ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzamd_5.4.0.1/rzamdexpanupgradecable.htm

106 lines
6.3 KiB
HTML
Raw Permalink Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE html
PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN" "http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html lang="en-us" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow" />
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<meta name="DC.Type" content="task" />
<meta name="DC.Title" content="SPD cabling" />
<meta name="abstract" content="During a model upgrade or an expansion unit conversion of a partitioned system (moving a partition from one server to another or changing an expansion unit from a 5065 to a 5074), an SPD bus may be removed." />
<meta name="description" content="During a model upgrade or an expansion unit conversion of a partitioned system (moving a partition from one server to another or changing an expansion unit from a 5065 to a 5074), an SPD bus may be removed." />
<meta name="DC.Relation" scheme="URI" content="rzamdplanexpanupgradelpar.htm" />
<meta name="DC.Relation" scheme="URI" content="rzamdplanexpanupgradelpar.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzamdexpanupgradecable" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>SPD cabling</title>
</head>
<body id="rzamdexpanupgradecable"><a name="rzamdexpanupgradecable"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">SPD cabling</h1>
<div><p>During a model upgrade or an expansion unit conversion of a partitioned
system (moving a partition from one server to another or changing an expansion
unit from a 5065 to a 5074), an SPD bus may be removed.</p>
<div class="section"><p>This has serious consequences to the LPAR configuration. SPD buses
are cabled in pairs and are numbered by the system on each IPL. This numbering
is done by determining to which port they are connected from the bus adapter.
When there are two buses connected to a bus adapter, the numbering of the
buses is determined as follows. A cable runs from the top port of the bus
adapter to the top port of the SPD bus; this is the first bus number. A cable
then runs from the bottom port of the SPD bus to the top port of the second
SPD bus; this is the next bus number. Finally, a cable runs back to the system
to complete the loop.</p>
<p>Due to the way these buses are cabled, they always
have the same bus number on each IPL. However, if the first bus is removed,
the second bus takes the bus number of the first bus. If both of these buses
are in the same partition, required LPAR configuration actions are minimal.
If the hardware in these buses is spread between different partitions or if
there is a required resource, for instance load source or console, LPAR configuration
actions must be taken before the partitions are powered on. The following
step should be performed any time an SPD bus is removed from a partitioned
system:</p>
</div>
<div class="p"><span>Determine if the bus to be removed will result in another bus being
renumbered. </span><ol type="a"><li><span>Use the following table to determine if the bus that will be
removed is cabled to the top or bottom port of the bus expansion adapter.</span></li>
<li><span>If the bus being removed is cabled to the <strong>bottom</strong> port
of the bus expansion adapter, then no buses are being recabled due to the
conversion of this tower.</span></li>
<li><span>If the bus being removed is cabled to the <strong>top</strong> port of
the bus expansion adapter, then determine if there is also a bus attached
to the bottom port (it will be one number higher than the bus being removed).
If there is a bus attached to the bottom port of the bus expansion adapter,
then there will be a bus recabled during this expansion unit conversion.</span></li>
</ol>
</div>
<div class="section">
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><thead align="left"><tr><th rowspan="2" valign="top" id="d0e48">iSeries™ server model</th>
<th colspan="2" valign="top" id="d0e52">Bus numbers</th>
</tr>
<tr><th valign="top" id="d0e55">Top port </th>
<th valign="top" id="d0e57">Bottom port </th>
</tr>
</thead>
<tbody><tr><td valign="top" headers="d0e48 ">720/620</td>
<td valign="top" headers="d0e52 d0e55 ">Odd</td>
<td valign="top" headers="d0e52 d0e57 ">Even</td>
</tr>
<tr><td valign="top" headers="d0e48 ">730/740/SX0</td>
<td valign="top" headers="d0e52 d0e55 ">Even</td>
<td valign="top" headers="d0e52 d0e57 ">Odd</td>
</tr>
<tr><td valign="top" headers="d0e48 ">820/830/840*</td>
<td valign="top" headers="d0e52 d0e55 ">Odd</td>
<td valign="top" headers="d0e52 d0e57 ">Even</td>
</tr>
</tbody>
</table>
</div>
<p>* Only applies to buses 5 through 22.</p>
<div class="note"><span class="notetitle">Example:</span> If bus 10 is to be removed on an iSeries Model 730 server, then bus 10
is cabled to the top port ("even" buses on an iSeries Model 730 server are attached
to the top port) so the system must be checked to determine whether a bus
11 is present.</div>
</div>
</div>
<div>
<div class="familylinks">
<div class="parentlink"><strong>Parent topic:</strong> <a href="rzamdplanexpanupgradelpar.htm" title="An expansion unit conversion causes the following changes to the server resources.">Plan to convert the expansion unit</a></div>
</div>
<div class="relconcepts"><strong>Related concepts</strong><br />
<div><a href="rzamdplanexpanupgradelpar.htm" title="An expansion unit conversion causes the following changes to the server resources.">Plan to convert the expansion unit</a></div>
</div>
</div>
</body>
</html>