ibm-information-center/dist/eclipse/plugins/i5OS.ic.cl_5.4.0.1/chgewcbcde.htm

654 lines
20 KiB
HTML
Raw Permalink Normal View History

2024-04-02 14:02:31 +00:00
<!doctype html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head><META http-equiv="Content-Type" content="text/html; charset=utf-8">
<title>Change EWC Barcode Entry (CHGEWCBCDE)</title>
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
</head>
<body bgcolor="white">
<script language="Javascript" src="../rzahg/synch.js" type="text/javascript"></script>
<a name="CHGEWCBCDE.Top_Of_Page"></a>
<h2>Change EWC Barcode Entry (CHGEWCBCDE)</h2>
<table width="100%">
<tr>
<td valign="top" align="left"><b>Where allowed to run: </b>All environments (*ALL)<br>
<b>Threadsafe: </b>No
</td>
<td valign="top" align="right">
<a href="#CHGEWCBCDE.PARAMETERS.TABLE">Parameters</a><br>
<a href="#CHGEWCBCDE.COMMAND.EXAMPLES">Examples</a><br>
<a href="#CHGEWCBCDE.ERROR.MESSAGES">Error messages</a></td>
</tr>
</table>
<div> <a name="CHGEWCBCDE"></a>
<p>The Change Extended Wireless Controller Bar Code Entry (CHGEWCBCDE) command changes a set of bar code group parameters in a extended wireless controller source file member. The bar code group defines the parameters for scanning a particular bar code label. The Portable Transaction Computer (PTC) group specifies the bar code groups that are used to configure the bar code scanner.
</p>
<p><b>Restriction:</b> If the values specified for the INZFILE and INZMBR parameters of this command do not match the values specified for the corresponding parameters of the wireless controller description, extended wireless controller configuration data will not be downloaded to the wireless adapter.
</p>
<p><b>Restriction:</b> To execute this command, the user profile requires *IOSYSCFG special authority.
</p>
<p>
<b>Note: </b>You can use the Change Controller Description (Local Work Station) (CHGCTLLWS) command to view or change values specified for the INZFILE and INZMBR parameters in the wireless controller description.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div>
<h3><a name="CHGEWCBCDE.PARAMETERS.TABLE">Parameters</a></h3>
<table border="1" cellpadding="4" cellspacing="0">
<!-- col1="10" col2="15" col3="30" col4="10" -->
<tr>
<th bgcolor="aqua" valign="bottom" align="left">Keyword</th>
<th bgcolor="aqua" valign="bottom" align="left">Description</th>
<th bgcolor="aqua" valign="bottom" align="left">Choices</th>
<th bgcolor="aqua" valign="bottom" align="left">Notes</th>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.BCDGRP"><b>BCDGRP</b></a></td>
<td valign="top">Barcode group</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Required, Key, Positional 1</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.INZMBR"><b>INZMBR</b></a></td>
<td valign="top">Initialization source member</td>
<td valign="top"><i>Name</i></td>
<td valign="top">Required, Key, Positional 2</td>
</tr>
<tr>
<td valign="top" rowspan="3"><a href="#CHGEWCBCDE.INZFILE"><b>INZFILE</b></a></td>
<td valign="top">Initialization source file</td>
<td valign="top"><i>Qualified object name</i></td>
<td valign="top" rowspan="3">Optional, Key, Positional 3</td>
</tr>
<tr>
<td valign="top">Qualifier 1: Initialization source file</td>
<td valign="top"><i>Name</i>, <b><u>QEWCSRC</u></b></td>
</tr><tr>
<td valign="top">Qualifier 2: Library</td>
<td valign="top"><i>Name</i>, <b><u>*LIBL</u></b>, *CURLIB</td>
</tr><tr>
<td valign="top"><a href="#CHGEWCBCDE.BCDTYPE"><b>BCDTYPE</b></a></td>
<td valign="top">Barcode type</td>
<td valign="top"><b><u>*SAME</u></b>, *UPC, *EAN, *PLESSEY, *ALPHAPLESSEY, *ISBNPLESSEY, *PUREPLESSEY, *SAINPLESSEY, *UPCA, *UPCE, *EAN8, *EAN13, *CODABAR, *CODE3OF9, *CODE2OF5, *DISCR2OF5, *INTERL2OF5, *INDUST2OF5, *CODE11, *CODE128, *CODE93</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.LBLLEN"><b>LBLLEN</b></a></td>
<td valign="top">Label length</td>
<td valign="top">0-64, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.CHK1DIGIT"><b>CHK1DIGIT</b></a></td>
<td valign="top">First check digit</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.CHK2DIGIT"><b>CHK2DIGIT</b></a></td>
<td valign="top">Second check digit</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.ALLZERO"><b>ALLZERO</b></a></td>
<td valign="top">All zeros</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.ALPHADSP"><b>ALPHADSP</b></a></td>
<td valign="top">Alpha display</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.ADDON2"><b>ADDON2</b></a></td>
<td valign="top">Add on 2</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.ADDON5"><b>ADDON5</b></a></td>
<td valign="top">Add on 5</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.SYS1UPCE"><b>SYS1UPCE</b></a></td>
<td valign="top">System 1 UPC-E</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.SYS0UPCE"><b>SYS0UPCE</b></a></td>
<td valign="top">System 0 UPC-E</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.UPCE"><b>UPCE</b></a></td>
<td valign="top">UPC-E</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.EAN13"><b>EAN13</b></a></td>
<td valign="top">EAN 13</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.EXT3OF9"><b>EXT3OF9</b></a></td>
<td valign="top">Extended Character Set</td>
<td valign="top"><b><u>*SAME</u></b>, *NO, *YES</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.ADDON"><b>ADDON</b></a></td>
<td valign="top">Add on</td>
<td valign="top"><b><u>*SAME</u></b>, *BIDIRECTIONAL, *FORWARD</td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.DROPBEGIN"><b>DROPBEGIN</b></a></td>
<td valign="top">Drop begin</td>
<td valign="top">0-64, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.DROPEND"><b>DROPEND</b></a></td>
<td valign="top">Drop end</td>
<td valign="top">0-64, <b><u>*SAME</u></b></td>
<td valign="top">Optional</td>
</tr>
<tr>
<td valign="top"><a href="#CHGEWCBCDE.TEXT"><b>TEXT</b></a></td>
<td valign="top">Text 'description'</td>
<td valign="top"><i>Character value</i>, <b><u>*SAME</u></b>, *BLANK</td>
<td valign="top">Optional</td>
</tr>
</table>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
</div>
<div> <a name="CHGEWCBCDE.BCDGRP"></a>
<h3>Barcode group (BCDGRP)</h3>
<p>Specifies the name of the existing bar code group to be changed. This name is used to identify configuration data related to a bar code group. The bar code group name is a unique alphanumeric character string with a maximum of 16 characters in length.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.INZMBR"></a>
<h3>Initialization source member (INZMBR)</h3>
<p>Specifies the extended wireless controller source file member of the bar code group. This member contains the bar code configuration data that is changing.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.INZFILE"></a>
<h3>Initialization source file (INZFILE)</h3>
<p>Specifies the name of the source physical file that contains the extended wireless controller source file member. If the source physical file does not exist, this command will fail.
</p>
<p>The name of the source file can be qualified by one of the following library values:
</p>
<dl>
<dt><b><u>*LIBL</u></b></dt>
<dd>All libraries in the job's library list are searched until the first match is found.
</dd>
<dt><b>*CURLIB</b></dt>
<dd>The current library for the job is searched. If no library is specified as the current library for the job, the QGPL library is used.
</dd>
<dt><b><i>library-name</i></b></dt>
<dd>Specify the name of the library to be searched.
</dd>
</dl>
<p>The possible values are:
</p>
<dl>
<dt><b><u>QEWCSRC</u></b></dt>
<dd>The source file name QEWCSRC is used.
</dd>
<dt><b><i>source-file-name</i></b></dt>
<dd>Specify the name of the source physical file that contains the source member.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.BCDTYPE"></a>
<h3>Barcode type (BCDTYPE)</h3>
<p>Specifies the bar code type defined by this bar code group.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*UPC</b></dt>
<dd>UPC bar codes are used.
</dd>
<dt><b>*EAN</b></dt>
<dd>EAN bar codes are used.
</dd>
<dt><b>*PLESSEY</b></dt>
<dd>Plessey bar codes are used.
</dd>
<dt><b>*ALPHAPLESSEY</b></dt>
<dd>Alpha Plessey bar codes are used.
</dd>
<dt><b>*ISBNPLESSEY</b></dt>
<dd>ISBN Plessey bar codes are used.
</dd>
<dt><b>*PUREPLESSEY</b></dt>
<dd>Pure Plessey bar codes are used.
</dd>
<dt><b>*SAINPLESSEY</b></dt>
<dd>Sainsbury Plessey bar codes are used.
</dd>
<dt><b>*UPCA</b></dt>
<dd>UPC-A bar codes are used.
</dd>
<dt><b>*UPCE</b></dt>
<dd>UPC-E bar codes are used.
</dd>
<dt><b>*EAN8</b></dt>
<dd>EAN-8 bar codes are used.
</dd>
<dt><b>*EAN13</b></dt>
<dd>EAN-13 bar codes are used.
</dd>
<dt><b>*CODABAR</b></dt>
<dd>CODABAR bar codes are used.
</dd>
<dt><b>*CODE3OF9</b></dt>
<dd>CODE 3 of 9 bar codes are used.
</dd>
<dt><b>*CODE2OF5</b></dt>
<dd>CODE 2 of 5 bar codes are used.
</dd>
<dt><b>*DISCR2OF5</b></dt>
<dd>Discrete 2 of 5 bar codes are used.
</dd>
<dt><b>*INTERL2OF5</b></dt>
<dd>Interleaved 2 of 5 bar codes are used.
</dd>
<dt><b>*INDUST2OF5</b></dt>
<dd>Industrial 2 of 5 bar codes are used.
</dd>
<dt><b>*CODE11</b></dt>
<dd>CODE 11 bar codes are used.
</dd>
<dt><b>*CODE128</b></dt>
<dd>CODE 128 bar codes are used.
</dd>
<dt><b>*CODE93</b></dt>
<dd>CODE 93 bar codes are used.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.LBLLEN"></a>
<h3>Label length (LBLLEN)</h3>
<p>Specifies the label length of a bar code label for the specified bar code group.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b><i>label-length</i></b></dt>
<dd>Specify the character length of a bar code label for the bar code group. If the label length is 00 then label length is variable from 1 to 64. The valid range of values is from 0 through 64.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.CHK1DIGIT"></a>
<h3>First check digit (CHK1DIGIT)</h3>
<p>Specifies whether the check digit or the first check digit are checked on the bar code label. This is valid only when *PLESSEY, *CODE3OF9, *EXTCODE3OF9, *CODE11, or *CODE2OF5 are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>The check digit or the first check digit are ignored.
</dd>
<dt><b>*YES</b></dt>
<dd>The check digit or the first check digit are checked for a valid read.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.CHK2DIGIT"></a>
<h3>Second check digit (CHK2DIGIT)</h3>
<p>Specifies whether the second check digit is checked on the bar code label. This is valid only when *PLESSEY or *CODE11 are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>The second check digit is ignored.
</dd>
<dt><b>*YES</b></dt>
<dd>The second check digit is checked for a valid read.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.ALLZERO"></a>
<h3>All zeros (ALLZERO)</h3>
<p>Specifies whether a bar code label of all 0's is a valid scan. This is valid only when BCDTYPE(*PLESSEY) is specified.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>A bar code label of all 0's is not a valid scan.
</dd>
<dt><b>*YES</b></dt>
<dd>A bar code label of all 0's is a valid scan.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.ALPHADSP"></a>
<h3>Alpha display (ALPHADSP)</h3>
<p>Specifies whether to display bar code label characters : ; &lt; = &gt; and ? as alphabetic characters A, B, C, D, E and F, respectively. This is valid only when BCDTYPE(*PLESSEY) is specified.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>Display the characters normally.
</dd>
<dt><b>*YES</b></dt>
<dd>Display the characters as alphabetic characters.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.ADDON2"></a>
<h3>Add on 2 (ADDON2)</h3>
<p>Specifies whether a 2-digit add on is valid or ignored. This is valid only when *UPC or *EAN are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>A 2-digit add on is ignored.
</dd>
<dt><b>*YES</b></dt>
<dd>A 2-digit add on is valid.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.ADDON5"></a>
<h3>Add on 5 (ADDON5)</h3>
<p>Specifies whether 5-digit add on is valid or ignored. This is valid only when *UPC or *EAN are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>A 5-digit add on is ignored.
</dd>
<dt><b>*YES</b></dt>
<dd>A 5-digit add on is valid.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.SYS1UPCE"></a>
<h3>System 1 UPC-E (SYS1UPCE)</h3>
<p>Specifies whether a System 1 UPC-E is valid or ignored. This is valid only when *UPC or *EAN are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>A System 1 UPC-E is ignored.
</dd>
<dt><b>*YES</b></dt>
<dd>A System 1 UPC-E is valid.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.SYS0UPCE"></a>
<h3>System 0 UPC-E (SYS0UPCE)</h3>
<p>Specifies whether a system 0 UPC-E is valid or ignored. This is valid only when *UPC or *EAN are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>A System 0 UPC-E is ignored.
</dd>
<dt><b>*YES</b></dt>
<dd>A System 0 UPC-E is valid.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.UPCE"></a>
<h3>UPC-E (UPCE)</h3>
<p>Specifies whether a UPC-E should be expanded to a UPC-A. This is valid only when *UPC or *EAN are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>UPC-E bar codes are unaffected.
</dd>
<dt><b>*YES</b></dt>
<dd>UPC-E bar codes are expanded to UPC-A.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.EAN13"></a>
<h3>EAN 13 (EAN13)</h3>
<p>Specifies whether UPC and EAN bar codes are expanded to EAN-13. This is valid only when *UPC or *EAN are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*NO</b></dt>
<dd>UPC and EAN bar codes are unaffected.
</dd>
<dt><b>*YES</b></dt>
<dd>UPC and EAN bar codes are expanded to EAN-13.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.EXT3OF9"></a>
<h3>Extended Character Set (EXT3OF9)</h3>
<p>Specifies whether code 3 of 9 bar code uses the extended character set. This is valid only when *CODE3OF9 is specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b><u>*NO</u></b></dt>
<dd>Code 3 of 9 bar code is unaffected.
</dd>
<dt><b>*YES</b></dt>
<dd>Code 3 of 9 bar code uses the extended character set.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.ADDON"></a>
<h3>Add on (ADDON)</h3>
<p>Specifies the direction of add on digits. This is valid only when *UPC or *EAN are specified by the BCDTYPE parameter.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*BIDIRECTIONAL</b></dt>
<dd>Add on digits are valid in both directions.
</dd>
<dt><b>*FORWARD</b></dt>
<dd>Add on digits are valid only in the forward direction.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.DROPBEGIN"></a>
<h3>Drop begin (DROPBEGIN)</h3>
<p>Specifies the number of characters to drop from the beginning of the bar code label. The valid range of values is from 0 through 64.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b><i>drop-begin</i></b></dt>
<dd>Specify the number of characters to drop from the beginning of the bar code label. The valid range of values is from 0 through 64.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.DROPEND"></a>
<h3>Drop end (DROPEND)</h3>
<p>Specifies the number of characters to drop from the end of the bar code label. The valid range of values is from 0 through 64.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b><i>drop-end</i></b></dt>
<dd>Specify the number of characters to drop from the end of the bar code label. The valid range of values is from 0 through 64.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<div> <a name="CHGEWCBCDE.TEXT"></a>
<h3>Text 'description' (TEXT)</h3>
<p>Specifies text that briefly describes the PTC entry.
</p>
<p>The possible values are:
</p>
<dl>
<dt><b><u>*SAME</u></b></dt>
<dd>The value remains the same.
</dd>
<dt><b>*BLANK</b></dt>
<dd>Text is not specified.
</dd>
<dt><b><i>'description'</i></b></dt>
<dd>Specify no more than 50 characters of text, enclosed in apostrophes.
</dd>
</dl>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div><h3><a name="CHGEWCBCDE.COMMAND.EXAMPLES">Examples</a> </h3>
<p>
<pre>
CHGEWCBCDE BCDGRP(BCD01) INZMBR(EWC01) ADDON2(*YES)
</pre>
</p>
<p>This command changes a bar code group named BCD01 to allow ADDON2 usage in an extended wireless controller configuration source file member named EWC01 in source physical file QEWCSRC in the library list.
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
<hr size="2" width="100%">
<div><h3><a name="CHGEWCBCDE.ERROR.MESSAGES">Error messages</a> </h3>
<p>None
</p>
</div>
<table width="100%">
<tr><td align="right"><a href="#CHGEWCBCDE.Top_Of_Page">Top</a></td></tr>
</table>
</body>