<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="Select a LAN IOA and create the Ethernet line description" />
<meta name="DC.Relation" scheme="URI" content="rzajyconfiguresnaoverethernet.htm" />
<meta name="DC.Relation" scheme="URI" content="rzajycreatingcontrollerdescription.htm" />
<meta name="DC.Relation" scheme="URI" content="rzajylanioaaddresses.htm" />
<meta name="DC.Relation" scheme="URI" content="rzajysnaserviceaccesspoints.htm" />
<meta name="DC.Relation" scheme="URI" content="rzajytypesofethernetframessent.htm" />
<meta name="DC.Relation" scheme="URI" content="rzajyethernetioas.htm" />
<meta name="DC.Relation" scheme="URI" content="rzajysnacontolanprotocols.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1999, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1999, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzajycreatingethernetld" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Select a LAN IOA and create the Ethernet line description</title>
</head>
<body id="rzajycreatingethernetld"><a name="rzajycreatingethernetld"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Select a LAN IOA and create the Ethernet line description</h1>
<div><div class="section"> <div class="note"><span class="notetitle">Note:</span> The steps below describe only the fields that require additional
information. If you need help with the fields that are not discussed here,
press F1 (Help) when your cursor is on the field in question.</div>
</div>
<ol><li class="stepexpand"><span>Type <kbd class="userinput">WRKHDWRSC *CMN</kbd> and press Enter. A list
will appear that shows the attached <span class="keyword">iSeries™</span> communications
resources, and their type numbers, operational statuses, and descriptive text.</span></li>
<li class="stepexpand"><span>Locate an IOA by looking in the descriptive text column for a phrase
that describes the port for your LAN type. For example, if you use Ethernet,
look for "Ethernet Port."</span></li>
<li class="stepexpand"><span>Once you find an IOA, move your cursor to its <strong>Opt</strong> field.</span></li>
<li class="stepexpand"><span>Type <kbd class="userinput">5</kbd> (Work with configuration descriptions)
and press <kbd class="userinput">Enter</kbd>.</span></li>
<li class="stepexpand"><span>Type <kbd class="userinput">1</kbd> (Create) and press <kbd class="userinput">Enter</kbd>.</span> <div class="p">You are now in the Create Line Description (Ethernet) (CRTLINETH)
screen. <div class="note"><span class="notetitle">Note:</span> The server enters the IOA you selected into the <strong>Resource</strong> name
field.</div>
</div>
To move from field to field, move your cursor or press the
tab key. Do not press Enter while you are in this screen unless instructed
to do so; otherwise you will exit the command.</li>
<li class="stepexpand"><span>Type a name for your line description into the <strong>Line description</strong> field.</span></li>
<li class="stepexpand"><span>Indicate the address to use with the IOA in the <strong>Local adapter</strong> address
field.</span> You can use either the preset address or a locally administered
address. If you are unsure which address to use, see the LAN IOA addresses
topic.<p>To use the preset address, accept the default value of <span class="parmname">*ADPT</span>.
To specify a locally administered address, enter a valid address into the
field. For guidelines on creating a valid address, move your cursor to the
address field and press F1 (Help).</p>
</li>
<li class="stepexpand"><span>If the server uses this line description to communicate with an
SNA host through a parallel connection, specify a value other than *LIND in
the <strong>SNA Exchange identifier</strong> field.</span></li>
<li class="stepexpand"><span>In the <strong>Ethernet standard</strong> field, specify the standard to
use.</span> If you can use SNA over IEEE 802.3 or Ethernet version 2,
use the <kbd class="userinput">*ALL</kbd> value on the <span class="parmname">ETHSTD</span> parameter. <p>For
information about how the selected standard influences the type of Ethernet
frame your server sends, see the Types of Ethernet frames sent topic.</p>
<div class="note"><span class="notetitle">Note:</span> You
cannot change this field after exiting the command.</div>
</li>
<li class="stepexpand"><span>In the <strong>Line speed</strong> field, indicate the line speed to use.</span> If you do not know the capabilities of the IOA, see the Hardware requirements
for Ethernet topic. <div class="note"><span class="notetitle">Note:</span> Line speed automatic negotiation occurs when you
specify <kbd class="userinput">*AUTO</kbd>. </div>
</li>
<li class="stepexpand"><span>Select the duplex mode to use with your IOA.</span> If you
do not know the capabilities of the IOA, see the Hardware requirements for
Ethernet topic.<div class="note"><span class="notetitle">Note:</span> Duplex mode automatic negotiation occurs when you specify
*AUTO. Remember that your Ethernet switch or hub must support automatic negotiation
before you can successfully use this function. If the device does not support
it, a duplex mismatch can occur, causing connection problems. For more information
see the Auto-sensing topic.</div>
</li>
<li class="stepexpand"><span>Press <kbd class="userinput">F10</kbd> (Additional fields).</span></li>
<li class="stepexpand"><span>List all the source service access points (SSAP) that your controller
description can use in the <strong>SSAP</strong> field. Accept the default value *SYSGEN
or specify your SSAPs. To define the SSAP values, move your cursor to the
field and press <kbd class="userinput">F1</kbd> (Help) for help to determine what
values to use.</span> For more information on whether you or the server
should define the service access points (SAPs), see the SNA connections to
LAN protocols topic.</li>
<li class="stepexpand"><span>Leave the <strong>SSAP maximum frame</strong> field blank.</span></li>
<li class="stepexpand"><strong>Optional: </strong><span>In the <strong>Autocreate</strong> controller field,
specify <kbd class="userinput">*YES</kbd> if you use APPN and want the server to
create a controller description. (The server will create the description when
a call comes in.) If you specified <kbd class="userinput">*YES</kbd>,
you do not need to create a device description.</span></li>
<li class="stepexpand"><span>Press <kbd class="userinput">Enter</kbd> to create the line description.
Your line description will appear at the bottom of the list.</span></li>
<li class="stepexpand"><span>Press <kbd class="userinput">Enter</kbd> twice.</span></li>
</ol>
<div class="section"></div>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzajyconfiguresnaoverethernet.htm">Configure SNA over Ethernet</a></div>
<div class="nextlink"><strong>Next topic:</strong> <a href="rzajycreatingcontrollerdescription.htm">Create the SNA controller description</a></div>
</div>
<div class="relconcepts"><strong>Related concepts</strong><br />
<div><a href="rzajylanioaaddresses.htm" title="Learn about IOA preset addresses.">LAN IOA addresses</a></div>
<div><a href="rzajysnacontolanprotocols.htm" title="You can connect your server to a LAN using SNA, and can have multiple service access points.">SNA connections to LAN protocols</a></div>
</div>
<div class="relref"><strong>Related reference</strong><br />
<div><a href="rzajysnaserviceaccesspoints.htm">SNA service access points (SAPs)</a></div>
<div><a href="rzajytypesofethernetframessent.htm" title="Understand the different types of Ethernet frames that can be sent.">Types of Ethernet frames sent</a></div>
<div><a href="rzajyethernetioas.htm" title="Find out what IOAs are supported and what capabilities each one has.">Hardware requirements for Ethernet</a></div>
</div>