<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="Preparing your console for software installation" />
<meta name="abstract" content="Before you install a new software release, consider this information on consoles." />
<meta name="description" content="Before you install a new software release, consider this information on consoles." />
<meta name="DC.Relation" scheme="URI" content="requiredinitialinstall.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2004, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2004, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzahcswsdspport" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Preparing your console for software installation</title>
</head>
<body id="rzahcswsdspport"><a name="rzahcswsdspport"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Preparing your console for software installation</h1>
<div><p>Before you install a new software release, consider this information
on consoles.</p>
<div class="section"> <p>Although you can use twinaxial console on most servers, IBM recommends
for V5R4 that you use either Operations Console or Hardware Management Console.
For requirements on twinaxial console, Operations Console, and PCs, refer
to the category, <a href="../rzahg/rzahgicinterface.htm">Connecting
to iSeries</a> .
If you are moving from twinaxial console to Operations Console, use the <cite>iSeries
Setup and Operations CD-ROM, <span>SK3T-4098-02</span></cite>, to install Operations
Console before you install the new release. </p>
<p>If you are using twinaxial
console, the software installation process expects the system console device
to be attached at port 0 and address 0 of the first workstation controller.
In most cases, your hardware should be defined in this way. You should verify
that the console is attached at port 0 address 0.</p>
<p>If you are
planning on migrating your Operations Console, do so either before or after
you upgrade. If you are planning on migrating your Hardware Management Console
(HMC), do so only after you have completely installed your system. For more
information about using the HMC as your <span class="keyword">i5/OS™</span> console,
see <a href="../icbase/iphb7/i5osconsoles.htm" target="_blank">Managing <span class="keyword">i5/OS</span> consoles</a> .</p>
<p>For
all servers, verify that the console mode value is set correctly for your
console. In addition, you can specify that an i5/OS LAN console or Hardware Management
Console be taken over by another console in the event your console is disconnected.
To verify the console mode value, follow these steps:</p>
</div>
<ol><li class="stepexpand"><span>Access Dedicated Service Tools (DST).</span></li>
<li class="stepexpand"><span>Select <strong>Work with DST environment</strong>.</span></li>
<li class="stepexpand"><span>Select <strong>System Devices</strong>.</span></li>
<li class="stepexpand"><span>Select <strong>Console mode</strong>. </span> <p>The value of the current
console mode is present in the input field. Verify that this is the correct
setting. A value of zero means that the console mode has not been set and
can interfere with the automatic installation process. The console mode value
must be one of the following values.</p>
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><tbody><tr><td valign="top" width="16.751269035532996%">1</td>
<td valign="top" width="83.24873096446701%">Twinaxial console</td>
</tr>
<tr><td valign="top" width="16.751269035532996%">2</td>
<td valign="top" width="83.24873096446701%">Operations Console (directly attached)</td>
</tr>
<tr><td valign="top" width="16.751269035532996%">3</td>
<td valign="top" width="83.24873096446701%">Operations Console (LAN attached)</td>
</tr>
<tr><td valign="top" width="16.751269035532996%">4</td>
<td valign="top" width="83.24873096446701%">Hardware Management Console (HMC)</td>
</tr>
</tbody>
</table>
</div>
<p>During an installation or upgrade to V5R4, the console
type specified by this value is used. </p>
<p>The console mode display also
includes the option to allow your 5250 console (does not include twinaxial
console) to be taken over by another console. When this option is turned on,
the system does not stop with a failure but continues to run uninterrupted.
For more information, see the topic <a href="../icbase/iphbx/consoletakeoverandrecover.htm" target="_blank">Console takeover and recovery</a> .</p>
</li>
</ol>
<div class="section"> <div class="p">If you use Operations Console, do the following before you install <span>V5R4</span> on your server: <ul><li>Review the <a href="../rzajr/rzajropconoverview.htm">Operations
Console</a> topic. To review the most recent information on the Operations
Console client, go to the <a href="http://www.ibm.com/eserver/iseries/access/console/" target="_blank">Operations Console Web site</a> <img src="www.gif" alt="Link outside information center" /> </li>
<li>IBM recommends that you update IBM<sup>®</sup> eServer™ iSeries™ Access for Windows<sup>®</sup> to <span>V5R4</span> before you upgrade the <span class="keyword">i5/OS</span> operating
system. For more information, see <a href="../rzaij/rzaijrzaijinstall.htm">iSeries
Access for Windows: Installation and setup</a> .</li>
<li>If you use the Operations Console configuration, <samp class="codeph">Local
console directly attached to the server</samp>, and the adapter used for
the cable connection is 2771, the adapter must be in a specific position.
For independent or primary partitions only, the position is based on the server
model shown in the following table. <div class="note"><span class="notetitle">Note:</span> This applies only to <span class="keyword">iSeries</span> 270 and 8xx models. This does
not apply to <span>IBM <span class="keyword">System i5</span>,
System p5, and IBM eServer i5
and p5 systems</span>.</div>
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" class="singleborder" frame="border" border="1" rules="all"><caption>Table 1. Card position</caption><thead align="left"><tr class="tablemainheaderbar"><th valign="bottom" id="d0e185">Server model</th>
<th valign="bottom" id="d0e187">Operations Console asynchronous card position for the
cable</th>
</tr>
</thead>
<tbody><tr><td valign="top" headers="d0e185 ">270</td>
<td valign="top" headers="d0e187 ">C07</td>
</tr>
<tr><td valign="top" headers="d0e185 ">800 or 810</td>
<td valign="top" headers="d0e187 ">C07</td>
</tr>
<tr><td valign="top" headers="d0e185 ">820</td>
<td valign="top" headers="d0e187 ">C06</td>
</tr>
<tr><td valign="top" headers="d0e185 ">825</td>
<td valign="top" headers="d0e187 ">C06</td>
</tr>
<tr><td valign="top" headers="d0e185 ">830 or SB2</td>
<td valign="top" headers="d0e187 ">C02</td>
</tr>
<tr><td valign="top" headers="d0e185 ">840 or SB3</td>
<td valign="top" headers="d0e187 ">C02</td>
</tr>
<tr><td valign="top" headers="d0e185 ">870 or 890</td>
<td valign="top" headers="d0e187 ">C02</td>
</tr>
</tbody>
</table>
</div>
</li>
<li>When you receive the <span class="keyword">i5/OS</span> release
upgrade, the shipped service tools user IDs (except 11111111) are expired.
For all upgrades and installations, you need to establish a connection between <span>the
server and Operations Console PC by using</span> 11111111 (eight 1's) for both
the service tools user ID and the default password. This ensures a successful
authentication of the subsequent connection of the client to the server. This
is especially important for automatic installations.</li>
</ul>
</div>
<p>Failure to comply with the above actions can prevent the console
from working correctly during the upgrade or installation. </p>