<td valign="top" align="left"><b>Where allowed to run: </b>All environments (*ALL)<br>
<b>Threadsafe: </b>No
</td>
<td valign="top" align="right">
<a href="#CRTLINX25.PARAMETERS.TABLE">Parameters</a><br>
<a href="#CRTLINX25.COMMAND.EXAMPLES">Examples</a><br>
<a href="#CRTLINX25.ERROR.MESSAGES">Error messages</a></td>
</tr>
</table>
<div> <a name="CRTLINX25"></a>
<p>The Create Line Description (X.25) (CRTLINX25) command creates a line description for an X.25 line.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div>
<h3><a name="CRTLINX25.PARAMETERS.TABLE">Parameters</a></h3>
<table border="1" cellpadding="4" cellspacing="0">
<!-- col1="10" col2="15" col3="30" col4="10" -->
<tr>
<th bgcolor="aqua" valign="bottom" align="left">Keyword</th>
<th bgcolor="aqua" valign="bottom" align="left">Description</th>
<th bgcolor="aqua" valign="bottom" align="left">Choices</th>
<th bgcolor="aqua" valign="bottom" align="left">Notes</th>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.LIND"><b>LIND</b></a></td>
<td valign="top">Line description</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Required, Positional 1</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.RSRCNAME"><b>RSRCNAME</b></a></td>
<td valign="top">Resource name</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Required, Positional 2</td>
</tr>
<tr>
<td valign="top" rowspan="4"><a href="#CRTLINX25.LGLCHLE"><b>LGLCHLE</b></a></td>
<td valign="top">Logical channel entries</td>
<td valign="top">Single values: *PROMPT<br>Other values (up to 256 repetitions): <i>Element list</i></td>
<td valign="top" rowspan="4">Required, Positional 3</td>
</tr>
<tr>
<td valign="top">Element 1: Logical channel identifier</td>
<td valign="top">
<i>Character value</i></td>
</tr>
<tr>
<td valign="top">Element 2: Logical channel type</td>
<td valign="top">
*PVC, *SVCIN, *SVCBOTH, *SVCOUT</td>
</tr>
<tr>
<td valign="top">Element 3: PVC controller</td>
<td valign="top">
<i>Name</i></td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.NETADR"><b>NETADR</b></a></td>
<td valign="top">Local network address</td>
<td valign="top"><i>Character value</i></td>
<td valign="top">Required, Positional 4</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CNNINIT"><b>CNNINIT</b></a></td>
<td valign="top">Connection initiation</td>
<td valign="top">*LOCAL, *REMOTE, *WAIT, *CALLER</td>
<td valign="top">Required, Positional 5</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.ONLINE"><b>ONLINE</b></a></td>
<td valign="top">Online at IPL</td>
<td valign="top"><b><u>*YES</u></b>, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.INTERFACE"><b>INTERFACE</b></a></td>
<td valign="top">Physical interface</td>
<td valign="top"><b><u>*X21BISV24</u></b>, *X21BISV35, *RS232V24, *RS449V36, *X21, *INTMODEM</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CNN"><b>CNN</b></a></td>
<td valign="top">Connection type</td>
<td valign="top"><b><u>*NONSWTPP</u></b>, *SWTPP, *NONSWTCAL, *NONSWTANS</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.NWI"><b>NWI</b></a></td>
<td valign="top">Attached nonswitched NWI</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.NWICHLTYPE"><b>NWICHLTYPE</b></a></td>
<td valign="top">NWI channel type</td>
<td valign="top"><b><u>*B</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.NWICHLNBR"><b>NWICHLNBR</b></a></td>
<td valign="top">NWI channel number</td>
<td valign="top">1-30</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top" rowspan="4"><a href="#CRTLINX25.SWTNWILST"><b>SWTNWILST</b></a></td>
<td valign="top">Switched NWI list</td>
<td valign="top">Single values: <b><u>*NONE</u></b><br>Other values (up to 64 repetitions): <i>Element list</i></td>
<td valign="top" rowspan="4">Optional</td>
</tr>
<tr>
<td valign="top">Element 1: NWI description</td>
<td valign="top">
<i>Name</i></td>
</tr>
<tr>
<td valign="top">Element 2: NWI channel type</td>
<td valign="top">
<b><u>*B</u></b></td>
</tr>
<tr>
<td valign="top">Element 3: NWI channel number</td>
<td valign="top">
1-30, <b><u>*CALC</u></b></td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.VRYWAIT"><b>VRYWAIT</b></a></td>
<td valign="top">Vary on wait</td>
<td valign="top">15-180, <b><u>*NOWAIT</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.LINESPEED"><b>LINESPEED</b></a></td>
<td valign="top">Line speed</td>
<td valign="top">*CALC, 600, 1200, 2400, 4800, 7200, <b><u>9600</u></b>, 12000, 14400, 19200, 48000, 56000, 57600, 64000, 128000, 192000, 256000, 320000, 384000, 448000, 512000, 576000, 640000, 704000, 768000, 832000, 896000, 960000, 1024000, 1088000, 1152000, 1216000, 1280000, 1344000, 1408000, 1472000, 1536000, 1600000, 1664000, 1728000, 1792000, 1856000, 1920000, 1984000, 2048000</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.EXCHID"><b>EXCHID</b></a></td>
<td valign="top">Exchange identifier</td>
<td valign="top">05600000-056FFFFF, <b><u>*SYSGEN</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.PKTMODE"><b>PKTMODE</b></a></td>
<td valign="top">Packet mode</td>
<td valign="top">*YES, <b><u>*NO</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.INFTRFTYPE"><b>INFTRFTYPE</b></a></td>
<td valign="top">Information transfer type</td>
<td valign="top"><b><u>*UNRESTRICTED</u></b>, *V110, *DOV, *SYNCMODEM</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.EXNNETADR"><b>EXNNETADR</b></a></td>
<td valign="top">Extended network addressing</td>
<td valign="top">*YES, <b><u>*NO</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.MAXFRAME"><b>MAXFRAME</b></a></td>
<td valign="top">Maximum frame size</td>
<td valign="top"><b><u>1024</u></b>, 2048, 4096</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CRTLINX25.DFTPKTSIZE"><b>DFTPKTSIZE</b></a></td>
<td valign="top">Default packet size</td>
<td valign="top"><i>Element list</i></td>
<td valign="top" rowspan="3">Optional</td>
</tr>
<tr>
<td valign="top">Element 1: Transmit value</td>
<td valign="top">
64, <b><u>128</u></b>, 256, 512, 1024, 2048, 4096</td>
</tr>
<tr>
<td valign="top">Element 2: Receive value</td>
<td valign="top">
<b><u>*TRANSMIT</u></b>, 64, 128, 256, 512, 1024, 2048, 4096</td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CRTLINX25.MAXPKTSIZE"><b>MAXPKTSIZE</b></a></td>
<td valign="top">Maximum packet size</td>
<td valign="top"><i>Element list</i></td>
<td valign="top" rowspan="3">Optional</td>
</tr>
<tr>
<td valign="top">Element 1: Transmit value</td>
<td valign="top">
<b><u>*DFTPKTSIZE</u></b>, 64, 128, 256, 512, 1024, 2048, 4096</td>
</tr>
<tr>
<td valign="top">Element 2: Receive value</td>
<td valign="top">
*DFTPKTSIZE, <b><u>*TRANSMIT</u></b>, 64, 128, 256, 512, 1024, 2048, 4096</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.MODULUS"><b>MODULUS</b></a></td>
<td valign="top">Modulus</td>
<td valign="top"><b><u>8</u></b>, 128</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CRTLINX25.DFTWDWSIZE"><b>DFTWDWSIZE</b></a></td>
<td valign="top">Default window size</td>
<td valign="top"><i>Element list</i></td>
<td valign="top" rowspan="3">Optional</td>
</tr>
<tr>
<td valign="top">Element 1: Transmit value</td>
<td valign="top">
1-15, <b><u>2</u></b></td>
</tr>
<tr>
<td valign="top">Element 2: Receive value</td>
<td valign="top">
1-15, <b><u>*TRANSMIT</u></b></td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.ADRINSERT"><b>ADRINSERT</b></a></td>
<td valign="top">Insert net address in packets</td>
<td valign="top"><b><u>*YES</u></b>, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.NETUSRID"><b>NETUSRID</b></a></td>
<td valign="top">Network user ID</td>
<td valign="top"><i>Character value</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CNNNBR"><b>CNNNBR</b></a></td>
<td valign="top">Connection number</td>
<td valign="top"><i>Character value</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CALLNBR"><b>CALLNBR</b></a></td>
<td valign="top">Calling number</td>
<td valign="top"><i>Character value</i>, <b><u>*NONE</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.SWTCNN"><b>SWTCNN</b></a></td>
<td valign="top">Switched connection type</td>
<td valign="top"><b><u>*BOTH</u></b>, *ANS, *DIAL</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CNNLSTOUT"><b>CNNLSTOUT</b></a></td>
<td valign="top">Outgoing connection list</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CNNLSTOUTE"><b>CNNLSTOUTE</b></a></td>
<td valign="top">Connection list entry</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CNNLSTIN"><b>CNNLSTIN</b></a></td>
<td valign="top">Incoming connection list</td>
<td valign="top"><i>Name</i>, <b><u>*NETATR</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.AUTOANS"><b>AUTOANS</b></a></td>
<td valign="top">Autoanswer</td>
<td valign="top"><b><u>*YES</u></b>, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.AUTODIAL"><b>AUTODIAL</b></a></td>
<td valign="top">Autodial</td>
<td valign="top"><b><u>*NO</u></b>, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.DIALCMD"><b>DIALCMD</b></a></td>
<td valign="top">Dial command type</td>
<td valign="top"><b><u>*NONE</u></b>, *V25BIS</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.MDMINZCMD"><b>MDMINZCMD</b></a></td>
<td valign="top">Modem init command string</td>
<td valign="top"><i>Character value</i>, <b><u>*NONE</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CALLIMMED"><b>CALLIMMED</b></a></td>
<td valign="top">Call immediate</td>
<td valign="top"><b><u>*NO</u></b>, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.AUTOCALL"><b>AUTOCALL</b></a></td>
<td valign="top">Autocall unit</td>
<td valign="top"><b><u>*NO</u></b>, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.ACRSRCNAME"><b>ACRSRCNAME</b></a></td>
<td valign="top">Autocall resource name</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.PREDIALDLY"><b>PREDIALDLY</b></a></td>
<td valign="top">Predial delay</td>
<td valign="top">0-254, <b><u>6</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.REDIALDLY"><b>REDIALDLY</b></a></td>
<td valign="top">Redial delay</td>
<td valign="top">0-254, <b><u>120</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.DIALRTY"><b>DIALRTY</b></a></td>
<td valign="top">Dial retry</td>
<td valign="top">0-254, <b><u>2</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.SWTDSC"><b>SWTDSC</b></a></td>
<td valign="top">Switched disconnect</td>
<td valign="top"><b><u>*YES</u></b>, *NO</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CRTLINX25.SWTDSCTMR"><b>SWTDSCTMR</b></a></td>
<td valign="top">Disconnect timers</td>
<td valign="top"><i>Element list</i></td>
<td valign="top" rowspan="3">Optional</td>
</tr>
<tr>
<td valign="top">Element 1: Minimum connect timer</td>
<td valign="top">
0-65535, <b><u>170</u></b></td>
</tr>
<tr>
<td valign="top">Element 2: Disconnection delay timer</td>
<td valign="top">
0-65535, <b><u>0</u></b></td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.DSRDRPTMR"><b>DSRDRPTMR</b></a></td>
<td valign="top">Data Set Ready drop timer</td>
<td valign="top">1-60, <b><u>6</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.AUTOANSTYP"><b>AUTOANSTYP</b></a></td>
<td valign="top">Autoanswer type</td>
<td valign="top"><b><u>*DTR</u></b>, *CDSTL</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.RMTANSTMR"><b>RMTANSTMR</b></a></td>
<td valign="top">Remote answer timer</td>
<td valign="top">30, 35, 40, 45, 50, 55, <b><u>60</u></b>, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CLOCK"><b>CLOCK</b></a></td>
<td valign="top">Clocking</td>
<td valign="top"><b><u>*MODEM</u></b>, *LOOP, *INVERT</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.SWTNWISLCT"><b>SWTNWISLCT</b></a></td>
<td valign="top">Switched NWI selection</td>
<td valign="top"><b><u>*FIRST</u></b>, *CALC</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.TEXT"><b>TEXT</b></a></td>
<td valign="top">Text 'description'</td>
<td valign="top"><i>Character value</i>, <b><u>*BLANK</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.X25DCE"><b>X25DCE</b></a></td>
<td valign="top">X.25 DCE support</td>
<td valign="top"><b><u>*NO</u></b>, *YES, *NEG</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.NETCTL"><b>NETCTL</b></a></td>
<td valign="top">Network controller</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.SWTCTLLST"><b>SWTCTLLST</b></a></td>
<td valign="top">Switched controller list</td>
<td valign="top">Single values: <b><u>*NONE</u></b>, *ALL<br>Other values (up to 64 repetitions): <i>Name</i></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.IDLTMR"><b>IDLTMR</b></a></td>
<td valign="top">Idle timer</td>
<td valign="top">3-600, <b><u>40</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.FRAMERTY"><b>FRAMERTY</b></a></td>
<td valign="top">Frame retry</td>
<td valign="top">0-64, <b><u>7</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.THRESHOLD"><b>THRESHOLD</b></a></td>
<td valign="top">Error threshold level</td>
<td valign="top"><b><u>*OFF</u></b>, *MIN, *MED, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.MODEM"><b>MODEM</b></a></td>
<td valign="top">Modem type supported</td>
<td valign="top"><b><u>*NORMAL</u></b>, *V54, *IBMWRAP</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.MODEMRATE"><b>MODEMRATE</b></a></td>
<td valign="top">Modem data rate select</td>
<td valign="top"><b><u>*FULL</u></b>, *HALF</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.CTSTMR"><b>CTSTMR</b></a></td>
<td valign="top">Clear To Send timer</td>
<td valign="top">10-60, <b><u>25</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.LINKSPEED"><b>LINKSPEED</b></a></td>
<td valign="top">Link speed</td>
<td valign="top"><b><u>*INTERFACE</u></b>, *MIN, 1200, 2400, 4800, 7200, 9600, 14400, 19200, 48000, 56000, 64000, 128000, 192000, 256000, 320000, 384000, 448000, 499000, 576000, 614000, 691000, 768000, 845000, 922000, 998000, 1075000, 1152000, 1229000, 1382000, 1536000, 1690000, 1843000, 1997000, 4M, 10M, 16M, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.COSTCNN"><b>COSTCNN</b></a></td>
<td valign="top">Cost/connect time</td>
<td valign="top">0-255, <b><u>128</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.COSTBYTE"><b>COSTBYTE</b></a></td>
<td valign="top">Cost/byte</td>
<td valign="top">0-255, <b><u>128</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.SECURITY"><b>SECURITY</b></a></td>
<td valign="top">Security for line</td>
<td valign="top">*NONSECURE, <b><u>*PKTSWTNET</u></b>, *UNDGRDCBL, *SECURECND, *GUARDCND, *ENCRYPTED, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.PRPDLY"><b>PRPDLY</b></a></td>
<td valign="top">Propagation delay</td>
<td valign="top">*MIN, *LAN, *TELEPHONE, <b><u>*PKTSWTNET</u></b>, *SATELLITE, *MAX</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.USRDFN1"><b>USRDFN1</b></a></td>
<td valign="top">User-defined 1</td>
<td valign="top">0-255, <b><u>128</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.USRDFN2"><b>USRDFN2</b></a></td>
<td valign="top">User-defined 2</td>
<td valign="top">0-255, <b><u>128</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CRTLINX25.USRDFN3"><b>USRDFN3</b></a></td>
<td valign="top">User-defined 3</td>
<td valign="top">0-255, <b><u>128</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CRTLINX25.CMNRCYLMT"><b>CMNRCYLMT</b></a></td>
<td valign="top">Recovery limits</td>
<td valign="top">Single values: *SYSVAL<br>Other values: <i>Element list</i></td>
<td valign="top" rowspan="3">Optional</td>
</tr>
<tr>
<td valign="top">Element 1: Count limit</td>
<td valign="top">
0-99, <b><u>2</u></b></td>
</tr>
<tr>
<td valign="top">Element 2: Time interval</td>
<td valign="top">
0-120, <b><u>5</u></b></td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CRTLINX25.MSGQ"><b>MSGQ</b></a></td>
<td valign="top">Message queue</td>
<td valign="top">Single values: <b><u>*SYSVAL</u></b>, *SYSOPR<br>Other values: <i>Qualified object name</i></td>
<td valign="top" rowspan="3">Optional</td>
</tr>
<tr>
<td valign="top">Qualifier 1: Message queue</td>
<td valign="top"><i>Name</i></td>
</tr><tr>
<td valign="top">Qualifier 2: Library</td>
<td valign="top"><i>Name</i></td>
</tr><tr>
<td valign="top"><a href="#CRTLINX25.AUT"><b>AUT</b></a></td>
<td valign="top">Authority</td>
<td valign="top"><i>Name</i>, <b><u>*CHANGE</u></b>, *ALL, *USE, *EXCLUDE, *LIBCRTAUT</td>
<td valign="top">Optional</td>
</tr>
</table>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
</div>
<div> <a name="CRTLINX25.LIND"></a>
<h3>Line description (LIND)</h3>
<p>Specifies the name of the line description
</p>
<p>This is a required parameter.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.RSRCNAME"></a>
<h3>Resource names (RSRCNAME)</h3>
<p>
<b>Note: </b>Use the Work with Hardware Resources (WRKHDWRSC) command with *CMN specified for the TYPE parameter to help determine the resource name. The resource name is on the port. For example, the resource name may be CMN01 on an Ethernet port.
</p>
<p>Specifies the resource name that identifies the hardware the description represents.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.LGLCHLE"></a>
<h3>Logical channel entries (LGLCHLE)</h3>
<p>Specifies, when using the Create Line X.25 Description (CRTLINX25) or Change Line Description X.25 (CHGLINX25) command, up to 256 entries to be added, removed, or changed in the logical channel table. A channel entry consists of a channel identifier, a logical channel type, and a PVC controller.
</p>
<p>You can enter multiple values for this parameter.
</p>
<p>The possible <b>channel identifier</b> values are:
</p>
<dl>
<dt><b>*PROMPT</b></dt>
<dd>Specifying *PROMPT presents an interactive display that can be used to process current logical channel entries.
</dd>
<dt><b><i>channel-identifier</i></b></dt>
<dd>Specify a three-character hexadecimal number ranging from 001 to FFF for the logical channel identifier. The first digit (from left to right) is the logical channel group number; the second and third digits make up the logical channel number. Specify a logical channel identifier. Valid values range from hexadecimal numeral 001 through FFF.
</dd>
</dl>
<p>The possible <b>channel type</b> values are:
</p>
<dl>
<dt><b>*PVC</b></dt>
<dd>The logical channel is a permanent virtual circuit.
</dd>
<dt><b>*SVCIN</b></dt>
<dd>The logical channel is a switched virtual circuit for incoming calls.
</dd>
<dt><b>*SVCBOTH</b></dt>
<dd>The logical channel is a switched virtual circuit for both incoming and outgoing calls.
</dd>
<dt><b>*SVCOUT</b></dt>
<dd>The logical channel is a switched virtual circuit for outgoing calls.
</dd>
</dl>
<dl>
<dt><b><i>PVC-controller</i></b></dt>
<dd>Specify the name of the PVC controller to be assigned to the logical channel. This field is valid only if *PVC is specified for the channel type.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.NETADR"></a>
<h3>Local network address (NETADR)</h3>
<p>Specifies the local network address for this system. Up to 17 characters can be specified if *YES is specified for the EXNNETADR parameter. Otherwise, up to 15 characters can be specified.
</p>
<dl>
<dt><b><i>local-network-address</i></b></dt>
<dd>Specify the local network address.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CNNINIT"></a>
<h3>Connection initiation (CNNINIT)</h3>
<p>Specifies the method used to establish the X.25 data link connection.
</p>
<dl>
<dt><b>*LOCAL</b></dt>
<dd>The local system initiates the connection by issuing the set asynchronous balanced mode (SABM) communications command to establish the connection.
</dd>
<dt><b>*REMOTE</b></dt>
<dd>The remote system initiates the connection issuing the SABM communications command. The local system waits for the connection to be established.
</dd>
<dt><b>*WAIT</b></dt>
<dd>The local system waits for a disconnect (DISC) or disconnect mode (DM) from the DCE before attempting to activate the link.
</dd>
<dt><b>*CALLER</b></dt>
<dd>The connection is initiated from either the local system or the remote system based on call direction.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.ONLINE"></a>
<h3>Online at IPL (ONLINE)</h3>
<p>Specifies whether this object is automatically varied on at initial program load (IPL).
</p>
<dl>
<dt><b>*YES</b></dt>
<dd>The line is automatically varied on at initial program load (IPL).
</dd>
<dt><b>*NO</b></dt>
<dd>This line is not automatically varied on at IPL.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.INTERFACE"></a>
<h3>Physical interface (INTERFACE)</h3>
<p>Specifies the type of physical interface on the input/output adapter (IOA) port.
</p>
<dl>
<dt><b>*X21BISV24 (X.25, BSC and SDLC only)</b></dt>
<dd>X.21 bis/V.24 physical interface.
</dd>
</dl>
<dl>
<dt><b>*X21BISV35 (X.25, BSC and SDLC only)</b></dt>
<dd>X.21 bis/V.35 physical interface.
</dd>
</dl>
<dl>
<dt><b>*X21 (X.25 and SDLC only)</b></dt>
<dd>X.21 physical interface.
</dd>
</dl>
<dl>
<dt><b>*RS232V24 (Async, BSC, X.25 and SDLC only)</b></dt>
<dd>RS-232/V.24 physical interface.
</dd>
</dl>
<dl>
<dt><b>*RS449V36 (Async, BSC, X.25 and SDLC only)</b></dt>
<dd>RS-449/V.36 physical interface.
</dd>
</dl>
<dl>
<dt><b>*INTMODEM</b></dt>
<dd>The integrated modem interface is used.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CNN"></a>
<h3>Connection type (CNN)</h3>
<p>Specifies the type of line connection.
</p>
<p>
<b>Note: </b>*NONSWTCAL and *NONSWTANS valid only when INTERFACE(*INTMODEM), or INFTRFTYPE *SYNCMODEM.
</p>
<dl>
<dt><b>*NONSWTPP</b></dt>
<dd>A nonswitched point-to-point line is used.
</dd>
</dl>
<dl>
<dt><b>*SWTPP</b></dt>
<dd>A switched point-to-point line is used.
</dd>
</dl>
<dl>
<dt><b>*NONSWTCAL</b></dt>
<dd>A nonswitched point-to-point line is used for call mode.
</dd>
</dl>
<dl>
<dt><b>*NONSWTANS</b></dt>
<dd>A nonswitched point-to-point line is used for answer mode.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.NWI"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Attached nonswitched NWI (NWI)</h3>
<p>Specifies, for a nonswitched connection, the network interface description containing the channel to which this line permanently attaches.
</p>
<p>
<b>Note: </b>Valid only when RSRCNAME(*NWID) and CNN not *SWTPP.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.NWICHLTYPE"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>NWI channel type (NWICHLTYPE)</h3>
<p>Specifies, for a nonswitched connection, the type of Integrated Services Digital Network (ISDN) channel that this line description uses. This parameter is pre-set to use one ISDN B-channel (a data-bearing channel) of the Network Interface description specified on the <b>Attached nonswitched NWI (NWI)</b> parameter.
</p>
<dl>
<dt><b>*B</b></dt>
<dd>The B channel is used.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.NWICHLNBR"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>NWI channel number (NWICHLNBR)</h3>
<p>Specifies, for a nonswitched connection, the channel number (1 through 30) of the network interface description that is used by this line description. 2, 23 or 30 channels are available for each network interface description, depending on whether the network interface is basic or primary rate and what the network type is, but only one line description can be permanently attached to a channel. The Display Network Interface Description (DSPNWID) command is used to display information about the channel numbers for a given NWID.
</p>
<p>
<b>Note: </b>Valid only when RSRCNAME(*NWID) and CNN not *SWTPP.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.SWTNWILST"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Switched NWI list (SWTNWILST)</h3>
<p>Specifies, for ISDN/T1 switched connections, a list of network interface descriptions to which this line can be attached. A network interface description is chosen from the list based on the value specified by the switched NWI selection parameter (SWTNWISLCT) at the time an incoming or outgoing call is processed.
</p>
<p>
<b>Note: </b>Valid only when RSRCNAME(*NWID) and CNN(*SWTPP).
</p>
<p>The possible <b>Network Interface Description Name</b> values are:
</p>
<dl>
<dt><b>*NONE</b></dt>
<dd>No network interface description is specified.
</dd>
<dt><b><i>name</i></b></dt>
<dd>Specify, for switched connections, the name of the network interface description to which this line attaches.
</dd>
</dl>
<p>The possible <b>Network Interface Channel Type</b> values are:
</p>
<dl>
<dt><b>*B</b></dt>
<dd>The B channel is used.
</dd>
</dl>
<p>The possible <b>Network Interface Channel-Number</b> values are:
</p>
<dl>
<dt><b>*CALC</b></dt>
<dd>The system selects one of the 30 channel numbers (based on availability) defined for the network interface description when an incoming or outgoing call is processed.
</dd>
<dt><b><i>NWI-channel-number</i></b></dt>
<dd>Specify a channel number (1 to 30) to which the line description is restricted.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.VRYWAIT"></a>
<h3>Vary on wait (VRYWAIT)</h3>
<p>Specifies whether the line is varied on asynchronously or synchronously. For synchronous vary on, this parameter specifies how long the system waits for the vary on to complete.
</p>
<dl>
<dt><b>*NOWAIT</b></dt>
<dd>The system does not wait for vary on completion. The line is varied on asynchronously.
</dd>
<dt><b><i>vary-on-wait</i></b></dt>
<dd>Specify the time (in seconds) to wait. Valid values range from 15 through 180. The system waits until the line is varied on, or until the specified time passes, before completing the Vary Configuration (VRYCFG) command.
</dd>
</dl>
<p><b>Notes:</b>
</p>
<ol>
<li>When ONLINE(*YES) is used, specifying a wait time in the line description affects system IPL time. In such cases, system IPL time is influenced by the amount of time required to synchronously vary on the line or reach the wait-time value.
</li>
<li>The time required to vary on a line is the time it takes to:
<ul>
<li>Put tasks in place to manage the line
</li>
<li>Activate the communications I/O processor (IOP), including downloading the IOP model-unique Licensed Internal Code
</li>
<li>Establish the communications tasks and processes
</li>
</ul>
</li>
</ol>
<p>Normal vary-on time ranges from 5 through 45 seconds, but can be longer, depending on the system, line protocol, and other factors.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.LINESPEED"></a>
<h3>Line speed (LINESPEED)</h3>
<p>Specifies the line speed in bits per second (bps).
</p>
<dl>
<dt><b>9600</b></dt>
<dd>The line speed is 9600 bps.
</dd>
</dl>
<dl>
<dt><b>*CALC</b></dt>
<dd>The system calculates the value to use.
</dd>
</dl>
<dl>
<dt><b><i>line-speed</i></b></dt>
<dd>Specify one of the following values (in bps) for the line speed:
<p>
<pre>
600 57600 576000 1152000 1728000
1200 64000 640000 1216000 1792000
2400 128000 704000 1280000 1856000
4800 192000 768000 1344000 1920000
7200 256000 832000 1408000 1984000
14400 320000 896000 1472000 2048000
19200 384000 960000 1536000
48000 448000 1024000 1600000
56000 512000 1088000 1664000
</pre>
</p>
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.EXCHID"></a>
<h3>Exchange identifier (EXCHID)</h3>
<p>Specifies the hexadecimal exchange identifier that is used to identify the local system to the remote system. The 8-digit hexadecimal exchange identifier contains three digits for the block number and five digits for the identifier of this system.
</p>
<dl>
<dt><b>*SYSGEN</b></dt>
<dd>This value allows the operating system to create the exchange identifier. Use the Display Line Description (DSPLIND) command to see the resulting exchange identifier.
</dd>
<dt><b><i>exchange-ID</i></b></dt>
<dd>Specify an 8-character (four hexadecimal bytes) exchange identifier ranging from 05600000 through 056FFFFF.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.PKTMODE"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Packet mode (PKTMODE)</h3>
<p>Specifies whether to access the ISDN or T1 virtual circuit service.
</p>
<dl>
<dt><b>*NO</b></dt>
<dd>The ISDN/T1 network is used to provide transparent access to an X.25 packet switched network external to the ISDN/T1 (Case A).
</dd>
<dt><b>*YES</b></dt>
<dd>The ISDN/T1 virtual circuit service is accessed (Case B).
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.INFTRFTYPE"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Information transfer type (INFTRFTYPE)</h3>
<p>Specifies the information transfer type. The information transfer type determines the layer 1 protocol.
</p>
<p>
<b>Note: </b>Valid only when RSRCNAME(*NWID) and CNN not *SWTPP.
</p>
<dl>
<dt><b>*UNRESTRICTED</b></dt>
<dd>The data-channel traffic appears as digital information; no physical transformation is required and each B-channel operates at capacity (64k bps).
</dd>
<dt><b>*V110</b></dt>
<dd>The transfer type is V-series Recommendation 110. Each B-channel operates at 56k bps.
</dd>
<dt><b>*DOV</b></dt>
<dd>Allows Data Over Voice (DOV) digital data to be transferred over an ISDN/T1 voice call. Also, this is referred to as Data Over Voice Bearer Service (DOVBS), Data Over Speech Bearer Service (DOSBS), TollSaver, or TollMizer. This option should only be used if an ISDN voice call is less expensive than an ISDN data call or if a bearer service for data is not available. The remote location must also support this feature. Data is transferred at 56Kbps in each direction.
</dd>
<dt><b>*SYNCMODEM</b></dt>
<dd>Allows data from the integrated synchronous modem to be transferred over an ISDN/T1 voice call. This option should be used to connect to a remote location that is using a synchronous modem on an analog telephone line. Data is transferred at modem speeds up to 33.6Kbps from the remote analog device to this digital connection and up to 56Kbps from this digital connection to the remote analog device.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.EXNNETADR"></a>
<h3>Extended network addressing (EXNNETADR)</h3>
<p>Specifies whether network addressing is extended to permit the use of 17 characters in an address name.
</p>
<dl>
<dt><b>*NO</b></dt>
<dd>Network addresses can be up to 15 characters.
</dd>
<dt><b>*YES</b></dt>
<dd>Network addresses can be up to 17 characters.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.MAXFRAME"></a>
<h3>Maximum frame size (MAXFRAME)</h3>
<p>Specifies the maximum frame size that can be transmitted and received on this line description.
</p>
<dl>
<dt><b>1024</b></dt>
<dd>The default frame size is 1024.
</dd>
<dt><b><i>maximum-frame-size</i></b></dt>
<dd>Specify one of the following values: 1024, 2048, or 4096.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.DFTPKTSIZE"></a>
<h3>Default packet size (DFTPKTSIZE)</h3>
<p>Specifies the default packet sizes used for transmission and reception on this line. The values specified should match the default values used by the X.25 network.
</p>
<p>The possible <b>transmission</b> values are:
</p>
<dl>
<dt><b>128</b></dt>
<dd>The default packet size is 128.
</dd>
<dt><b><i>transmit-packet-size</i></b></dt>
<dd>Specify a default packet size for transmission to all controllers that will attach to this line. The controller commands can override this default with the DFTPKTSIZE parameter on the controller commands. The valid values for the packet size are 64, 128, 256, 512, 1024, 2048, and 4096.
</dd>
</dl>
<p>The possible <b>reception</b> values are:
</p>
<dl>
<dt><b>*TRANSMIT</b></dt>
<dd>The value specified as the default packet size for transmission is used as the default for reception.
</dd>
<dt><b><i>receive-packet-size</i></b></dt>
<dd>Specify a default packet size for reception for all controllers that will attach to this line. The controller commands can override this default with the DFTPKTSIZE parameter on the controller commands. The valid values for the packet size are 64, 128, 256, 512, 1024, 2048, and 4096.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.MAXPKTSIZE"></a>
<h3>Maximum packet size (MAXPKTSIZE)</h3>
<p>Specifies the maximum packet sizes for transmission and reception on this line. These values should match the maximum packet sizes supported for transmission and reception by the X.25 network. The value specified must not be less than the default packet size specified.
</p>
<p>The possible <b>transmission</b> values are:
</p>
<dl>
<dt><b>*DFTPKTSIZE</b></dt>
<dd>The maximum packet size for transmission is the same as the default packet size for transmission.
</dd>
</dl>
<dl>
<dt><b><i>max-transmit-packet-size</i></b></dt>
<dd>Specify a packet size for transmission to all controllers attached to this line. The valid values for the packet size are 64, 128, 256, 512, 1024, 2048, and 4096.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.MODULUS"></a>
<h3>Modulus (MODULUS)</h3>
<p>Specifies whether the extended sequence numbers are used.
</p>
<dl>
<dt><b>8</b></dt>
<dd>Extended sequence numbers are not used (Modulus 8).
</dd>
<dt><b><i>128</i></b></dt>
<dd>Extended sequence numbers are used (Modulus 128).
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.DFTWDWSIZE"></a>
<h3>Default window size (DFTWDWSIZE)</h3>
<p>Specifies the default packet window size for transmission to and reception from controllers attached to this line. The controllers can override this default by specifying the <b>X.25 default window size (DFTWDWSIZE)</b> parameter on the controller commands.
</p>
<p>The possible <b>transmission</b> values are:
</p>
<dl>
<dt><b>2</b></dt>
<dd>The default packet window size is 2.
</dd>
<dt><b><i>transmit-window-size</i></b></dt>
<dd>Specify the appropriate default window size. If you specified modulus 8, valid values range from 1 through 7. If you specified modulus 128, valid values range from 1 through 15.
</dd>
</dl>
<p>The possible <b>reception</b> values are:
</p>
<dl>
<dt><b>*TRANSMIT</b></dt>
<dd>The value specified as the default window size for transmission is used as the default for reception.
</dd>
<dt><b><i>receive-window-size</i></b></dt>
<dd>Specify the appropriate default window size. If you specified modulus 8, valid values range from 1 through 7. If you specified modulus 128, valid values range from 1 through 15.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.ADRINSERT"></a>
<h3>Insert net address in packets (ADRINSERT)</h3>
<p>Specifies whether the system inserts the local network address in call request packets.
</p>
<dl>
<dt><b>*YES</b></dt>
<dd>The local network address is inserted in packets.
</dd>
<dt><b>*NO</b></dt>
<dd>The local network address is not inserted in packets.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.NETUSRID"></a>
<h3>Network user ID (NETUSRID)</h3>
<p>For switched lines, this parameter allows the network subscriber to request network user identification (NUI) information be encoded in the NUI Selection Facility for all call request packets sent by the local system on this line.
</p>
<dl>
<dt><b><i>network-user-identification</i></b></dt>
<dd>Specify a NUI up to 214 hexadecimal characters in length.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CNNNBR"></a>
<h3>Connection number (CNNNBR)</h3>
<p>Specifies the number used to connect to this line. This is the telephone number to be dialed by the modem. A maximum of 32 characters can be specified.
</p>
<dl>
<dt><b><i>connection-number</i></b></dt>
<dd>Specifies the connection number.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CALLNBR"></a>
<h3>Calling number (CALLNBR)</h3>
<p>Specifies the local telephone number of the line that is used for the V.25 bis Call Request with Identification (CRI) dial command. When V.25 bis CRI dialing is used, the system takes the called (connection) number (CNNNBR parameter ), adds a separator character (;), and puts the calling number at the end. The default, *NONE, indicates that Call Request Normal (CRN) is used.
</p>
<p>Specify the calling number only when the modem and network support the CRI dial command.
</p>
<dl>
<dt><b>*NONE</b></dt>
<dd>Call Request Normal (CRN) is used. CRN dialing sends only the connection number to the V.25 bis modem.
</dd>
</dl>
<dl>
<dt><b><i>calling-number</i></b></dt>
<dd>Specify the local telephone number if V.25 bis CRI dialing is required. The number can be up to 32 characters in length. See your modem documentation to determine the values allowed by the modem.
</dd>
</dl>
<p>
<b>Note: </b>Specify the calling number only if both the modem and network support the V.25 bis CRI dial command.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.SWTCNN"></a>
<h3>Switched connection type (SWTCNN)</h3>
<p>Specifies whether the switched (Async, BSC, SDLC, or IDLC) line or switched network backup (Async, BSC, or SDLC) line is used for incoming calls, outgoing calls, or both.
</p>
<dl>
<dt><b>*BOTH</b></dt>
<dd>The line is used for both incoming and outgoing calls.
</dd>
</dl>
<dl>
<dt><b>*ANS</b></dt>
<dd>The line is used for incoming calls only.
</dd>
</dl>
<dl>
</dl>
<dl>
<dt><b>*DIAL</b></dt>
<dd>The line is used for outgoing calls only.
</dd>
</dl>
<dl>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CNNLSTOUT"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Outgoing connection list (CNNLSTOUT)</h3>
<p>Specifies, for ISDN switched connections, the name of a connection list object that contains the ISDN assigned numbers for a dial-out operation to the ISDN.
</p>
<dl>
<dt><b>*NONE</b></dt>
<dd>A user specified connection list for dial-out operations is not used. The connection list is automatically configured if OSI Communications Subsystems is installed.
</dd>
<dt><b><i>name</i></b></dt>
<dd>Specify the name of the connection list for dial out operations.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CNNLSTOUTE"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Connection list entry (CNNLSTOUTE)</h3>
<p>Specifies, for ISDN switched connections, the entry name from the connection list used to make a call to the ISDN. The connection list must be specified on the CNNLSTOUT parameter.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CNNLSTIN"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Incoming connection list (CNNLSTIN)</h3>
<p>Specifies for ISDN switched connections the name of the connection list that is used to retrieve call information (or connection) for identifying authorized incoming calls.
</p>
<dl>
<dt><b>*NETATR</b></dt>
<dd>The connection list used by this line description is taken from the list of system default network attributes that were identified at IPL (Initial Program Load). The Display Network Attributes (DSPNETA) command can be used to see the name of the connection list.
</dd>
<dt><b><i>name</i></b></dt>
<dd>Specify the name of the connection list used for this line description.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.AUTOANS"></a>
<h3>Autoanswer (AUTOANS)</h3>
<p>Specifies, for switched or switched network backup lines (Async, BSC, SDLC, or X.25 line), whether the system automatically answers a call from a remote system to establish the connection, or whether the system operator manually answers the call and places the modem in data mode.
</p>
<p>
<b>Note: </b>*YES is a valid option only if the modem has the automatic answer feature.
</p>
<dl>
<dt><b>*YES</b></dt>
<dd>The incoming call is automatically answered by the automatic answer feature.
</dd>
<dt><b>*NO</b></dt>
<dd>The incoming call must be manually answered.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.AUTODIAL"></a>
<h3>Autodial (AUTODIAL)</h3>
<p>Specifies, for switched lines, whether the system automatically calls a remote system to establish a connection or if the system operator must manually place the call.
</p>
<dl>
<dt><b>*NO</b></dt>
<dd>The line connection is made by manually dialing the X.25 network.
</dd>
<dt><b>*YES</b></dt>
<dd>The line connection is made by the system automatically dialing the X.25 network.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.DIALCMD"></a>
<h3>Dial command type (DIALCMD)</h3>
<p>Specifies the type of dial command used to establish a switched connection with a remote system.
</p>
<dl>
<dt><b>*NONE</b></dt>
<dd>No dial command is used. (An automatic call unit is used to establish the connection.)
</dd>
</dl>
<dl>
<dt><b>*V25BIS</b></dt>
<dd>V.25 bis is a recommendation which allows the use of one physical interface for call establishment and data transmission. It is referred to as a serial automatic call interface because the digits are presented serially on the link from the system to the modem.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.MDMINZCMD"></a>
<h3>Modem init command string (MDMINZCMD)</h3>
<p>Specifies the modem initialization command string sent to set the modem.
</p>
<p>
<b>Note: </b>Valid only when INTERFACE(*INTMODEM) or INFTRFTYPE(*SYNCMODEM) is specified.
</p>
<dl>
<dt><b>*NONE</b></dt>
<dd>No command string is sent to the modem.
</dd>
</dl>
<dl>
<dt><b><i>command-string</i></b></dt>
<dd>Specifies up to 60 characters that represent the command string sent to the modem. Valid characters are upper case A thru Z, lower case a thru z, numbers 0 thru 9, and special characters:
</dd>
</dl>
<p>
<pre>
Period
Less than sign
Left parenthesis
Plus sign
Ampersand
Asterisk
Right parenthesis
Semicolon
Minus sign
Slash
Comma
Underline
Greater than sign
Question mark
Colon
Equal sign
Spaces
Number sign
Double quote
Exclamation point
At sign
Hat symbol
Percent
Left square bracket
Right square bracket
Back slash
</pre>
</p>
<p>
<b>Note: </b>The modem initialization string must begin with the two characters 'AT'.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CALLIMMED"></a>
<h3>Call immediate (CALLIMMED)</h3>
<p>Specifies, for switched lines, whether a call (using the number specified in the CNNNBR parameter) is made immediately after varying on the line.
</p>
<dl>
<dt><b>*NO</b></dt>
<dd>The system does not try to immediately call after varying on.
</dd>
<dt><b>*YES</b></dt>
<dd>The system does try to immediately call after varying on.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.AUTOCALL"></a>
<h3>Autocall unit (AUTOCALL)</h3>
<p>Specifies, for switched or switched network backup lines (Async, BSC, SDLC, or X.25 line), whether the line has an associated automatic call unit that can automatically call the remote system.
</p>
<dl>
<dt><b>*NO</b></dt>
<dd>No automatic call unit is associated with this line.
</dd>
<dt><b>*YES</b></dt>
<dd>An automatic call unit is associated with this line.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.ACRSRCNAME"></a>
<h3>Autocall resource name (ACRSRCNAME)</h3>
<p>Specifies the automatic call resource name that describes the automatic call unit port that is used to establish a connection with a remote system. Use the Work with Hardware Resources (WRKHDWRSC) command to determine the resource name.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.PREDIALDLY"></a>
<h3>Predial delay (PREDIALDLY)</h3>
<p>Specifies the time interval to wait before dialing a number.
</p>
<dl>
<dt><b>6</b></dt>
<dd>The default value of six provides a 3-second delay.
</dd>
<dt><b><i>predial-delay</i></b></dt>
<dd>Specify a value ranging from 0 through 254 units. Each unit represents 0.5 second. To indicate no delay, specify a value of 0.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.REDIALDLY"></a>
<h3>Redial delay (REDIALDLY)</h3>
<p>Specifies the time interval to wait (in 0.5 second intervals) before re-dialing when the call attempt is unsuccessful.
</p>
<dl>
<dt><b>120</b></dt>
<dd>The default value of 120 provides a 60-second delay.
</dd>
<dt><b><i>redial-delay</i></b></dt>
<dd>Specify a value ranging from 0 through 254 units. Each unit represents 0.5 second. To indicate no delay, specify a value of 0.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.DIALRTY"></a>
<h3>Dial retry (DIALRTY)</h3>
<p>Specifies the number of re-dial attempts made by the system before considering the dialing unsuccessful.
</p>
<dl>
<dt><b>2</b></dt>
<dd>The default number of retries is 2.
</dd>
<dt><b><i>dial-retry</i></b></dt>
<dd>Specify a value ranging from 0 through 254.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.SWTDSC"></a>
<h3>Switched disconnect (SWTDSC)</h3>
<p>Specifies whether the line is dropped when the last switched virtual circuit (SVC) is cleared and the switched disconnect timers (SWTDSCTMRs) have expired.
</p>
<dl>
<dt><b>*YES</b></dt>
<dd>The switched connection is dropped.
</dd>
<dt><b>*NO</b></dt>
<dd>The switched connection is not dropped.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.SWTDSCTMR"></a>
<h3>Disconnect timers (SWTDSCTMR)</h3>
<p>Specifies the timers used for disconnecting switched X.25 lines from the network or remote system. The minimum connect timer specifies the minimum length of time the system keeps the connection active. This timer is started when the connection is established. The disconnect delay timer specifies the length of time the system waits before attempting to disconnect the switched connection when no SVCs are active on the line or the last SVC completes and the <b>minimum-connect-timer</b> has expired.
</p>
<p>The possible <b>minimum-connect-timer</b> values are:
</p>
<dl>
<dt><b><i>min-connect-timer</i></b></dt>
<dd>Specify a value ranging from 0 through 65535 seconds.
</dd>
</dl>
<p>The possible <b>disconnect-delay-timer</b> values are:
</p>
<dl>
<dt><b><i>disconnect-delay-timer</i></b></dt>
<dd>Specify a value ranging from 0 through 65535 seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.DSRDRPTMR"></a>
<h3>Data Set Ready drop timer (DSRDRPTMR)</h3>
<p>Specifies the amount of time that the system waits for the modem to exit the Data Set Ready (DSR) state before signaling an error.
</p>
<dl>
<dt><b><i>drop-timer</i></b></dt>
<dd>Specify a value ranging from 1 through 60 seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.AUTOANSTYP"></a>
<h3>Autoanswer type (AUTOANSTYP)</h3>
<p>Specifies the method that the system uses to answer incoming calls.
</p>
<dl>
<dt><b>*DTR</b></dt>
<dd>The system enters the Data Terminal Ready state, signals the modem to answer calls, and waits for the modem to enter the Data Set Ready (DSR) state.
</dd>
<dt><b>*CDSTL</b></dt>
<dd>The system enters the Connect Data Set to Line (CDSTL) state after monitoring the Ring Indicator to signal the modem to answer the call.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.RMTANSTMR"></a>
<h3>Remote answer timer (RMTANSTMR)</h3>
<p>Specifies the amount of time that system waits for the modem to enter the Data Set Ready (DSR) state after dialing before signaling an error.
</p>
<dl>
<dt><b><i>answer-timer</i></b></dt>
<dd>Specify a value ranging from 30 through 120 seconds in 5-second intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CLOCK"></a>
<h3>Clocking (CLOCK)</h3>
<p>Specifies how the clocking function for the line is provided.
</p>
<dl>
<dt><b>*MODEM</b></dt>
<dd>The modem supplies the clocking function.
</dd>
<dt><b>*LOOP</b></dt>
<dd>The receiving clock provided by the modem data circuit-terminating equipment (DCE) is looped back to the modem DCE on the system data terminal equipment (DTE) transmitting clock. This option can be used to improve high speed data transmission when the modem DCE supports such an option.
</dd>
<dt><b>*INVERT</b></dt>
<dd>The transmit clock provided by the modem data circuit-terminating equipment (DCE) is inverted before use. This option can be used when having problems with high speed data transmission and the modem (DCE) does not support looped clocking. The valid interfaces for *INVERT are *X21, *X21BISV35, and *RS449V36.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.SWTNWISLCT"></a>
<p>
<b>Note: </b>This parameter is no longer supported. It exists solely for compatibility with releases earlier than Version 5 Release 3 Modification 0 of the operating system.
</p>
<h3>Switched NWI selection (SWTNWISLCT)</h3>
<p>Specifies the method used to select network interfaces from the switched network interface list.
</p>
<dl>
<dt><b>*FIRST</b></dt>
<dd>Selection begins with the first network interface specified in the switched network interface list.
</dd>
<dt><b>*CALC</b></dt>
<dd>The system calculates which network interface is selected.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.TEXT"></a>
<h3>Text 'description' (TEXT)</h3>
<p>Specifies text that briefly describes the line description.
</p>
<dl>
<dt><b>*BLANK</b></dt>
<dd>Text is not specified.
</dd>
<dt><b><i>character-value</i></b></dt>
<dd>Specify no more than 50 characters of text, enclosed in apostrophes.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.X25DCE"></a>
<h3>X.25 DCE support (X25DCE)</h3>
<p>Specifies whether the system communicates through the X.25 data circuit-terminating equipment (DCE) support. This allows a system to communicate with another system without going through an X.25 network.
</p>
<dl>
<dt><b>*NO</b></dt>
<dd>The system does not communicate through the X.25 DCE support.
</dd>
<dt><b>*YES</b></dt>
<dd>The system does communicate through the X.25 DCE support.
</dd>
</dl>
<dl>
<dt><b>*NEG</b></dt>
<dd>The operating system negotiates with another system about whether to communicate through the X.25 DCE support. This value can only be specified for switched lines.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.NETCTL"></a>
<h3>Network controller (NETCTL)</h3>
<p>Specifies the name of an existing network controller.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.SWTCTLLST"></a>
<h3>Switched controller list (SWTCTLLST)</h3>
<p>Specifies the names of up to 64 switched asynchronous controllers or specify *ALL for an unlimited number of switched asynchronous X.25 controllers that can establish a connection with an X.25 switched virtual circuit (SVC). The controller descriptions must already exist. This parameter is valid only if the line is used to attach switched asynchronous X.25 controllers created by the Create Controller Description (Async) (CRTCTLASC) command. Attaching controllers that specify CNNNBR(*ANY) or ANSNBR(*ANY) may result in a reordering of this list.
</p>
<p>You can enter multiple values for this parameter.
</p>
<dl>
<dt><b>*ALL</b></dt>
<dd>All X.25 switched controllers that are created using the Create Controller Description (Async) (CRTCTLASC) command and list this line description on the Switched Line List (SWTLINLST) parameter can be used to establish a connection with an X.25 switched virtual circuit (SVC).
</dd>
<dt><b>*NONE</b></dt>
<dd>No switched asynchronous controller is specified.
</dd>
<dt><b><i>names</i></b></dt>
<dd>Specify the switched controller names. Up to 64 switched controllers can be specified.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.IDLTMR"></a>
<h3>Idle timer (IDLTMR)</h3>
<p>Specifies the maximum amount of time (in 0.1 second intervals) that the system waits for acknowledgment from the network for each frame sent before re-transmission.
</p>
<p>
<b>Note: </b>The IDLTMR value should be greater than or equal to the following equation: (2 * P + (MAXPKTSIZE * 8) / LINESPEED + D) * 10, where "P" is the propagation delay (in seconds) of the medium that connects you to the network, MAXPKTSIZE is the maximum transmit packet size, and "D" is the DCE (Data Circuit-terminating Equipment) processing overhead (in seconds). Contact your network provider for information regarding these two values.
</p>
<dl>
<dt><b>40</b></dt>
<dd>The default for this parameter is 40.
</dd>
</dl>
<dl>
<dt><b><i>idle-timer</i></b></dt>
<dd>Specify a value ranging from 3 through 600. Each unit represents 0.1 seconds, which provides a timeout value ranging from 0.3 through 60 seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.FRAMERTY"></a>
<h3>Frame retry (FRAMERTY)</h3>
<p>Specifies, for a primary, negotiable, or X.25 line, the number of retries for an unanswered command frame or unacknowledged information frame before indicating the error.
</p>
<dl>
<dt><b><i>frame-retry</i></b></dt>
<dd>Specify a value from 0 to 64 for the number of retries.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.THRESHOLD"></a>
<h3>Error threshold level (THRESHOLD)</h3>
<p>Specifies the temporary error threshold level being monitored by the system. A permanent error is reported only if the errors occurred consecutively and exceeded the retry limit.
</p>
<p>
<b>Note: </b>Specifying the THRESHOLD parameter affects all threshold errors. They cannot be specified individually.
</p>
<dl>
<dt><b>*OFF</b></dt>
<dd>No threshold errors are reported.
</dd>
</dl>
<dl>
<dt><b>*MIN</b></dt>
<dd>The threshold for errors is set to a minimum monitoring level.
</dd>
</dl>
<dl>
<dt><b>*MED</b></dt>
<dd>The threshold for errors is set to a medium monitoring level.
</dd>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>The threshold for errors is set to a maximum monitoring level.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.MODEM"></a>
<h3>Modem type supported (MODEM)</h3>
<p>Specifies the type of modem supported on the communications line. Refer to the modem manual to determine the appropriate value to select.
</p>
<dl>
<dt><b>*NORMAL</b></dt>
<dd>No attempt is made to run diagnostic tests to your modem.
</dd>
<dt><b>*V54</b></dt>
<dd>Certain types of diagnostic tests (as defined by the CCITT recommendations) are run to your modem. This system supports CCITT V.54 loop 3, (a local loop back,) and loop 2, (which is a remote loop back).
</dd>
<dt><b>*IBMWRAP</b></dt>
<dd>An IBM modem with wrap test capabilities is used on the communications line.
</dd>
<dt><b>*IBMLPDA1</b></dt>
<dd>An IBM modem with Link Problem Determination Aid-1 (LPDA-1) is used on the line.
</dd>
</dl>
<dl>
<dt><b>*IBMLPDA2</b></dt>
<dd>An IBM modem with Link Problem Determination Aid-2 (LPDA-2) is used on the line.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.MODEMRATE"></a>
<h3>Modem data rate select (MODEMRATE)</h3>
<p>Specifies the speed at which the line operates if the modem has the data rate select feature.
</p>
<dl>
<dt><b>*FULL</b></dt>
<dd>The line operates at the full rate of the modem.
</dd>
<dt><b>*HALF</b></dt>
<dd>The line operates at half the full rate of the modem.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CTSTMR"></a>
<h3>Clear To Send timer (CTSTMR)</h3>
<p>Specifies the amount of time the system waits for the modem to enter or exit the Clear to Send (CTS) state before signaling an error.
</p>
<dl>
<dt><b><i>cts-timer</i></b></dt>
<dd>Specify a value ranging from 10 through 60 seconds.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.LINKSPEED"></a>
<h3>Link speed (LINKSPEED)</h3>
<p>Specifies the link speed in bits per second (bps). This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b>*INTERFACE (SDLC and X.25 only)</b></dt>
<dd>The link speed is based on the physical interface type: 9600 bps for RS-232/V.24 and X.21 bis/V.24, 48000 bps for V.35 and X.21 bis/V.35, and 64000 bps for X.21.
</dd>
</dl>
<dl>
<dt><b>*MIN</b></dt>
<dd>A link speed of less than 1200 bps is used.
</dd>
</dl>
<dl>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>A link speed greater than 100M bps is used.
</dd>
</dl>
<dl>
<dt><b><i>link-speed</i></b></dt>
<dd>Specify the link speed. Valid values are: 1200, 2400, 4800, 7200, 9600, 14400, 19200, 48000, 56000, 64000, 128000, 192000, 256000, 320000, 384000, 448000, 499000, 576000, 614000, 691000, 768000, 845000, 922000, 998000, 1075000, 1152000, 1229000, 1382000, 1536000, 1690000, 1843000, 1997000, 4M, 10M, and 16M.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.COSTCNN"></a>
<h3>Cost/connect time (COSTCNN)</h3>
<p>Specifies the relative cost of being connected on the line. Zero implies a low cost while 255 indicates a high cost. This parameter is valid only if APPN is used on the system.
</p>
<dl>
<dt><b>*CNN (SDLC and IDLC only)</b></dt>
<dd>The cost per connection time is based on the connection type: Zero for nonswitched connections and 128 for switched connections.
</dd>
<dt><b><i>cost-per-connect-time</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.COSTBYTE"></a>
<h3>Cost/byte (COSTBYTE)</h3>
<p>Specifies the relative cost per byte for sending and receiving data on the line. Zero implies a low cost while 255 indicates a high cost. This parameter is valid only if APPN is used on the system.
</p>
<dl>
<dt><b>*CNN (SDLC and IDLC only)</b></dt>
<dd>The cost per byte is based on the connection type: Zero for nonswitched connections and 128 for switched connections.
</dd>
<dt><b><i>cost-per-byte</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.SECURITY"></a>
<h3>Security for line (SECURITY)</h3>
<p>Specifies the security level of the physical line. This parameter is valid only if APPN is used on the system.
</p>
<dl>
<dt><b>*NONSECURE</b></dt>
<dd>There is no security on the line.
</dd>
<dt><b>*PKTSWTNET</b></dt>
<dd>A packet switched network is used. Data does not always follow the same path through the network.
</dd>
<dt><b>*UNDRGRDCBL</b></dt>
<dd>An underground cable is used.
</dd>
<dt><b>*SECURECND</b></dt>
<dd>A secure, but unguarded, conduit is used.
</dd>
<dt><b>*GUARDCND</b></dt>
<dd>A guarded conduit, protected against physical tapping, is used.
</dd>
<dt><b>*ENCRYPTED</b></dt>
<dd>Data flowing on the line is encrypted.
</dd>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>A guarded conduit, protected against physical and radiation tapping is used.
</dd>
</dl>
<dl>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.PRPDLY"></a>
<h3>Propagation delay (PRPDLY)</h3>
<p>Specifies the level of propagation delay on the line. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system. The order of the values from shortest to longest delay is *MIN, *LAN, *TELEPHONE, *PKTSWTNET, and *SATELLITE.
</p>
<dl>
<dt><b>*MIN</b></dt>
<dd>The minimum propagation delay is used.
</dd>
</dl>
<dl>
<dt><b>*LAN</b></dt>
<dd>Propagation delay using a local area network.
</dd>
<dt><b>*TELEPHONE</b></dt>
<dd>Propagation delay using telephone lines.
</dd>
<dt><b>*PKTSWTNET</b></dt>
<dd>Propagation delay using a packet switched network.
</dd>
<dt><b>*SATELLITE</b></dt>
<dd>Propagation delay using satellite communications.
</dd>
</dl>
<dl>
<dt><b>*MAX</b></dt>
<dd>The maximum propagation delay is used.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.USRDFN1"></a>
<h3>User-defined 1 (USRDFN1)</h3>
<p>This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b>128</b></dt>
<dd>The default value is 128.
</dd>
</dl>
<dl>
<dt><b><i>user-defined-1</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.USRDFN2"></a>
<h3>User-defined 2 (USRDFN2)</h3>
<p>This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b>128</b></dt>
<dd>The default value is 128.
</dd>
</dl>
<dl>
<dt><b><i>user-defined-2</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.USRDFN3"></a>
<h3>User-defined 3 (USRDFN3)</h3>
<p>This field is used to describe unique characteristics of the line that you want to control. This parameter is valid only if advanced peer-to-peer networking (APPN) is used on the system.
</p>
<dl>
<dt><b>128</b></dt>
<dd>The default value is 128.
</dd>
</dl>
<dl>
<dt><b><i>user-defined-3</i></b></dt>
<dd>Specify a value ranging from 0 through 255.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.CMNRCYLMT"></a>
<h3>Recovery limits (CMNRCYLMT)</h3>
<p>Specifies the second-level communications recovery limits to be used for this line description.
</p>
<p>The possible <b>count-limit</b> values are:
</p>
<dl>
<dt><b>2</b></dt>
<dd>Two recovery attempts are made within the specified time interval.
</dd>
</dl>
<dl>
<dt><b>*SYSVAL</b></dt>
<dd>The value in the QCMNRCYLMT system value is used.
</dd>
</dl>
<dl>
<dt><b><i>count-limit</i></b></dt>
<dd>Specify the number of recovery attempts to be performed by the system. Valid values range from 0 through 99.
</dd>
</dl>
<p>The possible <b>time-interval</b> values are:
</p>
<dl>
<dt><b>5</b></dt>
<dd>The specified number of recovery attempts are made within a 5-minute interval.
</dd>
</dl>
<dl>
<dt><b><i>time-interval</i></b></dt>
<dd>Specify the number of minutes within which recovery attempts are made. Valid values range from 0 through 120 in 1-minute intervals.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.MSGQ"></a>
<h3>Message queue (MSGQ)</h3>
<p>Specifies the message queue to which operational messages are sent.
</p>
<dl>
<dt><b><u>*SYSVAL</u></b></dt>
<dd>The value in the system value QCFGMSGQ is used.
</dd>
</dl>
<dl>
<dt><b>*SYSOPR</b></dt>
<dd>Messages are sent to the system operator message queue (QSYS/QSYSOPR).
</dd>
</dl>
<p><b>Qualifier 1: Message queue</b>
</p>
<dl>
<dt><b><i>name</i></b></dt>
<dd>Specify the name of the message queue to which operational messages are sent.
</dd>
</dl>
<p><b>Qualifier 2: Library</b>
</p>
<dl>
<dt><b><i>name</i></b></dt>
<dd>Specify the name of the library where the message queue is located.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CRTLINX25.AUT"></a>
<h3>Authority (AUT)</h3>
<p>Specifies the authority you are giving to users who do not have specific authority for the object, who are not on an authorization list, and whose group profile or supplemental group profiles do not have specific authority for the object.
</p>
<dl>
<dt><b><u>*CHANGE</u></b></dt>
<dd>The user can perform all operations on the object except those limited to the owner or controlled by object existence (*OBJEXIST) and object management (*OBJMGT) authorities. The user can change and perform basic functions on the object. *CHANGE authority provides object operational (*OBJOPR) authority and all data authority. If the object is an authorization list, the user cannot add, change, or remove users.
</dd>
</dl>
<dl>
<dt><b>*ALL</b></dt>
<dd>The user can perform all operations except those limited to the owner or controlled by authorization list management (*AUTLMGT) authority. The user can control the object's existence, specify the security for the object, change the object, and perform basic functions on the object. The user also can change ownership of the object.
</dd>
</dl>
<dl>
<dt><b>*USE</b></dt>
<dd>The user can perform basic operations on the object, such as running a program or reading a file. The user cannot change the object. Use (*USE) authority provides object operational (*OBJOPR), read (*READ), and execute (*EXECUTE) authorities.
</dd>
</dl>
<dl>
<dt><b>*EXCLUDE</b></dt>
<dd>The user cannot access the object.
</dd>
</dl>
<dl>
<dt><b>*LIBCRTAUT</b></dt>
<dd>The system determines the authority for the object by using the value specified for the <b>Create authority (CRTAUT)</b> parameter on the Create Library (CRTLIB) command for the library containing the object to be created. If the value specified for the CRTAUT parameter is changed, the new value will not affect any existing objects.
</dd>
</dl>
<dl>
<dt><b><i>name</i></b></dt>
<dd>Specify the name of an authorization list to be used for authority to the object. Users included in the authorization list are granted authority to the object as specified in the list. The authorization list must exist when the object is created.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div><h3><a name="CRTLINX25.COMMAND.EXAMPLES">Examples</a> </h3>
<p>
<pre>
CRTLINX25 LIND(X251) RSRCNAME(LIN011)
LGLCHLE((111 *PVC CTL1) (222 *SVCIN))
NETADR(12345) CNNINIT(*LOCAL) TEXT('X.25 Line')
</pre>
</p>
<p>This command creates an X.25 line (X251) with resource name LIN011, two logical channels (with an attached PVC controller), a network address of 12345, and local connection initiation.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div><h3><a name="CRTLINX25.ERROR.MESSAGES">Error messages</a> </h3>
<p><b><u>*ESCAPE Messages</u></b>
</p>
<dl>
<dt><b>CPF2718</b></dt>
<dd>Line description &amp;1 not created due to errors.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CRTLINX25.Top_Of_Page">Top</a></td></tr>
</table>
</body>
</html>