ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzatm_5.4.0.1/rzatmcpdetails.htm

167 lines
9.0 KiB
HTML
Raw Permalink Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="concept" />
<meta name="DC.Title" content="Control panel buttons, lights, and indicators" />
<meta name="abstract" content="This information describes the interface for each type of control panel." />
<meta name="description" content="This information describes the interface for each type of control panel." />
<meta name="DC.Relation" scheme="URI" content="rzatmcpconcepts.htm" />
<meta name="DC.Relation" scheme="URI" content="rzatmphysicalcp.htm" />
<meta name="DC.Relation" scheme="URI" content="rzatmremotecp.htm" />
<meta name="DC.Relation" scheme="URI" content="rzatmvirtualcp.htm" />
<meta name="DC.Relation" scheme="URI" content="rzatmusingcontrolpanel.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 2000, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzatmcpdetails" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Control panel buttons, lights, and indicators</title>
</head>
<body id="rzatmcpdetails"><a name="rzatmcpdetails"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Control panel buttons, lights, and indicators</h1>
<div><p>This information describes the interface for each type of control
panel.</p>
<p>This topic describes the buttons, lights, and indicators for the control
panel. It also describes the interface for the virtual control panel and remote
control panel. The interface for the virtual control panel and remote control
panel are identical.</p>
<p>The following figures show:</p>
<ul><li>The remote control panel or virtual control panel</li>
<li>A control panel without a keystick</li>
<li>A control panel with a key stick</li>
</ul>
<div class="section"><h4 class="sectiontitle">Remote control panel and virtual control panel</h4><br /><img src="RZAH7512.GIF" alt="Remote control panel window" /><br />
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><tbody><tr><th valign="top" class="firstcol" id="d0e45">(A)</th>
<td valign="top" headers="d0e45 ">Function/Data display</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e50">(B)</th>
<td valign="top" headers="d0e50 ">Increment and Decrement buttons</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e55">(C)</th>
<td valign="top" headers="d0e55 ">Power on indicator</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e60">(D)</th>
<td valign="top" headers="d0e60 ">Power button</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e65">(E)</th>
<td valign="top" headers="d0e65 ">System Attention light</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e70">(F)</th>
<td valign="top" headers="d0e70 ">Enter button</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e75">(G)</th>
<td valign="top" headers="d0e75 ">Mode button</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="section"><h4 class="sectiontitle">Physical control panel without a keystick</h4><br /><img src="rv5b002.gif" alt="iSeries server control panel without a keystick" /><br />
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><tbody><tr><th valign="top" class="firstcol" id="d0e89">(A)</th>
<td valign="top" headers="d0e89 ">Power On Light <ul><li>A blinking light indicates power to the unit.</li>
<li>A constant light indicates that the unit is up and is working.</li>
</ul>
</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e99">(B)</th>
<td valign="top" headers="d0e99 ">Power button</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e104">(C)</th>
<td valign="top" headers="d0e104 ">Processor Activity</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e109">(D)</th>
<td valign="top" headers="d0e109 ">System Attention</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e114">(E)</th>
<td valign="top" headers="d0e114 ">Function/Data Display</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e119">(F)</th>
<td valign="top" headers="d0e119 ">Increment and Decrement buttons</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e124">(G)</th>
<td valign="top" headers="d0e124 ">Enter button</td>
</tr>
</tbody>
</table>
</div>
</div>
<div class="section"><h4 class="sectiontitle">Physical control panel with a keystick</h4><p>A keystick
gives the operator security control over the control panel functions and control
over data that is accessible from the control panel. The keystick for the
electronic keylock activates the Mode button.</p>
<br /><img src="rzacd507.gif" alt="iSeries server control panel with a keystick" /><br />
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><tbody><tr><th valign="top" class="firstcol" id="d0e140">(A)</th>
<td valign="top" headers="d0e140 ">Power On Light <ul><li>A blinking light indicates power to the unit.</li>
<li>A constant light indicates that the unit is up and is working.</li>
</ul>
</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e150">(B)</th>
<td valign="top" headers="d0e150 ">Power button</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e155">(C)</th>
<td valign="top" headers="d0e155 ">Processor Activity</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e160">(D)</th>
<td valign="top" headers="d0e160 ">System Attention</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e165">(E)</th>
<td valign="top" headers="d0e165 ">Function/Data Display</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e170">(F)</th>
<td valign="top" headers="d0e170 ">Increment and Decrement buttons</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e175">(G)</th>
<td valign="top" headers="d0e175 ">Enter button</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e180">(H)</th>
<td valign="top" headers="d0e180 ">Mode button</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e185">(J)</th>
<td valign="top" headers="d0e185 ">Electronic Keystick Slot</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e190">(K)</th>
<td valign="top" headers="d0e190 ">Secure</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e195">(L)</th>
<td valign="top" headers="d0e195 ">Auto</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e200">(M)</th>
<td valign="top" headers="d0e200 ">Normal</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e205">(N)</th>
<td valign="top" headers="d0e205 ">Manual</td>
</tr>
</tbody>
</table>
</div>
</div>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzatmcpconcepts.htm" title="This information explains the differences between control panel options. It also provides details about functions that the control panel can perform.">Control panel concepts</a></div>
</div>
<div class="relconcepts"><strong>Related concepts</strong><br />
<div><a href="rzatmphysicalcp.htm" title="The physical control panel is your initial interface with the iSeries server. You can use the physical control panel to perform functions such as IPL, power on, and power off. Control panel functions range in complexity from functions that display status (such as IPL speed) to low-level service functions that only service representatives must access.">Physical control panel</a></div>
<div><a href="rzatmremotecp.htm" title="The remote control panel is a way to use control panel functions through a PC. The graphical user interface of the remote control panel looks similar to the physical control panel.">Remote control panel</a></div>
<div><a href="rzatmvirtualcp.htm" title="The virtual control panel is an alternative to the remote control panel for parallel cable. Like the remote control panel, the virtual control panel is a way to use control panel functions through a PC.">Virtual control panel</a></div>
</div>
<div class="reltasks"><strong>Related tasks</strong><br />
<div><a href="rzatmusingcontrolpanel.htm" title="This information provides steps that explain how to access the control panel functions.">Access control panel functions</a></div>
</div>
</div>
</body>
</html>