ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzajt_5.4.0.1/rzajtrzajtcfg400tohostmcosrf.htm

81 lines
4.6 KiB
HTML
Raw Permalink Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Match iSeries system mode and class-of-service description parameters
for a host system</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="rzajt-cfg400tohostmcos-rf"></a>
<h4 id="rzajt-cfg400tohostmcos-rf">Match iSeries system mode and class-of-service description parameters
for a host system</h4>
<p>You must match host system communications configuration parameters with iSeries&trade; system values. A description of the iSeries system values are in the following
table. For information about configuring host systems, see the manuals <cite>VTAM&reg; Installation and Resource Definition</cite>, SC23-0111, and <cite>Network Control Program Resource Definition Reference</cite>, SC30-3254.</p>
<p>You can specify some host system parameters on multiple definition statements,
such as the GROUP, LINE, PU, and LU. The following table lists only the lowest
level definition statement that is used by the host system.</p>
<p>To configure an iSeries system to a host system:</p>
<ul>
<li>See <a href="rzajtrzajtcfg400tohostexre.htm#rzajt-cfg400tohostex-re">Examples: Connect iSeries server to a host server</a> for an example of connecting
an iSeries system to a host system.</li>
<li>Use the following table for the mode and class-of-service description
parameter.</li></ul>
<a name="wq33"></a>
<table id="wq33" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
<thead valign="bottom">
<tr>
<th id="wq34" width="19%" align="center" valign="bottom">iSeries Prompt</th>
<th id="wq35" width="15%" align="center" valign="bottom">iSeries Parameter</th>
<th id="wq36" width="15%" align="center" valign="bottom">Host Definition Statement</th>
<th id="wq37" width="50%" align="center" valign="bottom">Host Parameter</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td align="left" valign="top" headers="wq34">Mode description name</td>
<td align="left" valign="top" headers="wq35">MODD</td>
<td align="left" valign="top" headers="wq36">MODEENT</td>
<td align="left" valign="top" headers="wq37">LOGMODE
<p>iSeries mode description name specified on
the iSeries CRTMODD command (MODD parameter) must be defined in the host
logon mode table using the LOGMODE parameter on the MODEENT macro instruction.
The mode name must also be included in the CICS/VS terminal control table
(DFHTCT) MODENAM parameter.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq34">Class-of-service description name</td>
<td align="left" valign="top" headers="wq35">COSD</td>
<td align="left" valign="top" headers="wq36">MODEENT</td>
<td align="left" valign="top" headers="wq37">COS
<p>iSeries class-of-service description name specified
on the iSeries Create Class-of-Service Description (CRTCOSD) command (COSD parameter)
and CRTMODD command (COS parameter) must be defined in the host logon mode
table using the COS parameter on the MODEENT macro instruction. The class-of-service
description must also be defined in the VTAM class-of-service table.</p></td>
</tr>
</tbody>
</table>
<p>For more information on iSeries system parameters, see <a href="../books/c4154010.pdf" target="_blank">Communications Configuration</a>
<img src="wbpdf.gif" alt="Link to PDF" />.</p>
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
</body>
</html>