ibm-information-center/dist/eclipse/plugins/i5OS.ic.rzajt_5.4.0.1/rzajtrzajtcfg400to5494sdrf.htm

175 lines
8.9 KiB
HTML
Raw Permalink Normal View History

2024-04-02 14:02:31 +00:00
<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
<meta name="dc.language" scheme="rfc1766" content="en-us" />
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
<meta name="security" content="public" />
<meta name="Robots" content="index,follow"/>
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
<title>Match iSeries system parameters for a 5494 connected by SDLC</title>
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
<link rel="stylesheet" type="text/css" href="ic.css" />
</head>
<body>
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
<a name="rzajt-cfg400to5494sd-rf"></a>
<h4 id="rzajt-cfg400to5494sd-rf">Match iSeries system parameters for a 5494 connected by SDLC</h4>
<p>You must coordinate communications configuration parameters between the iSeries&trade; system and the 5494 controller that is connected by <a href="rzajtrzajtsdlccon.htm#rzajtsdlc-con">SDLC</a>. These parameters are described in the following table. Then the
related fields and subfields from the 5494 configuration display are listed
next. These values are followed by the iSeries configuration value and the matching
5494 value to be entered in the display subfield. You can coordinate these
values automatically or manually. Pick one of these ways:</p>
<ul>
<li>To automatically connect the iSeries server to a 5494 controller, you can
use the automatic remote controller (QAUTORMT) system value.</li>
<li>To manually connect the iSeries server to a 5494 controller, use the
following table.</li></ul>
<p>For more information about configuring the 5494, see these books:</p>
<ul>
<li><cite>IBM&reg; 5494 Remote Control Unit Planning Guide</cite>, GA27-3936</li>
<li><cite>IBM 5494 Remote Control Unit User's Guide</cite>, GA27-3852</li></ul>
<a name="wq85"></a>
<table id="wq85" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
<thead valign="bottom">
<tr>
<th id="wq86" width="10%" align="center" valign="bottom">iSeries Prompt</th>
<th id="wq87" width="16%" align="center" valign="bottom">iSeries Parameter</th>
<th id="wq88" width="8%" align="center" valign="bottom">5494 Field</th>
<th id="wq89" width="9%" align="left">5494 Subfield</th>
<th id="wq90" width="16%" align="center" valign="bottom">iSeries Value</th>
<th id="wq91" width="10%" align="center" valign="bottom">5494 Value</th>
<th id="wq92" width="28%" align="center" valign="bottom">Notes</th>
</tr>
</thead>
<tbody valign="top">
<tr>
<td rowspan="4" align="left" valign="top" headers="wq86">Connection type</td>
<td rowspan="4" align="left" valign="top" headers="wq87">CNN</td>
<td rowspan="4" align="center" valign="top" headers="wq88">3</td>
<td rowspan="2" align="center" valign="top" headers="wq89">1</td>
<td align="left" valign="top" headers="wq90">*NONSWTPP *MP</td>
<td align="center" valign="top" headers="wq91">0</td>
<td rowspan="4" align="left" valign="top" headers="wq92"></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq90">*SWTPP</td>
<td align="center" valign="top" headers="wq91">1</td>
</tr>
<tr>
<td rowspan="2" align="center" valign="top" headers="wq89">3</td>
<td align="left" valign="top" headers="wq90">*MP</td>
<td align="center" valign="top" headers="wq91">0</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq90">*NONSWTPP *SWTPP</td>
<td align="center" valign="top" headers="wq91">1</td>
</tr>
<tr>
<td rowspan="2" align="left" valign="top" headers="wq86">Duplex</td>
<td rowspan="2" align="left" valign="top" headers="wq87">Duplex</td>
<td rowspan="2" align="center" valign="top" headers="wq88">3</td>
<td rowspan="2" align="center" valign="top" headers="wq89">2</td>
<td align="left" valign="top" headers="wq90">*HALF</td>
<td align="center" valign="top" headers="wq91">0</td>
<td rowspan="2" align="left" valign="top" headers="wq92"></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq90">*FULL</td>
<td align="center" valign="top" headers="wq91">1</td>
</tr>
<tr>
<td rowspan="2" align="left" valign="top" headers="wq86">NRZI data encoding</td>
<td rowspan="2" align="left" valign="top" headers="wq87">NRZI</td>
<td rowspan="2" align="center" valign="top" headers="wq88">3</td>
<td rowspan="2" align="center" valign="top" headers="wq89">4</td>
<td align="left" valign="top" headers="wq90">*YES</td>
<td align="center" valign="top" headers="wq91">0</td>
<td rowspan="2" align="left" valign="top" headers="wq92"></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq90">*NO</td>
<td align="center" valign="top" headers="wq91">1</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq86">Local location name</td>
<td align="left" valign="top" headers="wq87">LCLLOCNAME</td>
<td align="center" valign="top" headers="wq88">H1</td>
<td align="center" valign="top" headers="wq89">1</td>
<td align="left" valign="top" headers="wq90">-</td>
<td align="center" valign="top" headers="wq91">-</td>
<td align="left" valign="top" headers="wq92">Values specified for the iSeries CRTCTLRWS
command and for the 5494 Remote Control Unit must match.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq86">Link type</td>
<td align="left" valign="top" headers="wq87">LINKTYPE</td>
<td align="left" valign="top" headers="wq88">AA</td>
<td align="center" valign="top" headers="wq89">-</td>
<td align="left" valign="top" headers="wq90">*SDLC</td>
<td align="center" valign="top" headers="wq91">0,2,3</td>
<td align="left" valign="top" headers="wq92">5494 configuration values must match the
values specified for the LINKTYPE parameter on the CRTCTLAPPC command. For
APPC controllers that specify LINKTYPE(*SDLC), the value specified in the
5494 configuration must be compatible with the physical interface (INTERFACE
parameter) specified on the CRTLINSDLC command.
<p>Select 0 for communications
using SDLC lines other than X.21 connections.</p></td>
</tr>
<tr>
<td align="left" valign="top" headers="wq86">Remote control point name</td>
<td align="left" valign="top" headers="wq87">RMTCPNAME</td>
<td align="center" valign="top" headers="wq88">13</td>
<td align="center" valign="top" headers="wq89">-</td>
<td align="left" valign="top" headers="wq90">-</td>
<td align="center" valign="top" headers="wq91">-</td>
<td align="left" valign="top" headers="wq92">Values specified for the iSeries CRTCTLAPPC
command and for the 5494 Remote Control Unit must match.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq86">Remote network identifier</td>
<td align="left" valign="top" headers="wq87">RMTNETID</td>
<td align="center" valign="top" headers="wq88">11</td>
<td align="center" valign="top" headers="wq89">3</td>
<td align="left" valign="top" headers="wq90">-</td>
<td align="center" valign="top" headers="wq91">-</td>
<td align="left" valign="top" headers="wq92">Values specified for the iSeries CRTCTLAPPC
and CRTCTLRWS commands and for the 5494 Remote Control Unit must match.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq86">Remote location name</td>
<td align="left" valign="top" headers="wq87">RMTLOCNAME</td>
<td align="center" valign="top" headers="wq88">12</td>
<td align="center" valign="top" headers="wq89">-</td>
<td align="left" valign="top" headers="wq90">-</td>
<td align="center" valign="top" headers="wq91">-</td>
<td align="left" valign="top" headers="wq92">Values specified for the iSeries CRTCTLRWS
command and for the 5494 Remote Control Unit must match.</td>
</tr>
<tr>
<td align="left" valign="top" headers="wq86">Station address</td>
<td align="left" valign="top" headers="wq87">STNADR</td>
<td align="center" valign="top" headers="wq88">2</td>
<td align="center" valign="top" headers="wq89">-</td>
<td align="left" valign="top" headers="wq90">-</td>
<td align="center" valign="top" headers="wq91">-</td>
<td align="left" valign="top" headers="wq92">Values specified in the iSeries controller
description and for the 5494 Remote Control Unit must match. This value must
also be specified as the last 2 digits of the iSeries EXCHID parameter.</td>
</tr>
</tbody>
</table>
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
</body>
</html>