network prefix of the ATM address
of the remote server. This is a 26 digit hexadecimal value.</li>
<li><em>Element 2: End-system-identifier</em>: The end system identifier of the
remote server. This is a 12 digit hexadecimal value.</li>
<li><em>Element 3: LAN emulation client (LEC) selector byte</em>: The LEC
selector byte. This is a two digit hexadecimal value.</li>
</ul>
<p><strong>Note:</strong> These fields are no longer supported as of V5R3M0.</p>
<p><strong>Local adapter address (ADPTADR).</strong> The address used by the
adapter for this line to transmit from and answer to on the token-ring or LAN.
(See the ADPTADR parameter in the Control Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinwls.htm">CRTLINWLS</a> command.)</p>
<p><strong>Local manager mode (LCLMGRMODE).</strong> The local manager mode
used with a distributed data interface (DDI) line. (See the LCLMGRMODE
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a> command.)</p>
<p><strong>Local network address (NETADR).</strong> The network address of the
system. (See the NETADR parameter in the Control Language (CL) information for
the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Log configuration changes (LOGCFGCHG).</strong> Whether the
token-ring network manager for this line is to log configuration changes on the
ring. (See the LOGCFGCHG parameter in the Control Language (CL) information for
the <a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Logging level (LOGLVL).</strong> The error logging level used with a
distributed data interface (DDI) line. (See the LOGLVL parameter in the Control
Language (CL) information for the <a href="../cl/crtlinddi.htm">CRTLINDDI</a>
command.)</p>
<p><strong>Logical channel controller.</strong> Either an SVC or an attached
PVC controller.</p>
<p>For a switched virtual circuit (SVC) logical channel, this is the controller
description currently active on this logical channel.</p>
<p>For a permanent virtual circuit (PVC) logical channel, this is the
controller description permanently attached to this logical channel.</p>
<p><strong>Logical channel identifier.</strong> An identifier consisting of 3
hexadecimal characters that can range from hex 001 to hex FFF. The first
character represents the logical channel group, as assigned by the network
subscription. The last 2 characters are the network-assigned logical channel
number.</p>
<p><strong>Logical channel type.</strong> The type of logical channel.</p>
<p><strong>Long retry (LONGRTY).</strong> The number of bursts of call retry
attempts that the system makes when processing a connection request. (See the
LONGRTY parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Long timer (LONGTMR).</strong> The length of time that the system
waits between connection retry attempts. (See the LONGTMR parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Maximum ARP entries.</strong> Specifies the maximum number of
address resolution protocol (ARP) table entries. This represents the maximum
number of LAN emulation MAC addresses that can be resolved at any point in
time.</p>
<p><strong>Maximum buffer size (MAXBUFFER).</strong> The maximum size of the
incoming and outgoing buffers. (See the MAXBUFFER parameter in the Control
Language (CL) information for the <a href="../cl/crtlinasc.htm">CRTLINASC</a> or
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Maximum controllers (MAXCTL).</strong> The maximum number of
controllers this line can support. (See the MAXCTL parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinwls.htm">CRTLINWLS</a> command.)</p>
<p><strong>Maximum frame size (MAXFRAME).</strong> The maximum frame size or
logical link control data unit that can be transmitted and received on this
line. (See the MAXFRAME parameter in the Control Language (CL) information for
the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Maximum outstanding frames (MAXOUT).</strong> The maximum number of
information frames that can be sent to a remote system and received from a
remote system before allowing the receiving system to respond. (See the MAXOUT
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Maximum packet size (MAXPKTSIZE).</strong> The maximum packet size
that can be used by any controller associated with this line description. This
information is returned in two separate fields:</p>
<ul>
<li><em>Transmit</em></li>
<li><em>Receive</em></li>
</ul>
<p>(See the MAXPKTSIZE parameter in the Control Language (CL) information for
the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -10 means *TRANSMIT</li>
<li>Value of -13 means *DFTPKTSIZE</li>
</ul>
<p><strong>Message queue (MSGQ).</strong> The message queue to which
operational messages for this line should normally be sent. Note that this is
the value entered on the MSGQ parameter of the CL command, but under certain
error conditions it may not be the message queue currently in use. See the
current message queue field to determine what message queue is actually being
used at a given time. (See the MSGQ parameter in the Control Language (CL)
information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)
This information is returned in two separate fields:</p>
<ul>
<li><em>Name</em> of the queue</li>
<li><em>Library</em> in which the queue can be found</li>
</ul>
<p><strong>Modem data rate select (MODEMRATE).</strong> Whether this modem is
being operated at its full rated speed, or at an alternate or half speed. (See
the MODEMRATE parameter in the Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Modem initialization command string (MDMINZCMD).</strong> The
command string to send to set the modem. (See the MDMINZCMD parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Modem type supported (MODEM).</strong> The type of modem diagnostic
tests to be used on the line. (See the MODEM parameter in the Control Language
(CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Modulus (MODULUS).</strong> Whether extended sequence numbers are
used (modulus 128) or not (modulus 8). (See the MODULUS parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Network controller (NETCTL).</strong> The name of an existing
network controller description. (See the NETCTL parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlintdlc.htm">CRTLINTDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Network interface DLC identifier.</strong> The data link control
(DLC) identifier used to connect to the network.</p>
<p><strong>Network server description (NWS).</strong> The name of the network
server to which the nonswitched line is attached. (See the NWS parameter in the
Control Language (CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Network user identification facility (NETUSRID).</strong> Allows
X.25 network subscribers to specify the network user identification (NUI)
selection facility that is encoded in the facility field of all call request
packets sent on this line. (See the NETUSRID parameter in the Control Language
(CL) information for the <a href="../cl/crtlinx25.htm">CRTLINX25</a>
command.)</p>
<p><strong>Nonproductive receive timer (NPRDRCVTMR).</strong> The time that the
system waits for either a final frame or an idle signal while the secondary
station is continuously transmitting. (See the NPRDRCVTMR parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>NRZI data encoding (NRZI).</strong> Whether the system uses the
non-return-to-zero inverted (NRZI) transmission coding method. (See the NRZI
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a> or
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Number of active switched controllers.</strong> The number of
elements in the list of active switched controllers returned with this format.
A value of zero is returned if the list is empty.</p>
<p><strong>Number of attached nonswitched controllers.</strong> The number of
elements in the list of attached nonswitched controllers returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Number of call progress signal retry values.</strong> The number of
elements in the list of call progress signal retry values returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Number of EOR characters.</strong> The number of elements in the
list of end-of-record (EOR) characters returned with this format. A value of
zero is returned if the list is empty.</p>
<p><strong>Number of function addresses.</strong> The number of elements in the
list of function addresses returned with this format. A value of zero is
returned if the list is empty.</p>
<p><strong>Number of group addresses.</strong> The number of elements in the
list of group addresses returned with this format. A value of zero is returned
if the list is empty.</p>
<p><strong>Number of logical channel entries.</strong> The number of elements
in the list of logical channel entries returned with this format. A value of
zero is returned if the list is empty.</p>
<p><strong>Number of PVC identifiers.</strong> The number of elements in the
list of permanent virtual circuits returned with this format. A value of zero
is returned if the list is empty.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Number of resource names.</strong> The number of elements in the
list of resource names returned with this format. A value of zero is returned
if the list is empty.</p>
<p><strong>Number of SSAPs.</strong> The number of elements in the list of
source service access points (SSAPs) returned with this format. A value of zero
is returned if the list is empty.</p>
<p><strong>Number of switched controllers.</strong> The number of elements in
the list of switched controllers returned with this format. A value of zero is
returned if the list is empty.</p>
<p><strong>Number of switched NWIs.</strong> The number of elements in the list
of switched network interface (NWI) descriptions returned with this format. A
value of zero is returned if the list is empty.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Number of trailing characters.</strong> The value returned with each
element in the list of EOR characters.</p>
<p><strong>NWI channel number (NWICHLNBR).</strong> The network interface (NWI)
channel to be used by this line description. (See the NWICHLNBR parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>NWI channel type (NWICHLTYPE).</strong> The type of network
interface channels to be used by this line description. (See the NWICHLTYPE
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>NWI name.</strong> The name of the existing network interface
description.</p>
<p><strong>Offset to list of active switched controllers.</strong> The offset
in bytes to the first element in the list of active switched controllers
returned with this format. A value of zero is returned if the list is
empty.</p>
<p><strong>Offset to list of attached nonswitched controllers.</strong> The
offset in bytes to the first element in the list of attached nonswitched
controllers returned with this format. A value of zero is returned if the list
is empty.</p>
<p><strong>Offset to list of call progress signal retry values.</strong> The
offset in bytes to the first element in the list of call progress signal retry
values returned with this format. A value of zero is returned if the list is
empty.</p>
<p><strong>Offset to list of EOR characters.</strong> The offset in bytes to
the first element in the list of EOR characters returned with this format. A
value of zero is returned if the list is empty.</p>
<p><strong>Offset to list of function addresses.</strong> The offset in bytes
to the first element in the list of function addresses returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Offset to list of group addresses.</strong> The offset in bytes to
the first element in the list of group addresses returned with this format. A
value of zero is returned if the list is empty.</p>
<p><strong>Offset to list of logical channel entries.</strong> The offset in
bytes to the first element in the list of logical channel entries returned with
this format. A value of zero is returned if the list is empty.</p>
<p><strong>Offset to list of PVC identifiers.</strong> The offset in bytes to
the first element in the list of permanent virtual circuits returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Offset to list of resource names.</strong> The offset in bytes to
the first element in the list of resource names returned with this format. A
value of zero is returned if the list is empty.</p>
<p><strong>Offset to list of SSAPs.</strong> The offset in bytes to the first
element in the list of source service access points (SSAPs) returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Offset to list of switched controllers.</strong> The offset in bytes
to the first element in the list of switched controllers returned with this
format. A value of zero is returned if the list is empty.</p>
<p><strong>Offset to list of switched NWIs.</strong> The offset in bytes to the
first element in the list of switched network interface (NWI) descriptions
returned with this format. A value of zero is returned if the list is
empty.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Online at IPL (ONLINE).</strong> Whether or not the line is varied
on automatically when the system is turned on. (See the ONLINE parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfax.htm">CRTLINFAX</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintdlc.htm">CRTLINTDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Outgoing connection list (CNNLSTOUT).</strong> For switched ISDN
connections, the name of a connection list containing the network-assigned
numbers used for outgoing calls on this controller. (See the CNNLSTOUT
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a> or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Outgoing connection list entry (CNNLSTOUTE).</strong> For switched
ISDN connections, the name of the connection list entry containing the
network-assigned numbers used for outgoing calls on this line. (See the
CNNLSTOUTE parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a> or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Packet mode (PKTMODE).</strong> Allows the system to communicate
directly with another system by using the B-channel X.25 virtual circuit
service integrated within an ISDN. (See the PKTMODE parameter in the Control
Language (CL) information for the <a href="../cl/crtlinx25.htm">CRTLINX25</a>
command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>PVC identifiers (PVCID).</strong> Specifies the virtual path
identifier and virtual circuit ID. (See the PVCID parameter in the Control
Language (CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Physical interface (INTERFACE).</strong> The type of physical
communications line interface that this communications adapter port and cable
will be attached to. (See the INTERFACE parameter in the Control Language (CL)
information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Poll cycle pause (POLLPAUSE).</strong> The length of time that the
system waits after the last remote system in the poll list is polled before
beginning another pass through the poll list. (See the POLLPAUSE parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Poll response delay (POLLRSPDLY).</strong> The minimum duration of
time that the system waits before it responds to a data poll if there is no
information frame to transmit. (See the POLLRSPDLY parameter in the Control
Language (CL) information for the <a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>
command.)</p>
<p><strong>Port number.</strong> The port number on the network server to which
this line is physically attached.</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -28 means *INTERNAL</li>
<li>Value of -36 means *VRTETHPTP</li>
<li>Value of -40 means *VRTETH0</li>
<li>Value of -41 means *VRTETH1</li>
<li>Value of -42 means *VRTETH2</li>
<li>Value of -43 means *VRTETH3</li>
<li>Value of -44 means *VRTETH4</li>
<li>Value of -45 means *VRTETH5</li>
<li>Value of -46 means *VRTETH6</li>
<li>Value of -47 means *VRTETH7</li>
<li>Value of -48 means *VRTETH8</li>
<li>Value of -49 means *VRTETH9</li>
</ul>
<p><strong>Predial delay (PREDIALDLY).</strong> The length of time to wait
before dialing the number to establish a connection to the remote system or
network. (See the PREDIALDLY parameter in the Control Language (CL) information
for the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Propagation delay (PRPDLY).</strong> The time required for a signal
to travel from one end of a link to the other end. (See the PRPDLY parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Receive overrun (OVERRUN).</strong> The level of error threshold
monitoring done by the system for receive overrun errors. (See the OVERRUN
parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -4 means *OFF</li>
<li>Value of -5 means *MIN</li>
<li>Value of -6 means *MED</li>
<li>Value of -7 means *MAX</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Receive timer (RCVTMR).</strong> The maximum amount of time the
system waits for a response from the remote system before a time-out occurs.
(See the RCVTMR parameter in the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Receive TTD or WACK retry (RCVRTY).</strong> The number of times
that a temporary text delay (TTD) or wait-before-transmit-positive
acknowledgement (WACK) is received before the session fails. (See the RCVRTY
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>Recovery limits (CMNRCYLMT).</strong> The second-level
communications recovery limit for each line description. These limits are
returned in two separate fields:</p>
<ul>
<li><em>Count limit</em>: The number of second-level recovery attempts to be
automatically performed by the system.</li>
<li><em>Time interval</em>: The length of time (in minutes) in which the
specified number of second-level recoveries can be attempted.</li>
</ul>
<p>(See the CMNRCYLMT parameter in the Control Language (CL) information for
the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -14 means *SYSVAL</li>
</ul>
<p><strong>Redial delay (REDIALDLY).</strong> The length of time to wait before
redialing the number to establish a connection to the remote system or network
if the previous attempt was unsuccessful. (See the REDIALDLY parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>LES ATM address (LESATMADR).</strong> Specifies the ATM network
address of the remote LAN emulation server. (See the LESATMADR parameter in the
Control Language (CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)
This address is returned in three separate fields:</p>
<ul>
<li><em>Element 1: Network prefix</em>: The network prefix of the ATM address
of the remote server. This is a 26 digit hexadecimal value.</li>
<li><em>Element 2: End system identifier</em>: Specify the end system
identifier of the remote server. This is a 12 digit hexadecimal value.</li>
<li><em>Element 3: Selector byte</em>: The selector byte of the remote server.
This is a two digit hexadecimal value.</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Remote answer timer (RMTANSTMR).</strong> The length of time that
the system should wait for the modem (DCE) to raise Data Set Ready (DSR) after
dialing before signaling an error. (See the RMTANSTMR parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Reported emulated LAN name.</strong> The reported emulated LAN
name.</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Reserved.</strong> Space included for alignment.</p>
<p><strong>Response timer (IDLCRSPTMR).</strong> The length of time to wait
before retransmitting a frame when an acknowledgement is not received. (See the
IDLCRSPTMR parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -9 means *CNN</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Resource name (RSRCNAME).</strong> The unique name that is assigned
by the system to the physical equipment (in this case, a communications port)
attached to the system. (See the RSRCNAME parameter in the Control Language
(CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfax.htm">CRTLINFAX</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Retransmitted frames (RETRANSMIT).</strong> The level of error
threshold monitoring done by the system for retransmitted frames. (See the
RETRANSMIT parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -4 means *OFF</li>
<li>Value of -5 means *MIN</li>
<li>Value of -6 means *MED</li>
<li>Value of -7 means *MAX</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Security for line (SECURITY).</strong> The types of security
protection available on the line. (See the SECURITY parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Segment number.</strong> The unique number that identifies the LAN
to which the network server is attached.</p>
<p><strong>Set modem to ASYNC command (SETMDMASC).</strong> The V25BIS command
that is used to set the modem to ASYNC mode. (See the SETMDMASC parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a> or
<a href="../cl/crtlinppp.htm">CRTLINPPP</a> command.)</p>
<p><strong>Short frame (SHORTFRAME).</strong> The level of error threshold
monitoring done by the system for short frame errors. (See the SHORTFRAME
parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -4 means *OFF</li>
<li>Value of -5 means *MIN</li>
<li>Value of -6 means *MED</li>
<li>Value of -7 means *MAX</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>SHM access code (SHMACC).</strong> The access code used by an X.21
short-hold mode (SHM) line when calling a system on another network. (See the
SHMACC parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>SHM answer delay timer (SHMANSDLY).</strong> The length of time the
system waits for controllers to call in before attempting to call out. (See the
SHMANSDLY parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>SHM call format (SHMCALLFMT).</strong> The format of the network
identifier used in the local system's connection number. (See the SHMCALLFMT
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>SHM call timer (SHMCALLTMR).</strong> The interval at which a
connection is reestablished on an X.21 short-hold mode line to verify the state
of the remote system if no normal data traffic occurs in the specified
interval. (See the SHMCALLTMR parameter in the Control Language (CL)
information for the <a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -3 means *NONE</li>
</ul>
<p><strong>SHM maximum connect timer (SHMMAXCNN).</strong> The length of time
the system allows connection to any one controller when there are more
controllers than there are available ports. (See the SHMMAXCNN parameter in the
Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>SHM node type (SHMNODE).</strong> The physical unit type of the
controllers using the X.21 short-hold mode line. (See the SHMNODE parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Short retry (SHORTRTY).</strong> The number of retry attempts that
the system makes during a burst of call retries. (See the SHORTRTY parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Short timer (SHORTTMR).</strong> The length of time that the system
waits between retry attempts when processing a connection request. (See the
SHORTTMR parameter in the Control Language (CL) information for the
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>SSAP address.</strong> The hexadecimal logical channel address that
is used to route data off the line to the proper user.</p>
<p><strong>SSAP maximum frame.</strong> The largest frame size allowed on this
source service access point (SSAP).</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -26 means *MAXFRAME</li>
</ul>
<p><strong>SSAP type.</strong> The type of communications used by the system on
this SSAP.</p>
<p><strong>Station address (STNADR).</strong> The address used by the remote
control station to poll the system. (See the STNADR parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> or
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Stop bits (STOPBITS).</strong> The number of bits to be added to the
end of each character to keep the local and remote ends of the line
synchronized. (See the STOPBITS parameter in the Control Language (CL)
information for the <a href="../cl/crtlinasc.htm">CRTLINASC</a> command.)</p>
<p><strong>Switched connection type (SWTCNN).</strong> Whether the line can be
used for incoming and outgoing calls, incoming calls only, or outgoing calls
only. (See the SWTCNN parameter in the Control Language (CL) information for
the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Switched controller name.</strong> The name of a controller
associated with this line.</p>
<p><strong>Switched disconnect (SWTDSC).</strong> For switched lines
(CNN(*SWTPP)), whether the line is to be dropped when no virtual circuits are
active and the disconnection timers specified on the SWTDSCTMR parameter have
expired. (See the SWTDSC parameter in the Control Language (CL) information for
the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Switched disconnect timers (SWTDSCTMR).</strong> The timers used for
disconnecting switched lines from a network or remote system. The timer values
are returned in two separate fields:</p>
<ul>
<li><em>Minimum connection</em>: The minimum length of time the system keeps
the connection active.</li>
<li><em>Disconnect delay</em>: The length of time the system waits before
attempting to disconnect the switched connection when the line is idle and the
minimum connection time has expired.</li>
</ul>
<p>(See the SWTDSCTMR parameter in the Control Language (CL) information for
the <a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Switched network backup (SNBU).</strong> Whether or not you want the
switched network backup capability. (See the SNBU parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> or
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a> command.)</p>
<p><strong>Switched NWI selection (SWTNWISLCT).</strong> The method used to
select network interface (NWI) descriptions from the switched NWI list. (See
the SWTNWISLCT parameter in the Control Language (CL) information for the
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>SYN characters (SYNCCHARS).</strong> The number of SYN characters
used to establish and maintain synchronization and as time-fill characters in
the absence of any data or other control character. (See the SYNCCHARS
parameter in the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><strong>Text description (TEXT).</strong> A brief description of the line
and its location. (See the TEXT parameter in the Control Language (CL)
information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfax.htm">CRTLINFAX</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintdlc.htm">CRTLINTDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Time information retrieved.</strong> The time that the information
was provided by the API. It is returned as 6 characters in the form HHMMSS,
where:</p>
<table cellpadding="5">
<!-- cols="15 85" -->
<tr>
<td align="left" valign="top"><em>HH</em></td>
<td align="left" valign="top">Hour</td>
</tr>
<tr>
<td align="left" valign="top"><em>MM</em></td>
<td align="left" valign="top">Minute</td>
</tr>
<tr>
<td align="left" valign="top"><em>SS</em></td>
<td align="left" valign="top">Second</td>
</tr>
</table>
<p><strong>Token-ring inform of beacon (TRNINFBCN).</strong> Whether the
token-ring network manager for this line is to provide notification of
beaconing on the ring to the system operator. (See the TRNINFBCN parameter in
the Control Language (CL) information for the
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Token rotation time.</strong> The token rotation time requested when
the line was created. (See the TKNRTTTIME parameter in the Control Language
(CL) information for the <a href="../cl/crtlinddi.htm">CRTLINDDI</a>
command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -11 means *CALC</li>
</ul>
<p><strong>Transmit TTD or WACK retry (TMTRTY).</strong> The number of times
that a temporary-text-delay (TTD) or wait-before-transmit-positive
acknowledgement (WACK) control character is sent to hold up the line when the
system is not ready to respond to the remote end. (See the TMTRTY parameter in
the Control Language (CL) information for the
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -8 means *NOMAX</li>
</ul>
<p><strong>Transmit underrun (UNDERRUN).</strong> The level of error threshold
monitoring done by the system for transmit underrun errors. (See the UNDERRUN
parameter in the Control Language (CL) information for the
CRTLINIDLC command.)</p>
<p><em>Exceptions:</em></p>
<ul>
<li>Value of -4 means *OFF</li>
<li>Value of -5 means *MIN</li>
<li>Value of -6 means *MED</li>
<li>Value of -7 means *MAX</li>
</ul>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>TRLAN manager logging level (TRNLOGLVL).</strong> The logging level
to be used by the token-ring network manager. This information is returned in
two separate fields:</p>
<ul>
<li><em>Configured</em></li>
<li><em>Current</em></li>
</ul>
<p>(See the TRNLOGLVL parameter in the Control Language (CL) information for
the <a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>TRLAN manager mode (TRNMGRMODE).</strong> Whether the token-ring
network manager for this line is operating in observing or controlling mode.
(See the TRNMGRMODE parameter in the Control Language (CL) information for the
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Use LECS address (USELECSADR).</strong> Specifies whether the local
system contacts the LAN emulation server (LES) address. (See the USELECSADR
parameter in the Control Language (CL) information for the
<a href="../cl/crtlineth.htm">CRTLINETH</a> or
<a href="../cl/crtlintrn.htm">CRTLINTRN</a> command.)</p>
<p><strong>Note:</strong> This field is no longer supported as of V5R3M0.</p>
<p><strong>Type of parity (PARITY).</strong> The type of parity for error
checking. (See the PARITY parameter in the Control Language (CL) information
for the <a href="../cl/crtlinasc.htm">CRTLINASC</a> command.)</p>
<p><strong>User-defined 1, 2, and 3 (USRDFN1, USRDFN2, USRDFN3).</strong> Used
to describe any unique characteristics of the line that you want to control.
(See the USRDFN1, USRDFN2, or USRDFN3 parameter in the Control Language (CL)
information for the
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>Vary on wait (VRYWAIT).</strong> Whether the line is varied on
synchronously or asynchronously. (See the VRYWAIT parameter in the Control
Language (CL) information for the
<a href="../cl/crtlinasc.htm">CRTLINASC</a>,
<a href="../cl/crtlinbsc.htm">CRTLINBSC</a>,
<a href="../cl/crtlinddi.htm">CRTLINDDI</a>,
<a href="../cl/crtlineth.htm">CRTLINETH</a>,
<a href="../cl/crtlinfax.htm">CRTLINFAX</a>,
<a href="../cl/crtlinfr.htm">CRTLINFR</a>,
<a href="../cl/crtlinppp.htm">CRTLINPPP</a>,
<a href="../cl/crtlinsdlc.htm">CRTLINSDLC</a>,
<a href="../cl/crtlintrn.htm">CRTLINTRN</a>,
<a href="../cl/crtlinwls.htm">CRTLINWLS</a>, or
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><em>Exception:</em></p>
<ul>
<li>Value of -15 means *NOWAIT</li>
</ul>
<p><strong>Virtual hardware.</strong> Specifies whether a real Ethernet line or
a virtual Ethernet LAN adapter is associated with the line description.</p>
<ul>
<li>A value of *NO means a real Ethernet line is used.</li>
<li>A value of *YES means a virtual Ethernet LAN adapter is used.</li>
</ul>
<p><strong>X.25 DCE support (X25DCE).</strong> Allows the system to communicate
directly with another system without going through an X.25 network. (See the
X25DCE parameter in the Control Language (CL) information for the
<a href="../cl/crtlinx25.htm">CRTLINX25</a> command.)</p>
<p><strong>XOFF character (XOFFCHAR).</strong> The hexadecimal value used to
tell your line to stop sending data. (See the XOFFCHAR parameter in the Control
Language (CL) information for the <a href="../cl/crtlinasc.htm">CRTLINASC</a>
command.)</p>
<p><strong>XON character (XONCHAR).</strong> The hexadecimal value used to tell
your line to start sending data. (See the XONCHAR parameter in the Control
Language (CL) information for the <a href="../cl/crtlinasc.htm">CRTLINASC</a>
command.)</p>
<br>
<h3>Error Messages</h3>
<table width="100%" cellpadding="5">
<!-- cols="15 85" -->
<tr>
<th align="left" valign="top">Message ID</th>
<th align="left" valign="top">Error Message Text</th>
</tr>
<tr>
<td align="left" valign="top">CPF24B4 E</td>
<td align="left" valign="top">Severe error while addressing parameter
list.</td>
</tr>
<tr>
<td align="left" valign="top">CPF2625 E</td>
<td align="left" valign="top">Not able to allocate object &amp;1.</td>
</tr>
<tr>
<td align="left" valign="top">CPF2634 E</td>
<td align="left" valign="top">Not authorized to object &amp;1.</td>
</tr>
<tr>
<td align="left" valign="top">CPF26A7 E</td>
<td align="left" valign="top">Category of object not compatible with API
format.</td>
</tr>
<tr>
<td align="left" valign="top">CPF26B2 E</td>
<td align="left" valign="top">NetBIOS description &amp;1 previously
deleted.</td>
</tr>
<tr>
<td align="left" valign="top">CPF2703 E</td>
<td align="left" valign="top">Controller description &amp;1 not found.</td>
</tr>
<tr>
<td align="left" valign="top">CPF2704 E</td>
<td align="left" valign="top">Line description &amp;1 not found.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C19 E</td>
<td align="left" valign="top">Error occurred with receiver variable
specified.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C21 E</td>
<td align="left" valign="top">Format name &amp;1 is not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C24 E</td>
<td align="left" valign="top">Length of the receiver variable is not
valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3CF1 E</td>
<td align="left" valign="top">Error code parameter not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3C90 E</td>
<td align="left" valign="top">Literal value cannot be changed.</td>
</tr>
<tr>
<td align="left" valign="top">CPF8104 E</td>
<td align="left" valign="top">Controller description &amp;4 damaged.</td>
</tr>
<tr>
<td align="left" valign="top">CPF811D E</td>
<td align="left" valign="top">Network interface description &amp;4
damaged.</td>
</tr>
<tr>
<td align="left" valign="top">CPF8125 E</td>
<td align="left" valign="top">Line description &amp;4 damaged.</td>
</tr>
<tr>
<td align="left" valign="top">CPF9872 E</td>
<td align="left" valign="top">Program or service program &amp;1 in library
&amp;2 ended. Reason code &amp;3.</td>
</tr>
</table>
<br>
<hr>
API introduced: V2R3
<hr>
<table align="center" cellpadding="2" cellspacing="2">
<tr align="center">
<td valign="middle" align="center"><a href="#Top_Of_Page">Top</a> | <a href=
"config.htm">Configuration APIs</a> | <a href="aplist.htm">APIs by
category</a></td>
</tr>
</table>
</body>
</html>