<meta name="DC.Title" content="Meet Operations Console hardware requirements" />
|
||
|
<meta name="abstract" content="You need to meet the following PC and iSeries hardware requirements for an Operations Console configuration." />
|
||
|
<meta name="description" content="You need to meet the following PC and iSeries hardware requirements for an Operations Console configuration." />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrverifyrequirements.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrscenariothree.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrminnetwork.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrcables.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrsoftwarereq.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigratingda.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigrateiseries.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigrateiseries2.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigratingtwinax.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigratingserver3.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigserver3.htm" />
|
||
|
<meta name="DC.Relation" scheme="URI" content="rzajrmigratingopscon.htm" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
|
||
|
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
|
||
|
<meta name="DC.Format" content="XHTML" />
|
||
|
<meta name="DC.Identifier" content="hardwarereq" />
|
||
|
<meta name="DC.Language" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="./ic.css" />
|
||
|
<title>Meet Operations Console hardware requirements</title>
|
||
|
</head>
|
||
|
<body id="hardwarereq"><a name="hardwarereq"><!-- --></a>
|
||
|
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
|
||
|
<h1 class="topictitle1">Meet Operations Console hardware requirements</h1>
|
||
|
<div><p>You need to meet the following PC and iSeries™ hardware requirements for an
|
||
|
Operations Console configuration.</p>
|
||
|
<div class="section"><p>Table 1 shows the PC requirements per operating system.</p>
|
||
|
</div>
|
||
|
<div class="section"><div class="p">
|
||
|
<div class="tablenoborder"><img src="./delta.gif" alt="Start of change" /><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><caption>Table 1. PC requirements - processor and memory</caption><thead align="left"><tr><th valign="top" id="d0e62">Operating System<sup>®</sup> (1,2)</th>
|
||
|
<th valign="top" id="d0e66">Operations Console PC</th>
|
||
|
</tr>
|
||
|
</thead>
|
||
|
<tbody><tr><td valign="top" headers="d0e62 ">Windows 2000<sup>®</sup> </td>
|
||
|
<td valign="top" headers="d0e66 "><ul><li>Pentium<sup>®</sup> 500
|
||
|
MHz recommended</li>
|
||
|
<li>128 MB memory minimum (256 MB recommended)</li>
|
||
|
</ul>
|
||
|
</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e62 ">Windows<sup>®</sup> XP Professional</td>
|
||
|
<td valign="top" headers="d0e66 "><ul><li>Pentium 500
|
||
|
MHz (P6 or equivalent compatible microprocessor)</li>
|
||
|
<li>256 MB memory minimum </li>
|
||
|
</ul>
|
||
|
</td>
|
||
|
</tr>
|
||
|
</tbody>
|
||
|
</table>
|
||
|
<img src="./deltaend.gif" alt="End of change" /></div>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div class="section"><div class="note"><span class="notetitle">Note:</span> <ol><li>See the iSeries Access
|
||
|
web site for any updated <a href="http://www.ibm.com/eservers/iseries/access/v5r2pcreq.htm" target="_blank">PC requirements</a>.</li>
|
||
|
<li>If you are using iSeries Navigator, refer to the <a href="../rzaj2/rzaj2pchrdware.htm">requirements for installing iSeries Navigator</a>.</li>
|
||
|
<li>If your PC has power management capabilities, it could turn the PC off.
|
||
|
The PC may reset the communications port when power management is started,
|
||
|
which would end any connections already established. Certain types of power
|
||
|
management on the PC and in the operating system may cause system reference
|
||
|
code (SRC) <samp class="codeph">0000DDDD</samp> to appear in the iSeries control panel or remote control
|
||
|
panel. This SRC data should clear when PC activity resumes.</li>
|
||
|
</ol>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div class="section"><div class="p">If you want to use an Operations Console local console on a network
|
||
|
(LAN), you need to install the LAN adapter for Operations Console according
|
||
|
to your iSeries model. IBM<sup>®</sup> supports
|
||
|
a local console on a network (LAN) only on Models 270 and 8xx. Table 2 shows
|
||
|
the supported cards for LAN connectivity. Table 3 shows the correct location
|
||
|
for the LAN card. <div class="note"><span class="notetitle">Note:</span> Supported cards and locations are only for non-partitioned
|
||
|
servers or primary partitions. For logical partitions in an LPAR environment,
|
||
|
any Operations Console supported adapter can be used.</div>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div class="section"><div class="important"><span class="importanttitle">Important:</span> If an emergency arises where your LAN connection
|
||
|
fails, you should configure an Operations Console local console directly attached
|
||
|
to the server. See <a href="rzajrbackupconsole.htm#backupconsole">Planning
|
||
|
for your backup console</a>. Table 3 also shows the correct location for
|
||
|
the directly cabled console.</div>
|
||
|
</div>
|
||
|
<div class="section"><div class="p">
|
||
|
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><caption>Table 2. Supported cards for LAN connectivity</caption><thead align="left"><tr><th valign="top" width="38.69346733668342%" id="d0e154">Card name or number</th>
|
||
|
<th valign="top" width="61.30653266331658%" id="d0e156">Description</th>
|
||
|
</tr>
|
||
|
</thead>
|
||
|
<tbody><tr><td valign="top" width="38.69346733668342%" headers="d0e154 ">2744</td>
|
||
|
<td valign="top" width="61.30653266331658%" headers="d0e156 ">PCI 100 Mbps Token ring Adapter</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" width="38.69346733668342%" headers="d0e154 ">2838</td>
|
||
|
<td valign="top" width="61.30653266331658%" headers="d0e156 ">PCI 100/10 Mbps Ethernet IOA</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" width="38.69346733668342%" headers="d0e154 ">2849</td>
|
||
|
<td valign="top" width="61.30653266331658%" headers="d0e156 ">PCI 100/10 Mbps Ethernet IOA</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" width="38.69346733668342%" headers="d0e154 ">Integrated Ethernet Port</td>
|
||
|
<td valign="top" width="61.30653266331658%" headers="d0e156 ">PCI 100/10 Mbps Integrated LAN IOA (model 825 only)</td>
|
||
|
</tr>
|
||
|
<tr><td colspan="2" valign="top" headers="d0e154 d0e156 "><div class="note"><span class="notetitle">Note:</span> The Integrated Ethernet Port is
|
||
|
the only LAN-connectivity for the Operations Console local console on a network
|
||
|
option for model 825.</div>
|
||
|
</td>
|
||
|
</tr>
|
||
|
</tbody>
|
||
|
</table>
|
||
|
</div>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div class="section"><div class="p">
|
||
|
<div class="tablenoborder"><img src="./delta.gif" alt="Start of change" /><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><caption>Table 3. iSeries requirements - LAN card location</caption><thead align="left"><tr><th valign="top" id="d0e197">Model</th>
|
||
|
<th valign="top" id="d0e199">Operations Console (LAN) console card location </th>
|
||
|
<th valign="top" id="d0e201">Operations Console direct connection (asynchronous)
|
||
|
location for the cable</th>
|
||
|
</tr>
|
||
|
</thead>
|
||
|
<tbody><tr><td valign="top" headers="d0e197 ">270</td>
|
||
|
<td valign="top" headers="d0e199 ">C06, second C05</td>
|
||
|
<td valign="top" headers="d0e201 ">C07</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e197 ">800, 810</td>
|
||
|
<td valign="top" headers="d0e199 ">C06, second C05</td>
|
||
|
<td valign="top" headers="d0e201 ">C07</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e197 ">820</td>
|
||
|
<td valign="top" headers="d0e199 ">C04, second C03, third C11</td>
|
||
|
<td valign="top" headers="d0e201 ">C06</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e197 ">825</td>
|
||
|
<td valign="top" headers="d0e199 ">Integrated Ethernet Port, (C03, C02, C01)<sup>(1)</sup></td>
|
||
|
<td valign="top" headers="d0e201 ">C06</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e197 ">830, SB2</td>
|
||
|
<td valign="top" headers="d0e199 ">C04, second C06, third C10</td>
|
||
|
<td valign="top" headers="d0e201 ">C02</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e197 ">840, SB3</td>
|
||
|
<td valign="top" headers="d0e199 ">C04, second C06, third C10</td>
|
||
|
<td valign="top" headers="d0e201 ">C02</td>
|
||
|
</tr>
|
||
|
<tr><td valign="top" headers="d0e197 ">870, 890</td>
|
||
|
<td valign="top" headers="d0e199 "> C04, C06, C07, C08, C09</td>
|
||
|
<td valign="top" headers="d0e201 ">C02</td>
|
||
|
</tr>
|
||
|
<tr><td colspan="3" valign="top" headers="d0e197 d0e199 d0e201 "><div class="note"><span class="notetitle">Note:</span> <sup>1</sup> These locations will
|
||
|
only be available if the Integrated Ethernet Port is not operational. </div>
|
||
|
</td>
|
||
|
</tr>
|
||
|
</tbody>
|
||
|
</table>
|
||
|
<img src="./deltaend.gif" alt="End of change" /></div>
|
||
|
</div>
|
||
|
<p>To review cable requirements, see the section: <a href="rzajrcables.htm#cables">Meet
|
||
|
Operations Console cable requirements</a>.</p>
|
||
|
</div>
|
||
|
</div>
|
||
|
<div>
|
||
|
<div class="familylinks">
|
||
|
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzajrverifyrequirements.htm" title="Use this information to verify that you have met all the hardware, software and cabling requirements for Operations Console.">Verify Operations Console requirements</a></div>
|
||
|
</div>
|
||
|
<div class="reltasks"><strong>Related tasks</strong><br />
|
||
|
<div><a href="rzajrmigrateiseries.htm" title="To change from an Operations Console with local console directly attached to a local console on a network (LAN), follow these steps on the server using the existing console.">Change the console from a local console directly attached to a local console on a network (LAN) in a non-partitioned or primary partitioned server</a></div>
|
||
|
<div><a href="rzajrmigrateiseries2.htm" title="To change from an Operations Console with a local console directly attached to a local console on a network (LAN), follow these steps on the server using the existing console.">Change the console from a local console directly attached to a local console on a network in a logical partition</a></div>
|
||
|
<div><a href="rzajrmigratingserver3.htm" title="To change from twinaxial to Operations Console, you must perform these steps on the server using the existing console.">Change the console from a twinaxial console to an Operations Console in a non-partitioned or primary partitioned server</a></div>
|
||
|
<div><a href="rzajrmigserver3.htm" title="To change from twinaxial to Operations Console, you must perform these steps on the server using the existing console prior to powering down or performing an initial program load (IPL).">Change the console from a twinaxial console to an Operations Console in a logical partition</a></div>
|
||
|
</div>
|
||
|
<div class="relref"><strong>Related reference</strong><br />
|
||
|
<div><a href="rzajrscenariothree.htm" title="A scenario that discusses a situation in which you want to manage multiple servers or partitions.">Scenario: Consoles for multiple servers or partitions</a></div>
|
||
|
<div><a href="rzajrminnetwork.htm" title="To prepare for your network environment, you need to identify and comply with the minimum network configuration required to set up an Operations Console local console on a network (LAN) configuration.">Prepare for your network environment</a></div>
|
||
|
<div><a href="rzajrcables.htm" title="You need to meet the following cable requirements for supported servers, cables and card locations.">Meet Operations Console cable requirements</a></div>
|
||
|
<div><a href="rzajrsoftwarereq.htm" title="You need to meet the following software requirements for working with Operations Console.">Meet Operations Console software requirements</a></div>
|
||
|
<div><a href="rzajrmigratingda.htm" title="To change from an Operations Console with a local console directly attached to a local console on a network (LAN), you must change settings on both the PC and the server.">Change from a local console directly attached to a local console on a network (LAN)</a></div>
|
||
|
<div><a href="rzajrmigratingtwinax.htm" title="To change from a twinaxial console to Operations Console, you a set of steps on both the PC and the server.">Change from a twinaxial console to Operations Console</a></div>
|
||
|
<div><a href="rzajrmigratingopscon.htm" title="To change from an Operations Console to a twinaxial console, you must perform steps on the server and, optionally, on the PC.">Changing from an Operations Console to a twinaxial console</a></div>
|
||
|