ibm-information-center/dist/eclipse/plugins/i5OS.ic.apis_5.4.0.1/QsnWrtPad.htm

402 lines
12 KiB
HTML
Raw Permalink Normal View History

2024-04-02 14:02:31 +00:00
<!DOCTYPE html PUBLIC "-//W3C//DTD HTML 4.01 Transitional//EN">
<html>
<head>
<meta http-equiv="Content-Type" content="text/html; charset=utf-8">
<meta name="Copyright" content="Copyright (c) 2006 by IBM Corporation">
<title>Pad for N Positions (QsnWrtPad) API</title>
<!-- Begin Header Records ========================================== -->
<!-- All rights reserved. Licensed Materials Property of IBM -->
<!-- US Government Users Restricted Rights -->
<!-- Use, duplication or disclosure restricted by -->
<!-- GSA ADP Schedule Contract with IBM Corp. -->
<!-- DSMMST1 SCRIPT A converted by B2H R4.1 (346) (CMS) by V2KEA304 -->
<!-- at RCHVMW2 on 29 Jan 1999 at 16:05:09 -->
<!-- Change History: -->
<!-- YYMMDD USERID Change description -->
<!--File Edited October 2001 -->
<!--End Header Records -->
<link rel="stylesheet" type="text/css" href="../rzahg/ic.css">
</head>
<body>
<a name="top_Of_Page"></a>
<!-- Java sync-link -->
<script language="Javascript" src="../rzahg/synch.js" type="text/javascript">
</script>
<h2>Pad for N Positions (QsnWrtPad) API</h2>
<div class="box" style="width: 70%;">
<br>
&nbsp;&nbsp;Required Parameter Group:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%">1</td>
<td align="left" valign="top" width="50%">Pad character</td>
<td align="left" valign="top" width="20%">Input</td>
<td align="left" valign="top" width="20%">Char(1)</td>
</tr>
<tr>
<td align="center" valign="top">2</td>
<td align="left" valign="top">Number of bytes</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Omissible Parameter Group:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%">3</td>
<td align="left" valign="top" width="50%">Field ID</td>
<td align="left" valign="top" width="20%">Input</td>
<td align="left" valign="top" width="20%">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">4</td>
<td align="left" valign="top">From row</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">5</td>
<td align="left" valign="top">From column</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">6</td>
<td align="left" valign="top">Command buffer handle</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">7</td>
<td align="left" valign="top">Low-level environment handle</td>
<td align="left" valign="top">Input</td>
<td align="left" valign="top">Binary(4)</td>
</tr>
<tr>
<td align="center" valign="top">8</td>
<td align="left" valign="top">Error code</td>
<td align="left" valign="top">I/O</td>
<td align="left" valign="top">Char(*)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Returned Value:<br>
<!-- iddvc RMBR -->
<br>
<table width="100%">
<tr>
<td align="center" valign="top" width="10%"></td>
<td align="left" valign="top" width="50%">Return code</td>
<td align="left" valign="top" width="20%">Output</td>
<td align="left" valign="top" width="20%">Binary(4)</td>
</tr>
</table>
<br>
&nbsp;&nbsp;Default Public Authority: *USE<br>
<!-- iddvc RMBR -->
<br>
&nbsp;&nbsp;Service Program: QSNAPI<br>
<!-- iddvc RMBR -->
<br>
&nbsp;&nbsp;Threadsafe: No<br>
<!-- iddvc RMBR -->
<br>
</div>
<p>The Pad for N Positions (QsnWrtPad) API pads the display with the given pad
character for the specified number of bytes. Padding starts at the row and
column specified, or at the current display address if these parameters are
omitted. To allow the QsnWrtPad operation to insert a group of characters
without overwriting the ending screen attribute, the following conditions must
be satisfied:</p>
<ul>
<li>The operation is an indirect operation.</li>
<li>The row and column parameters are omitted.</li>
<li>The low-level environment description does not indicate that DBCS data is
being used.</li>
<li>The previous command saved in the command buffer was a Write Data
(QsnWrtDta) operation.</li>
</ul>
<p>If the row and column parameters are omitted and the command is either a
direct operation or the buffer specified does not contain a preceding output
operation that sets the display address, then the current display address is
set to row 1, column 1, prior to writing the pad characters.</p>
<p>If the from-row and from-column parameters are specified, this command
corresponds indirectly to the 5250 Write to Display (WTD) command with a Set
Buffer Address order. (For an indirect operation, a WTD is placed in the
command buffer only if one does not already exist in the buffer.)</p>
<br>
<h3>Authorities and Locks</h3>
<p>None</p>
<br>
<h3>Restrictions</h3>
<p>The same restrictions apply as for the Write Data (QsnWrtDta) API.</p>
<br>
<h3>Required Parameter Group</h3>
<dl>
<dt><strong>Pad character</strong></dt>
<dd>INPUT; CHAR(1)
<p>The pad character to pad the screen with.</p>
</dd>
<dt><strong>Number of bytes</strong></dt>
<dd>INPUT; BINARY(4)
<p>The number of bytes to pad the screen for.</p>
</dd>
</dl>
<br>
<h3>Omissible Parameter Group</h3>
<dl>
<dt><strong>Field ID</strong></dt>
<dd>INPUT; BINARY(4)
<p>The field ID indicating the field at which to set the display address. If
this parameter is specified with a nonzero value, the row and column parameters
are ignored and the row and column values corresponding to the field ID are
used to set the display address. If neither the field ID or row and column
parameters are specified, the current display address is used.</p>
</dd>
<dt><strong>From row</strong></dt>
<dd>INPUT; BINARY(4)
<p>The row at which to write the first pad character. The row parameter must
refer to a row no greater than the current screen or window mode height (if
window mode is enabled). The actual screen row used for a screen I/O operation
is calculated using the formula base+offset=actual. The base is the row
location of the top window border (0 for full screen) if offset is positive, or
the row location of the bottom window border (screen height plus 1 for full
screen) if offset is negative. The offset is the row parameter value specified,
and actual is the actual screen row to be used. A CPFA307 error occurs if an
incorrect row value is specified.</p>
<p>If both the from-row and from-column parameters are omitted, the pad
characters are written starting at the current display address. If this is the
case and the command is a direct operation, or the buffer specified does not
contain a preceding output operation that sets the display address, the current
display address is set to row 1, column 1, prior to writing the pad characters.
Both the from-row and from-column parameters must be specified, or both
parameters must be omitted.</p>
</dd>
<dt><strong>From column</strong></dt>
<dd>INPUT; BINARY(4)
<p>The column at which to write the first pad character. The column parameter
must refer to a column no greater than the current screen or window mode width
(if window mode is on). The actual screen column used for a screen I/O
operation is calculated using the formula base+offset=actual. The base is the
column location of the left window border (0 for full screen) if offset is
positive, or the column location of the center window border (screen width plus
1 for full screen) if offset is negative. The offset is the column parameter
value specified, and actual is the actual screen column to be used. A CPFA307
error occurs if an incorrect column value is specified.</p>
</dd>
<dt><strong>Command buffer handle</strong></dt>
<dd>INPUT; BINARY(4)
<p>A handle for the command buffer in which to store the command. If this
parameter is omitted or specified as 0, this is a direct operation and the pad
characters are written to the screen at the current display address. Otherwise,
this is an indirect operation and the command is stored in the command buffer
without an I/O operation taking place.</p>
</dd>
<dt><strong>Low-level environment handle</strong></dt>
<dd>INPUT; BINARY(4)
<p>The low-level environment that the operation applies to. If this parameter
is omitted or given with a value of zero, the default low-level environment is
used.</p>
</dd>
<dt><strong>Error code</strong></dt>
<dd>I/O; CHAR(*)
<p>The structure in which to return error information. For the format of the
structure, see <a href="../apiref/error.htm#hdrerrcod">Error Code Parameter</a>. If this
parameter is omitted, diagnostic and escape messages are issued to the
application.</p>
</dd>
</dl>
<br>
<h3>Returned Value</h3>
<dl>
<dt><strong>Return code</strong></dt>
<dd>OUTPUT; BINARY(4)
<p>A return code indicating the result of the operation. The value returned
will be 0 if the operation was successful, or -1 otherwise.</p>
</dd>
</dl>
<br>
<h3>Error Messages</h3>
<table width="100%" cellpadding="3">
<!-- cols="15 85" -->
<tr>
<th align="left" valign="top">Message ID</th>
<th align="left" valign="top">Error Message Text</th>
</tr>
<tr>
<td align="left" valign="top">CPF24B4 E</td>
<td valign="top">Severe error while addressing parameter list.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3CF1 E</td>
<td valign="top">Error code parameter not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPF3CF2 E</td>
<td valign="top">Error(s) occurred during running of &amp;1 API.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA301 E</td>
<td valign="top">Command buffer is full.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA303 E</td>
<td valign="top">Error occurred for screen I/O operation.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA304 E</td>
<td valign="top">Data-stream error &amp;1 reported for screen I/O
operation.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA305 E</td>
<td valign="top">Cannot add operation to command buffer.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA307 E</td>
<td valign="top">Screen position &amp;1, &amp;2 outside of display or window
area.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA308 E</td>
<td valign="top">Attempt to write data past end of display.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA31D E</td>
<td valign="top">Attempt to write outside of window area.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA31E E</td>
<td valign="top">Required parameter &amp;1 omitted.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA331 E</td>
<td valign="top">Buffer handle incorrect.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA333 E</td>
<td valign="top">Parameter &amp;1 not positive integer value.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA334 E</td>
<td valign="top">Low level environment handle incorrect.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA335 E</td>
<td valign="top">Screen address parameter error.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA33C E</td>
<td valign="top">Undefined field ID &amp;1.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA343 E</td>
<td valign="top">Output operation not done.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA344 E</td>
<td valign="top">The file &amp;2 in library &amp;3 is not valid.</td>
</tr>
<tr>
<td align="left" valign="top">CPFA345 E</td>
<td valign="top">The invite active flag is not valid.</td>
</tr>
</table>
<br>
<hr>
API introduced: V2R3
<hr>
<center>
<table cellpadding="2" cellspacing="2">
<tr align="center">
<td valign="middle" align="center"><a href="#Top_Of_Page">Top</a> | <a href=
"dsm.htm">Dynamic Screen Manager APIs</a> | <a href="aplist.htm">APIs by
category</a></td>
</tr>
</table>
</center>
</body>
</html>