192 lines
10 KiB
HTML
192 lines
10 KiB
HTML
|
<?xml version="1.0" encoding="utf-8"?>
|
||
|
<!DOCTYPE html PUBLIC "-//W3C//DTD XHTML 1.0 Transitional//EN"
|
||
|
"http://www.w3.org/TR/xhtml1/DTD/xhtml1-transitional.dtd">
|
||
|
<html xmlns="http://www.w3.org/1999/xhtml" lang="en-US" xml:lang="en-us">
|
||
|
<head>
|
||
|
<meta http-equiv="Content-Type" content="text/html; charset=utf-8" />
|
||
|
<meta name="dc.language" scheme="rfc1766" content="en-us" />
|
||
|
<!-- All rights reserved. Licensed Materials Property of IBM -->
|
||
|
<!-- US Government Users Restricted Rights -->
|
||
|
<!-- Use, duplication or disclosure restricted by -->
|
||
|
<!-- GSA ADP Schedule Contract with IBM Corp. -->
|
||
|
<meta name="dc.date" scheme="iso8601" content="2005-09-06" />
|
||
|
<meta name="copyright" content="(C) Copyright IBM Corporation 1998, 2006" />
|
||
|
<meta name="security" content="public" />
|
||
|
<meta name="Robots" content="index,follow"/>
|
||
|
<meta http-equiv="PICS-Label" content='(PICS-1.1 "http://www.icra.org/ratingsv02.html" l gen true r (cz 1 lz 1 nz 1 oz 1 vz 1) "http://www.rsac.org/ratingsv01.html" l gen true r (n 0 s 0 v 0 l 0) "http://www.classify.org/safesurf/" l gen true r (SS~~000 1))' />
|
||
|
<title>Match iSeries system line description parameters for a remote iSeries system</title>
|
||
|
<link rel="stylesheet" type="text/css" href="ibmidwb.css" />
|
||
|
<link rel="stylesheet" type="text/css" href="ic.css" />
|
||
|
</head>
|
||
|
<body>
|
||
|
<a id="Top_Of_Page" name="Top_Of_Page"></a><!-- Java sync-link -->
|
||
|
<script language = "Javascript" src = "../rzahg/synch.js" type="text/javascript"></script>
|
||
|
|
||
|
|
||
|
<a name="rzajt-cfg400to400lin-rf"></a>
|
||
|
<h3 id="rzajt-cfg400to400lin-rf">Match iSeries system line description parameters for a remote iSeries system</h3>
|
||
|
<p>You must coordinate communications configuration parameters between local
|
||
|
and remote iSeries™ systems. These parameters are described in the following table.
|
||
|
This table shows those prompts and parameters that must be coordinated when
|
||
|
you specify line descriptions for the local and remote iSeries systems.</p>
|
||
|
<p>To configure a local iSeries server to a remote iSeries server:</p>
|
||
|
<ul>
|
||
|
<li>See <a href="rzajtrzajtcfg400to400exre.htm#rzajt-cfg400to400ex-re">Connect one iSeries server to another iSeries server</a> for an example of connecting
|
||
|
one iSeries server to another iSeries server.</li>
|
||
|
<li>Use the following table for the line descriptions.</li></ul>
|
||
|
<a name="wq43"></a>
|
||
|
<table id="wq43" width="100%" summary="" border="1" frame="border" rules="all" class="singleborder">
|
||
|
<thead valign="bottom">
|
||
|
<tr>
|
||
|
<th id="wq44" width="20%" align="center" valign="bottom">iSeries system Prompt</th>
|
||
|
<th id="wq45" width="14%" align="center" valign="bottom">iSeries Parameter</th>
|
||
|
<th id="wq46" width="14%" align="center" valign="bottom">Remote iSeries Parameter</th>
|
||
|
<th id="wq47" width="49%" align="center" valign="bottom">Notes</th>
|
||
|
</tr>
|
||
|
</thead>
|
||
|
<tbody valign="top">
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Local adapter address</td>
|
||
|
<td align="left" valign="top" headers="wq45">ADPTADR</td>
|
||
|
<td align="left" valign="top" headers="wq46">ADPTADR</td>
|
||
|
<td align="left" valign="top" headers="wq47">Adapter address of the local system (specified
|
||
|
on the line description) must be matched at the remote system in the controller
|
||
|
description ADPTADR parameter.
|
||
|
<p>If the iSeries system uses an Ethernet line through
|
||
|
an 8209 LAN Bridge, see "Appendix C: Local Area Network Addressing Considerations"
|
||
|
in the Communications Configuration</p>book.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Insert network address in packets</td>
|
||
|
<td align="left" valign="top" headers="wq45">ADRINSERT</td>
|
||
|
<td align="left" valign="top" headers="wq46">ADRINSERT</td>
|
||
|
<td align="left" valign="top" headers="wq47">If X.25 DCE support is specified (X25DCE(*YES)
|
||
|
or X25DCE(*NEG)), ADRINSERT(*YES) should be specified for both systems.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Data bits per character</td>
|
||
|
<td align="left" valign="top" headers="wq45">BITSCHAR</td>
|
||
|
<td align="left" valign="top" headers="wq46">BITSCHAR</td>
|
||
|
<td align="left" valign="top" headers="wq47">Values specified for each system must match.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Connection initiation</td>
|
||
|
<td align="left" valign="top" headers="wq45">CNNINIT</td>
|
||
|
<td align="left" valign="top" headers="wq46">CNNINIT</td>
|
||
|
<td align="left" valign="top" headers="wq47">If X.25 DCE support is specified (X25DCE(*YES))
|
||
|
for either system, CNNINIT(*LOCAL) should also be specified on that system's
|
||
|
line description. The other system (with X25DCE(*NO) specified) should specify
|
||
|
CNNINIT(*REMOTE) or CNNINIT(*WAIT).
|
||
|
<p>For switched connections, both systems
|
||
|
can also specify X25DCE(*NEG) to negotiate the Distributed Computing Environment
|
||
|
(DCE) and data terminal equipment (DTE) roles and CNNINIT(*CALLER) to allow
|
||
|
either system to initiate the connection by making the call.</p>
|
||
|
<p>See the
|
||
|
X25DCE parameter for additional considerations.</p></td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Duplex</td>
|
||
|
<td align="left" valign="top" headers="wq45">DUPLEX</td>
|
||
|
<td align="left" valign="top" headers="wq46">DUPLEX</td>
|
||
|
<td align="left" valign="top" headers="wq47">Depending on the type of communications used,
|
||
|
the values specified for the DUPLEX parameters may need to be coordinated.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Ethernet standard</td>
|
||
|
<td align="left" valign="top" headers="wq45">ETHSTD</td>
|
||
|
<td align="left" valign="top" headers="wq46">ETHSTD</td>
|
||
|
<td align="left" valign="top" headers="wq47">Values specified for each system must be
|
||
|
coordinated. Both systems must specify the same standard (*ETHV2 or *IEEE8023)
|
||
|
or at least one system must specify *ALL.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Exchange identifier</td>
|
||
|
<td align="left" valign="top" headers="wq45">EXCHID</td>
|
||
|
<td align="left" valign="top" headers="wq46">EXCHID</td>
|
||
|
<td align="left" valign="top" headers="wq47">Remote iSeries controller description EXCHID must
|
||
|
match the local iSeries line description EXCHID. The first three digits
|
||
|
of the exchange identifier, known as the block number, is <tt class="xph">056</tt> for
|
||
|
the iSeries line. You can use the Work with Line Descriptions (WRKLIND)
|
||
|
command to determine this value.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Logical channel entries</td>
|
||
|
<td align="left" valign="top" headers="wq45">LGLCHLE</td>
|
||
|
<td align="left" valign="top" headers="wq46">LGLCHLE</td>
|
||
|
<td align="left" valign="top" headers="wq47">If X.25 DCE support is specified (X25DCE(*YES)
|
||
|
or X25DCE(*NEG)), logical channel types and channel numbers must be coordinated.
|
||
|
See also the considerations for the X25DCE parameter.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Line speed</td>
|
||
|
<td align="left" valign="top" headers="wq45">LINESPEED</td>
|
||
|
<td align="left" valign="top" headers="wq46">LINESPEED</td>
|
||
|
<td align="left" valign="top" headers="wq47">For asynchronous lines, the line speeds specified
|
||
|
for each system must match.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Modulus</td>
|
||
|
<td align="left" valign="top" headers="wq45">MODULUS</td>
|
||
|
<td align="left" valign="top" headers="wq46">MODULUS</td>
|
||
|
<td align="left" valign="top" headers="wq47">If X.25 DCE support is specified (X25DCE(*YES)
|
||
|
or X25DCE(*NEG)), modulus values specified for each system must match.
|
||
|
<p>The values specified for this parameter should match for all communications
|
||
|
types.</p></td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Local network address</td>
|
||
|
<td align="left" valign="top" headers="wq45">NETADR</td>
|
||
|
<td align="left" valign="top" headers="wq46">CNNNBR</td>
|
||
|
<td align="left" valign="top" headers="wq47">For switched virtual circuits (SVCs), the
|
||
|
NETADR parameter on the local system line description must match the CNNNBR
|
||
|
parameter on the <span class="italic">controller description</span> for the remote
|
||
|
system.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">NRZI data encoding</td>
|
||
|
<td align="left" valign="top" headers="wq45">NRZI</td>
|
||
|
<td align="left" valign="top" headers="wq46">NRZI</td>
|
||
|
<td align="left" valign="top" headers="wq47">Values specified for each system must match
|
||
|
(*YES or *NO).</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Data link role</td>
|
||
|
<td align="left" valign="top" headers="wq45">ROLE</td>
|
||
|
<td align="left" valign="top" headers="wq46">ROLE</td>
|
||
|
<td align="left" valign="top" headers="wq47">The value specified for the local system
|
||
|
line description ROLE parameter should match the controller description ROLE
|
||
|
parameter specified at the remote system.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Number of stop bits</td>
|
||
|
<td align="left" valign="top" headers="wq45">STOPBITS</td>
|
||
|
<td align="left" valign="top" headers="wq46">STOPBITS</td>
|
||
|
<td align="left" valign="top" headers="wq47">Values specified for each system must match.</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">Switched connection type</td>
|
||
|
<td align="left" valign="top" headers="wq45">SWTCNN</td>
|
||
|
<td align="left" valign="top" headers="wq46">SWTCNN</td>
|
||
|
<td align="left" valign="top" headers="wq47">Values specified for each system must be
|
||
|
compatible. (*DIAL or *ANS must not be specified for <span class="italic">both</span> systems.)</td>
|
||
|
</tr>
|
||
|
<tr>
|
||
|
<td align="left" valign="top" headers="wq44">X.25 DCE support</td>
|
||
|
<td align="left" valign="top" headers="wq45">X25DCE</td>
|
||
|
<td align="left" valign="top" headers="wq46">X25DCE</td>
|
||
|
<td align="left" valign="top" headers="wq47">If X.25 DCE support is used (X25DCE(*YES)),
|
||
|
only one of the iSeries line descriptions should specify *YES. The system
|
||
|
specifying X25DCE(*YES) should also specify CNNINIT(*LOCAL); the other iSeries server should specify X25DCE(*NO) and CNNINIT(*REMOTE) or CNNINIT(*WAIT).
|
||
|
<p>For switched connections, both systems can also specify X25DCE(*NEG) to negotiate
|
||
|
the DCE and DTE roles, and CNNINIT(*CALLER) to allow either system to initiate
|
||
|
the connection by making the call.</p></td>
|
||
|
</tr>
|
||
|
</tbody>
|
||
|
</table>
|
||
|
<p>For more information on iSeries system parameters, see the <a href="../books/c4154010.pdf" target="_blank">Communications Configuration</a>
|
||
|
<img src="wbpdf.gif" alt="Link to PDF" /> book.</p>
|
||
|
<p>For steps on how to create a line description, see <a href="rzajtrzajtlinpi.htm#rzajtlin-pi">Create a line description</a>.</p>
|
||
|
<a id="Bot_Of_Page" name="Bot_Of_Page"></a>
|
||
|