<meta name="DC.Title" content="Restart system values: Maximum time for immediate shutdown" />
<meta name="abstract" content="Specifies the time limit before an immediate shutdown occurs. (QPWRDWNLMT)" />
<meta name="description" content="Specifies the time limit before an immediate shutdown occurs. (QPWRDWNLMT)" />
<meta name="DC.Relation" scheme="URI" content="rzakzqendjoblmt.htm" />
<meta name="DC.Relation" scheme="URI" content="rzakzrestartoverview.htm" />
<meta name="DC.Relation" scheme="URI" content="rzakzqendjoblmt.htm" />
<meta name="DC.Relation" scheme="URI" content="rzakzfinder.htm" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Rights.Owner" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="DC.Format" content="XHTML" />
<meta name="DC.Identifier" content="rzakzqpwrdwnlmt" />
<meta name="DC.Language" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<link rel="stylesheet" type="text/css" href="./ibmdita.css" />
<link rel="stylesheet" type="text/css" href="./ic.css" />
<title>Restart system values: Maximum time for immediate shutdown</title>
</head>
<body id="rzakzqpwrdwnlmt"><a name="rzakzqpwrdwnlmt"><!-- --></a>
<!-- Java sync-link --><script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<h1 class="topictitle1">Restart system values: Maximum time for immediate shutdown</h1>
<div><p>Specifies the time limit before an immediate shutdown occurs. (QPWRDWNLMT)</p>
<p><span class="uicontrol">Maximum time for immediate shutdown</span>, also known
as <span class="uicontrol">QPWRDWNLMT</span>, is a member of the restart category
of i5/OS™ system
values. You can use this system value to specify the time limit before an
immediate shutdown occurs. To learn more, keep reading.</p>
<div class="tablenoborder"><table cellpadding="4" cellspacing="0" summary="" frame="border" border="1" rules="all"><thead align="left"><tr><th colspan="2" valign="top" class="firstcol" id="d0e34">Quick reference</th>
</tr>
</thead>
<tbody><tr><th valign="top" class="firstcol" id="d0e38" headers="d0e34 ">Location</th>
<td valign="top" headers="d0e38 d0e34 ">In iSeries™ Navigator,
select your system, <span class="menucascade"><span class="uicontrol"></span> &gt; <span class="uicontrol">Configuration
and Service</span> &gt; <span class="uicontrol">System Values</span> &gt; <span class="uicontrol">Restart</span> &gt; <span class="uicontrol">General</span></span></td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e56" headers="d0e34 ">Special authority</th>
<td valign="top" headers="d0e56 d0e34 ">None</td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e61" headers="d0e34 ">Default value</th>
<td valign="top" headers="d0e61 d0e34 ">900 seconds </td>
</tr>
<tr><th valign="top" class="firstcol" id="d0e66" headers="d0e34 ">Changes take effect</th>
<td valign="top" headers="d0e66 d0e34 ">Immediately</td>
</tr>
</tbody>
</table>
</div>
<div class="section"><h4 class="sectiontitle">What can I do with this system value?</h4><p>Specifies
the maximum amount of time (in seconds) to wait for the system to power down
normally after a user has requested an immediate power-down or a user has
requested a controlled power-down and the time specified on the delay parameter
has expired. This time limit value is ignored when a user requests a power-down
after a power failure has occurred on a system with an uninterruptible power
supply.</p>
<p>If the value is set to 0 (or a very small value), a time-out
condition occurs, and the system does not finish the power-down operation
even though the system processing has ended.</p>
<p>In addition, this value
should be set to a value greater than the Maximum time for immediate end (QENDJOBLMT)
system value. To change the <span class="uicontrol">Maximum time for immediate end</span> system
value, select <span class="menucascade"><span class="uicontrol">Configuration and Service</span> &gt; <span class="uicontrol">System Values</span> &gt; <span class="uicontrol">Jobs</span></span>.
Then, select <span class="uicontrol">Cleanup</span>.</p>
</div>
<div class="section"><h4 class="sectiontitle">Where can I get more information about this system value?</h4><p>To
learn more, go to the restart system values overview topic. If you are looking
for a specific system value or category of system values, try using the i5/OS system
value finder.</p>
</div>
</div>
<div><div class="relconcepts"><strong>Related concepts</strong><br />
<div><a href="rzakzqendjoblmt.htm" title="Specifies the maximum amount of time for application cleanup during the immediate ending of a job. (QENDJOBLMT)">Jobs system values: Maximum time for immediate end</a></div>
<div><a href="rzakzrestartoverview.htm" title="Use restart system values to change and view when to restart the system and what will happen when the system is restarted.">System values: Restart overview</a></div>
</div>
<div class="relinfo"><strong>Related information</strong><br />
<div><a href="rzakzfinder.htm">System value finder</a></div>